Literature DB >> 30528644

Gross visual inspection by endosonographers during endoscopic ultrasound-guided fine needle aspiration.

Hirotoshi Ishiwatari1, Junya Sato2, Shinya Fujie2, Keiko Sasaki3, Junichi Kaneko2, Tatsunori Satoh2, Hiroyuki Matsubayashi2, Yoshihiro Kishida2, Masao Yoshida2, Sayo Ito2, Noboru Kawata2, Kenichiro Imai2, Naomi Kakushima2, Kohei Takizawa2, Kinichi Hotta2, Hiroyuki Ono2.   

Abstract

BACKGROUND/
OBJECTIVES: A clear criterion for terminating endoscopic ultrasound fine needle aspiration (EUS-FNA) without rapid on-site evaluation (ROSE) has not been established. However, a possible solution includes gross visual inspection (GVI) of the sample obtained with EUS-FNA. We performed a retrospective study to elucidate the efficacy of GVI for the diagnostic yield of EUS-FNA.
METHODS: Patients who underwent EUS-FNA of a pancreatic mass using a standard 22-G needle from January 2017 to December 2017 were included in the study. At least two punctures were performed for each patient, and GVI was performed for each pass by endoscopists. The correlation between GVI and pathological findings were investigated per needle pass for the first two passes. Regarding GVI, we evaluated the presence of a visible core (with or without) and the sample quantity (large or small).
RESULTS: We evaluated 126 EUS-FNA specimens and analyzed 252 needle passes. A final diagnosis of malignancy was made for 119 patients (94%). Accuracy rates were 92.5% with a visible core and 70.0% without a visible core (p < 0.01), and 85.2% for large sample quantities and 70.2% for small sample quantities (p < 0.01). Univariate analysis indicated that the presence of a visible core and large sample quantity were associated with accuracy. Multivariate analysis indicated that only the presence of a visible core was significant.
CONCLUSIONS: GVI can predict the correct diagnosis when ROSE is unavailable. Evaluating the presence of a visible core is more sensitive than assessing the quantity of the sample obtained.
Copyright © 2018 IAP and EPC. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Endoscopic ultrasound; Fine needle aspiration; Gross visual inspection; Needle

Mesh:

Year:  2018        PMID: 30528644     DOI: 10.1016/j.pan.2018.12.001

Source DB:  PubMed          Journal:  Pancreatology        ISSN: 1424-3903            Impact factor:   3.996


  7 in total

1.  Usefulness of the automated multiband imaging system for EUS-FNA biopsy specimen evaluation in patients with upper gastrointestinal subepithelial lesions.

Authors:  Kosuke Okuwaki; Hiroshi Imaizumi; Mitsuhiro Kida; Hironori Masutani; Tomohisa Iwai; Masafumi Watanabe; Kai Adachi; Masayoshi Tadehara; Rikiya Hasegawa; Seigo Nakatani; Takahiro Kurosu; Akihiro Tamaki; Wasaburo Koizumi
Journal:  Endosc Ultrasound       Date:  2022-03-21       Impact factor: 5.275

2.  The impact of macroscopic on-site evaluation using filter paper in EUS-guided fine-needle biopsy.

Authors:  Dongwook Oh; Dong-Wan Seo; Seung-Mo Hong; Tae Jun Song; Do Hyun Park; Sang Soo Lee; Sung Koo Lee; Myung-Hwan Kim
Journal:  Endosc Ultrasound       Date:  2019 Sep-Oct       Impact factor: 5.628

3.  A Pancreatic Inflammatory Myofibroblastic Tumor with Spontaneous Remission: A Case Report with a Literature Review.

Authors:  Hiroyuki Matsubayashi; Katsuhiko Uesaka; Keiko Sasaki; Seitaro Shimada; Kazunori Takada; Hirotoshi Ishiwatari; Hiroyuki Ono
Journal:  Diagnostics (Basel)       Date:  2019-10-17

4.  Confirming Whether Fine Needle Biopsy Device Shortens the Learning Curve of Endoscopic Ultrasound-Guided Tissue Acquisition Without Rapid Onsite Evaluation.

Authors:  Meng-Ying Lin; Cheng-Lin Wu; Mitsuhiro Kida; Wei-Lun Chang; Bor-Shyang Sheu
Journal:  Clin Endosc       Date:  2021-05-28

5.  New image-processing technology for endoscopic ultrasound-guided fine-needle aspiration biopsy specimen evaluation in patients with pancreatic cancer.

Authors:  Kosuke Okuwaki; Hiroshi Imaizumi; Mitsuhiro Kida; Hironori Masutani; Masafumi Watanabe; Kai Adachi; Masayoshi Tadehara; Akihiro Tamaki; Tomohisa Iwai; Hiroshi Yamauchi; Rikiya Hasegawa; Toru Kaneko; Takahiro Kurosu; Wasaburo Koizumi
Journal:  DEN open       Date:  2021-06-09

6.  Tumor Location in the Head/Uncinate Process and Presence of Fibrosis Impair the Adequacy of Endoscopic Ultrasound-Guided Tissue Acquisition of Solid Pancreatic Tumors.

Authors:  Thomas Togliani; Andrea Lisotti; Rosa Rinaldi; Adele Fornelli; Stefano Pilati; Nicola Passigato; Pietro Fusaroli
Journal:  Cancers (Basel)       Date:  2022-07-21       Impact factor: 6.575

7.  Macroscopic on-site evaluation of biopsy specimens for accurate pathological diagnosis during EUS-guided fine needle biopsy using 22-G Franseen needle.

Authors:  Junichi Kaneko; Hirotoshi Ishiwatari; Keiko Sasaki; Tatsunori Satoh; Junya Sato; Hiroyuki Matsubayashi; Yohei Yabuuchi; Yoshihiro Kishida; Masao Yoshida; Sayo Ito; Noboru Kawata; Kenichiro Imai; Naomi Kakushima; Kohei Takizawa; Kinichi Hotta; Hiroyuki Ono
Journal:  Endosc Ultrasound       Date:  2020 Nov-Dec       Impact factor: 5.628

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.