Literature DB >> 30524582

Serial angiographic and endovascular documentation of peri-stent contrast stains after sirolimus-eluting stent implantation: Multiple cavity formations between entirely covered stent struts.

Yoshihiro Morino1, Takayuki Iida1, Masataka Ishii1, Naoki Masuda1, Takashi Matuskage1, Nobuhiko Ogata1, Teruhisa Tanabe1, Yuji Ikari1.   

Abstract

A 72-year-old woman with a history of treatment with a single sirolimus-eluting stent (SES) for right coronary artery stenosis 21 months previously, was hospitalized to undertake invasive coronary evaluation due to recurrence of symptoms of effort angina. At the time of 9 months of angiographic follow-up, no in-stent restenosis was detected, however, several contrast filled "dimples" were noticed outside the stent border. At this time, further increments in the numbers of dimple formation were documented, in addition to progression of stenosis at the distal non-stented portion. Intravascular ultrasound demonstrated multiple cavity formations between the stent struts, due to positive remodeling occurring at the previously relatively disease-free side of the vessel wall. Surprisingly, optical coherence tomography demonstrated all the stent struts, including those located adjacent to cavities, were exclusively covered with neointima or other tissue components, completely attaching to the vessel wall throughout the stented segment. No evident thrombus formation was detected in these cavities. Despite no exposed stent struts, a hypothetical concern remains because such cul-de-sac formations may produce local blood flow turbulence within stents, which may be potentially associated with activation of local platelet aggregation. Careful long-term follow-up may be necessary for these patients.

Entities:  

Keywords:  Intravascular ultrasound; Optical coherence tomography; Stent; Thrombosis

Year:  2010        PMID: 30524582      PMCID: PMC6264968          DOI: 10.1016/j.jccase.2009.12.006

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


  6 in total

1.  Images in Cardiovascular Medicine. True three-dimensional reconstructed images showing lumen enlargement after sirolimus-eluting stent implantation.

Authors:  Kengo Tanabe; Frank J H Gijsen; Muzaffer Degertekin; Jurgen M R Ligthart; Remko M Oortman; Patrick W Serruys; Cornelis J Slager
Journal:  Circulation       Date:  2002-11-26       Impact factor: 29.690

2.  Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis.

Authors:  Junya Ako; Yoshihiro Morino; Yasuhiro Honda; Ali Hassan; Shinjo Sonoda; Paul G Yock; Martin B Leon; Jeffrey W Moses; Heidi N Bonneau; Peter J Fitzgerald
Journal:  J Am Coll Cardiol       Date:  2005-09-20       Impact factor: 24.094

3.  Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation.

Authors:  Stéphane Cook; Peter Wenaweser; Mario Togni; Michael Billinger; Cyrill Morger; Christian Seiler; Rolf Vogel; Otto Hess; Bernhard Meier; Stephan Windecker
Journal:  Circulation       Date:  2007-05-08       Impact factor: 29.690

4.  [Frequency and characteristics of incomplete stent apposition during and after sirolimus-eluting stent implantation].

Authors:  Hiroki Takeuchi; Yoshihiro Morino; Daisuke Fujibayashi; Tadashi Hashida; Yota Kawamura; Naoko Tsumuraya; Nami Okamoto; Masakazu Nagaoka; Yuji Ikari; Teruhisa Tanabe
Journal:  J Cardiol       Date:  2007-08       Impact factor: 3.159

5.  A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.

Authors:  Marie-Claude Morice; Patrick W Serruys; J Eduardo Sousa; Jean Fajadet; Ernesto Ban Hayashi; Marco Perin; Antonio Colombo; G Schuler; Paul Barragan; Giulio Guagliumi; Ferenc Molnàr; Robert Falotico
Journal:  N Engl J Med       Date:  2002-06-06       Impact factor: 91.245

6.  Very late thrombosis of sirolimus-eluting stent due to late malapposition: serial observations with optical coherence tomography.

Authors:  Takahiro Sawada; Junya Shite; Toshiro Shinke; Yusuke Tanino; Daisuke Ogasawara; Hiroyuki Kawamori; Hiroki Kato; Naoki Miyoshi; Naoki Yoshino; Ken-Ichi Hirata
Journal:  J Cardiol       Date:  2008-07-17       Impact factor: 3.159

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.