Very late thrombosis of sirolimus-eluting stent due to late malapposition: serial observations with optical coherence tomography.

Takahiro Sawada1, Junya Shite, Toshiro Shinke, Yusuke Tanino, Daisuke Ogasawara, Hiroyuki Kawamori, Hiroki Kato, Naoki Miyoshi, Naoki Yoshino, Ken-Ichi Hirata.   

Abstract

A 54 years old man underwent directional coronary atherectomy in segment 7 with a partial deep-cut injury. A sirolimus-eluting stent (SES) was implanted at the restenosed post-atherectomy lesion. Six months after SES implantation, intravascular ultrasound (IVUS) examination revealed slight vessel enlargement although there were no malapposed struts. Optical coherence tomography (OCT) revealed partial stent malapposition. Ticlopidine was discontinued 3 months after SES implantation, but aspirin was continued. Twenty-nine months after SES implantation, after discontinuing aspirin for 7 days for colon polypectomy, the patient suffered an acute myocardial infarction at the SES implantation site. IVUS revealed further positive vessel remodeling and slight stent malapposition and OCT revealed extension of the previous stent malapposition and ulcer-like appearance around the stent struts. This case demonstrates that even a small partial SES malapposition that can be detected only by OCT has the potential to enlarge over time and the late malapposition may result in late thrombosis when anti-platelet therapy is discontinued.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19027609     DOI: 10.1016/j.jjcc.2008.05.003

Source DB:  PubMed          Journal:  J Cardiol        ISSN: 0914-5087            Impact factor:   3.159


  6 in total

1.  Neointimal tissue characteristics following sirolimus-eluting stent implantation: OCT quantitative tissue property analysis.

Authors:  Jingbo Hou; Haibo Jia; Haixia Liu; Zhigang Han; Shuang Yang; Chenyang Xu; Joseph Schmitt; Shaosong Zhang; Bo Yu; Ik-Kyung Jang
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-16       Impact factor: 2.357

2.  Very late stent thrombosis predicted by multislice computed tomography.

Authors:  Yoshimitsu Tanaka; Ki-Ichiro Tomiyasu; Satoshi Akabame; Muhei Tanaka; Koji Nakano
Journal:  J Cardiol Cases       Date:  2010-11-19

3.  Recurrent very late thrombosis of drug-eluting stent: Optical coherence tomography findings.

Authors:  Nobuaki Kobayashi; Masamichi Takano; Noritake Hata; Masanori Yamamoto; Takuro Shinada; Yasuhiro Takahashi; Kazunori Tomita; Mitsunobu Kitamura; Osamu Kurihara; Kyoichi Mizuno
Journal:  J Cardiol Cases       Date:  2010-08-10

4.  Intravascular Ultrasound Versus Optical Coherence Tomography for Coronary Artery Imaging - Apples and Oranges?

Authors:  Krishnaraj S Rathod; Stephen M Hamshere; Daniel A Jones; Anthony Mathur
Journal:  Interv Cardiol       Date:  2015-03

5.  Serial angiographic and endovascular documentation of peri-stent contrast stains after sirolimus-eluting stent implantation: Multiple cavity formations between entirely covered stent struts.

Authors:  Yoshihiro Morino; Takayuki Iida; Masataka Ishii; Naoki Masuda; Takashi Matuskage; Nobuhiko Ogata; Teruhisa Tanabe; Yuji Ikari
Journal:  J Cardiol Cases       Date:  2010-01-25

6.  Computer Simulation of Platelet Adhesion around Stent Struts in the Presence and Absence of Tissue Defects around Them.

Authors:  Yota Kawamura; Noriko Tamura; Shinichi Goto; Shinya Goto
Journal:  J Interv Cardiol       Date:  2021-02-12       Impact factor: 2.279

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.