Abdul Rehaman1, Anusha Ramesh1, Sanjiv Prajapati1, Ramesh Basavappa1.
Abstract
A 62-year-old female, who had undergone dual chamber pacemaker implantation through left subclavian approach, developed tension pneumothorax of left side. This resulted in shift of entire mediastinum and lead displacement with altered lead parameters. Pacemaker implantation can be complicated by tension pneumothorax in 0.6-5% of cases. Tension pneumothorax can cause mediastinal shift and rarely cause displacement of the leads. In our patient, shift of mediastinum with change of loops and position was associated with change of parameters requiring lead revision. <Learning objective: Pacemaker implantation can be complicated by tension pneumothorax in 0.6-5% of cases. Tension pneumothorax can cause mediastinal shift and rarely cause displacement of the leads. In our patient, shift of mediastinum with change of loops and position was associated with change of parameters requiring lead revision. This clinical scenario is rarely seen and has not been documented before.>.Entities:
Keywords: Lead displacement; Permanent pacemaker implantation; Pneumothorax
Year: 2016 PMID: 30524577 PMCID: PMC6262092 DOI: 10.1016/j.jccase.2016.09.005
Source DB: PubMed Journal: J Cardiol Cases ISSN: 1878-5409