Literature DB >> 30519678

High-Fidelity Modeling of Detector Lag and Gantry Motion in CT Reconstruction.

Steven Tilley1, Alejandro Sisniega1, Jeffrey H Siewerdsen1, J Webster Stayman1.   

Abstract

Detector lag and gantry motion during x-ray exposure and integration both result in azimuthal blurring in CT reconstructions. These effects can degrade image quality both for high-resolution features as well as low-contrast details. In this work we consider a forward model for model-based iterative reconstruction (MBIR) that is sufficiently general to accommodate both of these physical effects. We integrate this forward model in a penalized, weighted, nonlinear least-square style objective function for joint reconstruction and correction of these blur effects. We show that modeling detector lag can reduce/remove the characteristic lag artifacts in head imaging in both a simulation study and physical experiments. Similarly, we show that azimuthal blur ordinarily introduced by gantry motion can be mitigated with proper reconstruction models. In particular, we find the largest image quality improvement at the periphery of the field-of-view where gantry motion artifacts are most pronounced. These experiments illustrate the generality of the underlying forward model, suggesting the potential application in modeling a number of physical effects that are traditionally ignored or mitigated through pre-corrections to measurement data.

Entities:  

Year:  2018        PMID: 30519678      PMCID: PMC6277043     

Source DB:  PubMed          Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr


  12 in total

Review 1.  Breast CT: potential for breast cancer screening and diagnosis.

Authors:  John M Boone; Karen K Lindfors
Journal:  Future Oncol       Date:  2006-06       Impact factor: 3.404

2.  Investigation into the optimal linear time-invariant lag correction for radar artifact removal.

Authors:  Jared Starman; Josh Star-Lack; Gary Virshup; Edward Shapiro; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

3.  Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation.

Authors:  L E Antonuk; Y El-Mohri; J H Siewerdsen; J Yorkston; W Huang; V E Scarpine; R A Street
Journal:  Med Phys       Date:  1997-01       Impact factor: 4.071

4.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; J M Boudry; I A Cunningham
Journal:  Med Phys       Date:  1997-01       Impact factor: 4.071

5.  High-fidelity artifact correction for cone-beam CT imaging of the brain.

Authors:  A Sisniega; W Zbijewski; J Xu; H Dang; J W Stayman; J Yorkston; N Aygun; V Koliatsos; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-01-22       Impact factor: 3.609

6.  A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors.

Authors:  Jared Starman; Josh Star-Lack; Gary Virshup; Edward Shapiro; Rebecca Fahrig
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

7.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

8.  Technical assessment of a prototype cone-beam CT system for imaging of acute intracranial hemorrhage.

Authors:  Jennifer Xu; Alejandro Sisniega; Wojciech Zbijewski; Hao Dang; J Webster Stayman; Michael Mow; Xiaohui Wang; David H Foos; Vassillis E Koliatsos; Nafi Aygun; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

9.  Combining ordered subsets and momentum for accelerated X-ray CT image reconstruction.

Authors:  Donghwan Kim; Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-08-22       Impact factor: 10.048

Review 10.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

View more
  2 in total

1.  Model-based material decomposition with a penalized nonlinear least-squares CT reconstruction algorithm.

Authors:  Steven Tilley; Wojciech Zbijewski; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-01-22       Impact factor: 3.609

2.  Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms.

Authors:  P Wu; A Sisniega; J W Stayman; W Zbijewski; D Foos; X Wang; N Khanna; N Aygun; R D Stevens; J H Siewerdsen
Journal:  Med Phys       Date:  2020-04-03       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.