Literature DB >> 30517649

Integrity of clinical information in computerized order requisitions for diagnostic imaging.

Ronilda Lacson1,2, Romeo Laroya1,2, Aijia Wang1, Neena Kapoor1,2, Daniel I Glazer2,3, Atul Shinagare1,2, Ivan K Ip1,2, Sameer Malhotra4, Keith Hentel5, Ramin Khorasani1,2.   

Abstract

Objective: Assess information integrity (concordance and completeness of documented exam indications from the electronic health record [EHR] imaging order requisition, compared to EHR provider notes), and assess potential impact of indication inaccuracies on exam planning and interpretation.
Methods: This retrospective study, approved by the Institutional Review Board, was conducted at a tertiary academic medical center. There were 139 MRI lumbar spine (LS-MRI) and 176 CT abdomen/pelvis orders performed 4/1/2016-5/31/2016 randomly selected and reviewed by 4 radiologists for concordance and completeness of relevant exam indications in order requisitions compared to provider notes, and potential impact of indication inaccuracies on exam planning and interpretation. Forty each LS-MRI and CT abdomen/pelvis were re-reviewed to assess kappa agreement.
Results: Requisition indications were more likely to be incomplete (256/315, 81%) than discordant (133/315, 42%) compared to provider notes (p < 0.0001). Potential impact of discrepancy between clinical information in requisitions and provider notes was higher for radiologist's interpretation than for exam planning (135/315, 43%, vs 25/315, 8%, p < 0.0001). Agreement among radiologists for concordance, completeness, and potential impact was moderate to strong (Kappa 0.66-0.89). Indications in EHR order requisitions are frequently incomplete or discordant compared to physician notes, potentially impacting imaging exam planning, interpretation and accurate diagnosis. Such inaccuracies could also diminish the relevance of clinical decision support alerts if based on information in order requisitions. Conclusions: Improved availability of relevant documented clinical information within EHR imaging requisition is necessary for optimal exam planning and interpretation.

Mesh:

Year:  2018        PMID: 30517649      PMCID: PMC7647161          DOI: 10.1093/jamia/ocy133

Source DB:  PubMed          Journal:  J Am Med Inform Assoc        ISSN: 1067-5027            Impact factor:   4.497


  36 in total

1.  How IT tools can help improve current protocolling performance gaps.

Authors:  Ramin Khorasani
Journal:  J Am Coll Radiol       Date:  2011-10       Impact factor: 5.532

2.  Application of recently developed computer algorithm for automatic classification of unstructured radiology reports: validation study.

Authors:  Keith J Dreyer; Mannudeep K Kalra; Michael M Maher; Autumn M Hurier; Benjamin A Asfaw; Thomas Schultz; Elkan F Halpern; James H Thrall
Journal:  Radiology       Date:  2004-12-10       Impact factor: 11.105

3.  HIPAA administrative simplification: enforcement. Interim final rule; request for comments.

Authors: 
Journal:  Fed Regist       Date:  2009-10-30

4.  Drug-drug interactions that should be non-interruptive in order to reduce alert fatigue in electronic health records.

Authors:  Shobha Phansalkar; Heleen van der Sijs; Alisha D Tucker; Amrita A Desai; Douglas S Bell; Jonathan M Teich; Blackford Middleton; David W Bates
Journal:  J Am Med Inform Assoc       Date:  2012-09-25       Impact factor: 4.497

5.  Augmenting the impact of technology adoption with financial incentive to improve radiology report signature times.

Authors:  Katherine P Andriole; Luciano M Prevedello; Allen Dufault; Parham Pezeshk; Robert Bransfield; Richard Hanson; Peter M Doubilet; Steven E Seltzer; Ramin Khorasani
Journal:  J Am Coll Radiol       Date:  2010-03       Impact factor: 5.532

6.  Systemic Error in Radiology.

Authors:  Stephen Waite; Jinel Moore Scott; Alan Legasto; Srinivas Kolla; Brian Gale; Elizabeth A Krupinski
Journal:  AJR Am J Roentgenol       Date:  2017-07-25       Impact factor: 3.959

7.  Institutional Pressure to Reduce Report Turnaround Time Is Damaging the Educational Mission.

Authors:  Darel E Heitkamp; Aaron P Kamer; Nicholas A Koontz
Journal:  J Am Coll Radiol       Date:  2017-02-24       Impact factor: 5.532

8.  Some unintended consequences of clinical decision support systems.

Authors:  Joan S Ash; Dean F Sittig; Emily M Campbell; Kenneth P Guappone; Richard H Dykstra
Journal:  AMIA Annu Symp Proc       Date:  2007-10-11

9.  Impact of a real-time computerized duplicate alert system on the utilization of computed tomography.

Authors:  Elliot J Wasser; Luciano M Prevedello; Aaron Sodickson; Wenhong Mar; Ramin Khorasani
Journal:  JAMA Intern Med       Date:  2013-06-10       Impact factor: 21.873

10.  Using structured and unstructured data to identify patients' need for services that address the social determinants of health.

Authors:  Joshua R Vest; Shaun J Grannis; Dawn P Haut; Paul K Halverson; Nir Menachemi
Journal:  Int J Med Inform       Date:  2017-09-20       Impact factor: 4.046

View more
  3 in total

Review 1.  Automated Protocoling for MRI Exams-Challenges and Solutions.

Authors:  Jonas Denck; Oliver Haas; Jens Guehring; Andreas Maier; Eva Rothgang
Journal:  J Digit Imaging       Date:  2022-08-30       Impact factor: 4.903

2.  Can emergency department provider notes help to achieve more dynamic clinical decision support?

Authors:  Justin F Rousseau; Ivan K Ip; Ali S Raja; Jeremiah D Schuur; Ramin Khorasani
Journal:  J Am Coll Emerg Physicians Open       Date:  2020-08-25

Review 3.  The role of artificial intelligence in paediatric cardiovascular magnetic resonance imaging.

Authors:  Andrew M Taylor
Journal:  Pediatr Radiol       Date:  2021-12-22
  3 in total