Literature DB >> 30488309

Template for MR Visualization and Needle Targeting.

Rui Li1, Sheng Xu2, Ivane Bakhutashvili2, Ismail B Turkbey3, Peter Choyke3, Peter Pinto4, Bradford Wood2, Zion T H Tse5,6.   

Abstract

To improve the targeting accuracy and reduce procedure time in magnetic resonance imaging (MRI)-guided procedures, a 3D-printed flexible template was developed. The template was printed using flexible photopolymer resin FLFLGR02 in Form 2 printer® (Formlabs, Inc., Somerville, MA). The flexible material gives the template a unique advantage by allowing it to make close contact with human skin and provide accurate insertion with the help of the newly developed OncoNav software. At the back of the template, there is a grid comprised of circular containers filled with contrast agent. At the front of the template, the guide holes between the containers provide space and angular flexibility for needle insertion. MRI scans are initially used to identify tumor position as well as the template location. The OncoNav software then pre-selects a best guide hole for targeting a specific lesion and suggests insertion depth for the physician A phantom study of 13 insertions in a CT scanner was carried out for assessing needle placement accuracy. The mean total distance error between planned and actual insertion is 2.7 mm, the maximum error was 4.78 mm and standard deviation was 1.1 mm. The accuracy of the OncoNav-assisted and template-guided needle targeting is comparable to the robot-assisted procedure. The proposed template is a low-cost, quickly-deployable and disposable medical device. The presented technology will be further evaluated in prostate cancer patients to quantify its accuracy in needle biopsy.

Entities:  

Keywords:  3D-printed template; MRI-guided procedure; MRI-visible

Mesh:

Year:  2018        PMID: 30488309      PMCID: PMC6570497          DOI: 10.1007/s10439-018-02167-z

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  31 in total

1.  MR imaging-guided prostate biopsy with surgical navigation software: device validation and feasibility.

Authors:  N Hata; M Jinzaki; D Kacher; R Cormak; D Gering; A Nabavi; S G Silverman; A V D'Amico; R Kikinis; F A Jolesz; C M Tempany
Journal:  Radiology       Date:  2001-07       Impact factor: 11.105

2.  MRI-guided biopsy of the prostate increases diagnostic performance in men with elevated or increasing PSA levels after previous negative TRUS biopsies.

Authors:  Aristotelis G Anastasiadis; Matthias P Lichy; Udo Nagele; Markus A Kuczyk; Axel S Merseburger; Joerg Hennenlotter; Stefan Corvin; Karl-Dietrich Sievert; Claus D Claussen; Arnulf Stenzl; Heinz-Peter Schlemmer
Journal:  Eur Urol       Date:  2006-03-24       Impact factor: 20.096

3.  Design of a novel MRI compatible manipulator for image guided prostate interventions.

Authors:  Axel Krieger; Robert C Susil; Cynthia Ménard; Jonathan A Coleman; Gabor Fichtinger; Ergin Atalar; Louis L Whitcomb
Journal:  IEEE Trans Biomed Eng       Date:  2005-02       Impact factor: 4.538

4.  Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner.

Authors:  Robert C Susil; Cynthia Ménard; Axel Krieger; Jonathan A Coleman; Kevin Camphausen; Peter Choyke; Gabor Fichtinger; Louis L Whitcomb; C Norman Coleman; Ergin Atalar
Journal:  J Urol       Date:  2006-01       Impact factor: 7.450

Review 5.  Magnetic resonance-guided prostate interventions.

Authors:  Steven J Haker; Robert V Mulkern; Joseph R Roebuck; Agnieska Szot Barnes; Simon Dimaio; Nobuhiko Hata; Clare M C Tempany
Journal:  Top Magn Reson Imaging       Date:  2005-10

6.  MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results.

Authors:  Dirk Beyersdorff; Axel Winkel; Bernd Hamm; Severin Lenk; Stefan A Loening; Matthias Taupitz
Journal:  Radiology       Date:  2004-12-22       Impact factor: 11.105

7.  Robot-assisted needle placement in open MRI: system architecture, integration and validation.

Authors:  S P DiMaio; S Pieper; K Chinzei; N Hata; S J Haker; D F Kacher; G Fichtinger; C M Tempany; R Kikinis
Journal:  Comput Aided Surg       Date:  2007-01

8.  Systematic transperineal ultrasound-guided template biopsy of the prostate: three-year experience.

Authors:  David M Pinkstaff; Todd C Igel; Steven P Petrou; Gregory A Broderick; Michael J Wehle; Paul R Young
Journal:  Urology       Date:  2005-04       Impact factor: 2.649

9.  Transperineal magnetic resonance image guided prostate biopsy.

Authors:  A V D'Amico; C M Tempany; R Cormack; N Hata; M Jinzaki; K Tuncali; M Weinstein; J P Richie
Journal:  J Urol       Date:  2000-08       Impact factor: 7.450

10.  Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device.

Authors:  K Engelhard; H P Hollenbach; B Kiefer; A Winkel; K Goeb; D Engehausen
Journal:  Eur Radiol       Date:  2006-02-01       Impact factor: 5.315

View more
  2 in total

1.  Kinematic and mechanical modelling of a novel 4-DOF robotic needle guide for MRI-guided prostate intervention.

Authors:  Pradipta Biswas; Hossein Dehghani; Sakura Sikander; Sang-Eun Song
Journal:  Biomed Eng Adv       Date:  2022-05-24

2.  The Feasibility of Using a Smartphone Magnetometer for Assisting Needle Placement.

Authors:  Zhuo Zhao; Sheng Xu; Bradford J Wood; Hongliang Ren; Zion Tsz Ho Tse
Journal:  Ann Biomed Eng       Date:  2019-12-12       Impact factor: 3.934

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.