Literature DB >> 30487024

Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia.

William Ottestad, Jan Ivar Kåsin, Lars Øivind Høiseth.   

Abstract

INTRODUCTION: Clinical accuracy of pulse oximeters (giving Spo₂) is routinely tested down to an Sao₂ of 70%, but lower oxygen saturations are often experienced during hypobaric hypoxia. Cerebral (Sco₂) and peripheral tissue (Sto₂) oxygen saturations can be measured using near infra-red spectroscopy. In a project simulating oxygen system failure during high altitude-high opening parachuting (HAHO), Sao₂, Spo₂, Sco₂, and forearm Sto₂ were measured. The aim of the present analysis was to explore the agreement between Sao₂ and the three noninvasive measurements of hypoxemia (Spo₂, Sco₂, and Sto₂).
METHODS: Healthy volunteers from the Norwegian Special Operations Commando were studied in a hypobaric chamber as supplemental oxygen was removed at 301 hPa ambient pressure (30,000 ft) and recompressed at 25 hPa · min-1 (1000 ft · min-1) to ground level simulating a HAHO parachute flight. Sao₂ was compared with Spo₂, Sco₂, and Sto₂ in scatterplots and Bland-Altman plots, calculating bias and limits of agreement (LOA).
RESULTS: The bias ± LOA were: Sao₂ vs. Spo₂: -5.8% ± 16, Sao₂ vs. Sco₂: -3.4% ± 11, and Sao₂ vs. Sto₂: 17% ± 30. The bias for Sao₂ vs. Spo₂ was dependent on the range of values, and correcting for this with a sloped bias line reduced the LOA to ± 8.2%.DISCUSSION: There were wide limits of agreement between Sao₂ and Spo₂. Sao₂ and Sco₂ agreed better, whereas Sao₂ and forearm Sto₂ had wide LOA. The agreement between Sao₂ and Spo₂ improved when correcting for the underestimation of Spo₂ at low values. There is a poor agreement between Spo₂ and the gold standard Sao₂ during extreme hypobaric hypoxemia.Ottestad W, Kåsin JI, Høiseth LØ. Arterial oxygen saturation, pulse oximetery, and cerebral and tissue oximetry in hypobaric hypoxia. Aerospace Med Hum Perform. 2018; 89(12):1045-1049.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30487024     DOI: 10.3357/AMHP.5173.2018

Source DB:  PubMed          Journal:  Aerosp Med Hum Perform        ISSN: 2375-6314            Impact factor:   1.053


  5 in total

1.  Individual Differences in Hemodynamic Responses Measured on the Head Due to a Long-Term Stimulation Involving Colored Light Exposure and a Cognitive Task: A SPA-fNIRS Study.

Authors:  Hamoon Zohdi; Felix Scholkmann; Ursula Wolf
Journal:  Brain Sci       Date:  2021-01-05

2.  Pre-hospital critical care management of severe hypoxemia in victims of Covid-19: a case series.

Authors:  Jens Otto Mæhlen; Roger Mikalsen; Hans Julius Heimdal; Marius Rehn; Jostein S Hagemo; William Ottestad
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2021-01-12       Impact factor: 2.953

Review 3.  The Use of Pulse Oximetry in the Assessment of Acclimatization to High Altitude.

Authors:  Tobias Dünnwald; Roland Kienast; David Niederseer; Martin Burtscher
Journal:  Sensors (Basel)       Date:  2021-02-10       Impact factor: 3.576

Review 4.  Hypoxic Hypoxia and Brain Function in Military Aviation: Basic Physiology and Applied Perspectives.

Authors:  David M Shaw; Gus Cabre; Nicholas Gant
Journal:  Front Physiol       Date:  2021-05-17       Impact factor: 4.566

5.  Why COVID-19 Silent Hypoxemia Is Baffling to Physicians.

Authors:  Martin J Tobin; Franco Laghi; Amal Jubran
Journal:  Am J Respir Crit Care Med       Date:  2020-08-01       Impact factor: 21.405

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.