| Literature DB >> 30483662 |
Xiang Sheng1,2, Yali Wang1,3, Jiashuo Zhang1,2, Liqin Chen3, Yuan Lin1, Zhenmin Zhao1, Chengtao Li1, Suhua Zhang1.
Abstract
A forensic validation study of the Early Access Huaxia™ Platinum Polymerase Chain Reaction (PCR) kit was completed to document the performance capabilities and limitations. The genotyping of DNA samples was consistent across a large range of template DNA concentrations, with complete profiles obtained at 0.125 ng; however, no more than 2 mm × 1.2 mm punches of samples would be recommended for direct amplification. The size precision and accuracy test revealed the genotyping ability; while consistent results were obtained when comparing the kit with other commercially available systems. In addition, the whole PCR amplification can finish within approximately 45 min, making the system suitable for fast-detection. However, only partial profiles may be obtained with challenging samples, including DNA stored on Foam-Tipped Applicators (FTA) cards or some case samples. For the forensic application in ethnic groups, a total of 282 and 229 alleles were obtained in Han and Mongolia, respectively. Since the 23 short tandem repeats were independent from each other, the cumulative power of exclusion in duos was 0.999 999 157 188 and the cumulative power of exclusion in trios was 0.999 999 999 859 in the Han group while the cumulative power of exclusion in duos (CPEduo) was 0.999 998 848 26 and cumulative power of exclusion in trios (CPEtrio) was 0.999 999 999 79 in the Mongolia group. And good internal consistency was found between the two investigated groups and the Sichuan Han, Hui, Tibetan and Uygur according to available reference data.Entities:
Keywords: Early Access Huaxia™ Platinum PCR kit; Forensic genetics; short tandem repeats (STRs)
Year: 2018 PMID: 30483662 PMCID: PMC6197138 DOI: 10.1080/20961790.2018.1428782
Source DB: PubMed Journal: Forensic Sci Res ISSN: 2471-1411
Figure 1.Information of called alleles and PHR of control DNA 007 ranging from 2 to 0.0625 ng.
Stutter ratios for the Early Access HuaxiaTM Platinum PCR kit from 100 individuals.
| Minus stutter (%) | Plus stutter (%) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STR | Count | Max | Min | Mean | SD | Mean + 3SD | Count | Max | Min | Mean | SD | Mean + 3SD |
| 108 | 11.96 | 5.02 | 7.94 | 1.40 | 12.14 | 56 | 16.97 | 0.56 | 3.23 | 4.06 | 15.42 | |
| 137 | 11.98 | 2.62 | 7.09 | 2.30 | 13.99 | 66 | 18.67 | 0.53 | 3.62 | 3.86 | 15.19 | |
| 130 | 10.52 | 3.46 | 6.23 | 1.65 | 11.16 | 92 | 12.17 | 0.51 | 2.71 | 2.84 | 11.22 | |
| 92 | 12.29 | 3.57 | 6.59 | 1.59 | 11.35 | 80 | 13.59 | 0.64 | 2.78 | 3.07 | 11.98 | |
| 112 | 4.94 | 1.63 | 2.91 | 1.01 | 5.94 | 11 | 3.66 | 0.38 | 2.02 | 1.47 | 6.42 | |
| 140 | 11.38 | 0.42 | 7.64 | 1.54 | 11.64 | 65 | 12.33 | 0.81 | 4.27 | 3.52 | 14.84 | |
| 122 | 14.70 | 1.01 | 8.64 | 2.01 | 14.66 | 90 | 13.07 | 0.43 | 2.52 | 2.94 | 11.34 | |
| 146 | 18.27 | 4.73 | 7.72 | 2.44 | 15.03 | 84 | 13.47 | 0.54 | 2.76 | 3.15 | 12.22 | |
| 147 | 15.99 | 0.83 | 4.21 | 1.82 | 9.66 | 43 | 8.53 | 0.46 | 2.53 | 2.14 | 8.95 | |
| 130 | 8.22 | 0.79 | 5.55 | 1.44 | 9.86 | 77 | 18.13 | 0.54 | 3.09 | 3.27 | 12.89 | |
| 134 | 12.23 | 3.05 | 7.05 | 1.53 | 11.64 | 28 | 10.34 | 0.54 | 4.03 | 3.90 | 15.73 | |
| 121 | 5.56 | 0.47 | 2.85 | 0.74 | 5.08 | 39 | 7.89 | 0.22 | 2.95 | 1.50 | 7.46 | |
| 138 | 12.90 | 4.03 | 7.92 | 1.67 | 12.93 | 66 | 11.65 | 0.58 | 3.09 | 3.57 | 13.81 | |
| 128 | 21.50 | 0.76 | 7.90 | 3.99 | 9.88 | 107 | 20.95 | 0.84 | 4.80 | 3.45 | 15.14 | |
| 122 | 9.80 | 2.48 | 6.19 | 1.50 | 10.67 | 91 | 11.80 | 0.80 | 3.20 | 3.00 | 12.20 | |
| 130 | 9.78 | 1.97 | 4.78 | 2.01 | 10.81 | 75 | 8.17 | 0.41 | 1.83 | 1.87 | 7.45 | |
| 123 | 10.17 | 2.42 | 4.98 | 1.57 | 9.70 | 58 | 8.77 | 0.49 | 2.70 | 2.83 | 11.20 | |
| 165 | 10.66 | 0.65 | 7.19 | 1.58 | 11.93 | 118 | 10.93 | 0.73 | 2.35 | 2.60 | 10.14 | |
| 130 | 19.32 | 9.29 | 8.46 | 2.36 | 15.54 | 60 | 19.08 | 0.49 | 5.30 | 4.72 | 19.46 | |
| 117 | 14.47 | 1.88 | 8.59 | 2.02 | 14.64 | 90 | 13.68 | 0.74 | 3.08 | 3.47 | 13.49 | |
| 120 | 13.55 | 3.99 | 8.82 | 1.86 | 14.41 | 57 | 16.11 | 0.44 | 4.20 | 4.49 | 17.68 | |
| 137 | 17.33 | 3.37 | 8.80 | 2.06 | 14.99 | 35 | 16.49 | 0.34 | 4.32 | 4.56 | 18.00 | |
| 110 | 4.99 | 0.64 | 1.82 | 0.76 | 4.09 | 22 | 3.30 | 0.40 | 1.70 | 0.83 | 4.20 | |
Detected information of case samples from three injured persons of a car accident.
| Type | Samples | Calling rate (%) | Average peak height (RUF) | Average PHR | Note |
|---|---|---|---|---|---|
| Biological samples collected from individuals | Hair | 100 | 2 584 | 0.81 | 0.5 ng of extracted DNA for PCR |
| Buccal swab | 100 | 3 126 | 0.79 | 0.5 ng of extracted DNA for PCR | |
| Finger swab | 100 | 1 983 | 0.78 | 0.5 ng of extracted DNA for PCR | |
| Peripheral blood | 100 | 2 309 | 0.83 | 0.5 ng of extracted DNA for PCR | |
| Blood samples collected from the accident scene | Bloodstain on white shirt | 100 | 2 403 | 0.77 | Direct amplification; 1.2 mm2 |
| Bloodstain on dark blue jeans | 75.36 | 1 398 | 0.57 | Direct amplification; 1.2 mm2 | |
| Blood on airbag | 84.06 | 1 602 | 0.76 | Direct amplification; 1.2 mm2 | |
| Blood on leather seats | 95.65 | 2 011 | 0.73 | Collected on cotton swab; direct amplification; 1.2 mm2 | |
| Blood on steering wheel | 100 | 1 753 | 0.88 | Collected on cotton swab; direct amplification; 1.2 mm2 | |
| Blood samples collected on different materials | Blood on filter paper | 100 | 2 531 | 0.91 | Manual prepared with peripheral blood; direct amplification; 1.2 mm2 |
| Blood on FTA card | 86.96 | 1 652 | 0.62 | Manual prepared with peripheral blood; direct amplification; 1.2 mm2 | |
| Blood on cotton swab | 100 | 2 397 | 0.87 | Manual prepared with peripheral blood; direct amplification; 1.2 mm2 |
Figure 2.The mixed male/female DNA samples with known ratios amplified with the Early Access Huaxia™ Platinum PCR kit using the recommended protocol. Averaged percentages of detected minor alleles were against ratios of the mixture. Error bars represent the plus and minus standard deviations in triplicate.