Literature DB >> 30483458

Tear production and intraocular pressure values in clinically normal eyes of whooper swans (Cygnus cygnus).

Liga Kovalcuka1, Dmitrij Boiko2, David L Williams3.   

Abstract

The objective of this study was to determine the normal range of tear production and values of intraocular pressure (IOP) in clinically normal eyes of whooper swans (Cygnus cygnus). A total of 86 birds: 81 cygnets (6-10 weeks old) and 5 moulting - adult swans (3-6 years old) were examined in this study. Both eyes of all birds underwent a complete ophthalmic examination, including evaluation of tear production with the phenol red thread test (PRTT) and the assessment of the IOP by rebound tonometry, employing the TonoVet® device. The mean ± standard deviation of PRTT values were as follows: all cygnets (81) 22.59±3.48 mm/15s, male cygnets (45) 22.64±3.54 mm/15s, female cygnets (36) 22.53±3.44 mm/15s. IOP was as follows: all cygnets 11.30±3.55 mmHg, male cygnets 10.93±3.56 mmHg, female cygnets 11.74±3.50 mmHg. No statistically significant differences between right and left eye and between female and male cygnets were found for IOP and PRTT values. This study provides the reference values for the PRTT and IOP in healthy whooper swan cygnets, showing that PRTT determination of the tear production and rebound tonometry to evaluate the IOP methods are practical methods for ophthalmic examination in swans.

Entities:  

Keywords:  Eye; Intraocular pressure; Phenol red thread test; Tear production; Whooper swan

Year:  2018        PMID: 30483458      PMCID: PMC6172406          DOI: 10.4314/ovj.v8i3.14

Source DB:  PubMed          Journal:  Open Vet J        ISSN: 2218-6050


  19 in total

1.  Schirmer tear test results in normal horses and ponies: effect of age, season, environment, sex, time of day and placement of strips.

Authors:  J Beech; R A Zappala; G Smith; S Lindborg
Journal:  Vet Ophthalmol       Date:  2003-09       Impact factor: 1.644

2.  Accuracy and reproducibility of the TonoVet rebound tonometer in birds of prey.

Authors:  Anne Reuter; Kerstin Müller; Gisela Arndt; Johanna Corinna Eule
Journal:  Vet Ophthalmol       Date:  2010-09       Impact factor: 1.644

3.  Comparison of the rebound tonometer (TonoVet) with the applanation tonometer (TonoPen XL) in normal Eurasian Eagle owls (Bubo bubo).

Authors:  Man-Bok Jeong; Young-Jun Kim; Na-Young Yi; Shin-Ae Park; Won-Tae Kim; Se-Eun Kim; Je-Min Chae; Jong-Taek Kim; Hang Lee; Kang-Moon Seo
Journal:  Vet Ophthalmol       Date:  2007 Nov-Dec       Impact factor: 1.644

4.  Use of phenol red thread tests to evaluate tear production in clinically normal Amazon parrots and comparison with Schirmer tear test findings.

Authors:  Eric S Storey; Deborah A Carboni; Michael T Kearney; Thomas N Tully
Journal:  J Am Vet Med Assoc       Date:  2009-11-15       Impact factor: 1.936

5.  Reference intervals for intraocular pressure measured by rebound tonometry in ten raptor species and factors affecting the intraocular pressure.

Authors:  Anne Reuter; Kerstin Müller; Gisela Arndt; Johanna Corinna Eule
Journal:  J Avian Med Surg       Date:  2011-09       Impact factor: 0.557

6.  Reference values for selected ophthalmic diagnostic tests and clinical characteristics of chinchilla eyes (Chinchilla lanigera).

Authors:  Kerstin Müller; Daniela Alice Mauler; Johanna Corinna Eule
Journal:  Vet Ophthalmol       Date:  2010-09       Impact factor: 1.644

7.  The capybara eye: clinical tests, anatomic and biometric features.

Authors:  Fabiano Montiani-Ferreira; Jesse Truppel; Mariana H Tramontin; Ricardo G D'Octaviano Vilani; Rogério R Lange
Journal:  Vet Ophthalmol       Date:  2008 Nov-Dec       Impact factor: 1.644

8.  Ocular findings and reference values for selected ophthalmic diagnostic tests in the macaroni penguin (Eudyptes chrysolophus) and southern rockhopper penguin (Eudyptes chrysocome).

Authors:  Cassandra D Bliss; Susette Aquino; Sarah Woodhouse
Journal:  Vet Ophthalmol       Date:  2013-11-18       Impact factor: 1.644

9.  Tonometry of normal eyes in raptors.

Authors:  J Stiles; N C Buyukmihci; T B Farver
Journal:  Am J Vet Res       Date:  1994-04       Impact factor: 1.156

10.  Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: quantitative evaluation of variance due to position inaccuracies.

Authors:  A Prashar; J A Guggenheim; J T Erichsen; P M Hocking; J E Morgan
Journal:  Exp Eye Res       Date:  2007-07-20       Impact factor: 3.467

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.