Literature DB >> 17719031

Measurement of intraocular pressure (IOP) in chickens using a rebound tonometer: quantitative evaluation of variance due to position inaccuracies.

A Prashar1, J A Guggenheim, J T Erichsen, P M Hocking, J E Morgan.   

Abstract

Intraocular pressure (IOP), an important risk factor for glaucoma, is a continuous trait determined by a complex set of genetic and environmental factors that are largely unknown. Genetic studies in laboratory animals may facilitate the identification of genes that affect IOP. We examined the use of the rebound tonometer for measuring IOP in non-anaesthetised birds, along with the device's robustness to alignment errors. Calibration curves were obtained by measuring the IOP of cannulated chicken eyes with the rebound tonometer over a range of pressures. To simulate different types of alignment errors that might be expected with measurement of IOP in alert chickens, for some calibrations the tonometer was positioned (1) at various distances from the cornea, (2) laterally displaced from the visual axis, or (3) angled away from the visual axis. In vivo measurements were taken on three-week-old alert chickens from a layer line, a broiler line, and a layer-broiler "advanced intercross line" (AIL) designed to facilitate QTL mapping. The rebound tonometer showed excellent linearity (R2=0.95-0.99) during calibration, as well as robustness to variation in the probe-to-cornea distance over the range 3-5mm and to lateral displacement over the range 0-2mm. However, the tonometer appeared less robust to off-axis misalignment over the range 0-20 degrees (P<0.05). Also, the slope of calibration curves sometimes differed between eyes (P<0.001), presumably reflecting differences in ocular structure. The IOP measured in non-anaesthetised three-week-old AIL chickens was 17.51+/-0.13 mmHg (mean+/-S.E.; N=105 birds). IOP was significantly associated with corneal thickness (P<0.05) and body weight (P<0.001) in a regression model. Replicate measurements were necessary in order to gauge IOP accurately in individual birds; a series of seven tonometry sessions over a 12-h period during the light phase of the light/dark cycle permitted IOP to be measured with a 95% CI of +/-0.7 mmHg. IOP did not differ significantly between the broiler and layer chicken lines which served as the progenitor lines for the AIL. In conclusion, the rebound tonometer permits rapid estimation of IOP in chickens and is well tolerated. The small alignment errors that are expected when taking measurements in non-anaesthetised animals are unlikely to affect accuracy. Since high IOP is a major risk factor for glaucoma, identifying QTL controlling IOP may offer future health benefits. However, our preliminary findings highlight several obstacles to mapping such QTL using the chicken advanced intercross line evaluated here.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17719031     DOI: 10.1016/j.exer.2007.07.010

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  9 in total

1.  The influence of lamellar orientation on corneal material behavior: biomechanical and structural changes in an avian corneal disorder.

Authors:  Craig Boote; Ahmed Elsheikh; Wael Kassem; Christina S Kamma-Lorger; Paul M Hocking; Nick White; Chris F Inglehearn; Manir Ali; Keith M Meek
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-10       Impact factor: 4.799

2.  Tear production and intraocular pressure values in clinically normal eyes of whooper swans (Cygnus cygnus).

Authors:  Liga Kovalcuka; Dmitrij Boiko; David L Williams
Journal:  Open Vet J       Date:  2018-09-28

3.  A Comparison of Applanation and Rebound Tonometers in Young Chicks.

Authors:  Lisa A Ostrin; Christine F Wildsoet
Journal:  Curr Eye Res       Date:  2020-07-03       Impact factor: 2.424

4.  Integrative transcriptomic and proteomic analysis reveals CD9/ITGA4/PI3K-Akt axis mediates trabecular meshwork cell apoptosis in human glaucoma.

Authors:  Junwei Yan; Xuejiao Yang; Xuefei Jiao; Xian Yang; Mingjin Guo; Yunqing Chen; Lu Zhan; Wenshi Chen
Journal:  J Cell Mol Med       Date:  2019-11-03       Impact factor: 5.310

5.  Comparative intraocular pressure measurements using three different rebound tonometers through in an ex vivo analysis and clinical trials in canine eyes.

Authors:  Jaeho Shim; Seonmi Kang; Yoonji Park; Sunhyo Kim; Seokmin Go; Eunji Lee; Kangmoon Seo
Journal:  Vet Ophthalmol       Date:  2020-06-05       Impact factor: 1.644

6.  Zebrafish: An In Vivo Screening Model to Study Ocular Phenotypes.

Authors:  Wim H Quint; Kirke C D Tadema; Johan H C Crins; Nina C C J Kokke; Magda A Meester-Smoor; Rob Willemsen; Caroline C W Klaver; Adriana I Iglesias
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

7.  Light Color and the Commercial Broiler: Effect on Ocular Health and Visual Acuity.

Authors:  Bruna Remonato Franco; Marina L Leis; Melody Wong; Tory Shynkaruk; Trever Crowe; Bryan Fancher; Nick French; Scot Gillingham; Karen Schwean-Lardner
Journal:  Front Physiol       Date:  2022-03-10       Impact factor: 4.566

8.  Intraocular pressure measurements using the TONOVET® rebound tonometer: Influence of the probe-cornea distance.

Authors:  Blanche D Rodrigues; Fabiano Montiani-Ferreira; Mariza Bortolini; André T Somma; András M Komáromy; Peterson Triches Dornbusch
Journal:  Vet Ophthalmol       Date:  2020-10-17       Impact factor: 1.644

9.  The influence of the tonometer position on canine intraocular pressure measurements using the Tonovet® rebound tonometer.

Authors:  Juliana Kravetz de Oliveira; Fabiano Montiani-Ferreira; David L Williams
Journal:  Open Vet J       Date:  2018-03-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.