Literature DB >> 30478516

Competitive light-initiated chemiluminescent assay: using 5-α-dihydrotestosterone-BSA as competitive antigen for quantitation of total testosterone in human sera.

Yaqiong Cui1, Tiantian She2, Hong Zhao2, Jiuzhi Li3, Liuxu Li2, Weizhen Gao1, Huiqiang Li4.   

Abstract

This paper described a homogeneous method, light-initiated chemiluminescent assay (LICA), for quantitation of total testosterone in human sera. The assay was bead based and built on a competitive-binding reaction format, in which 5-α-dihydrotestosterone (5-α-DHT) competed with the testosterone in serum samples in binding with biotinylated anti-testosterone antibody. The more testosterone in the serum sample, the less 5-α-DHT that bonded with biotinylated anti-testosterone antibodies. 5-α-DHT was coupled with emission beads (doped with thioxene derivatives and Eu(III) as a chemiluminescence emitter) via bovine serum albumin as a linker. Once streptavidin-coated sensitizer beads (modified with phthalocyanine as a photosensitizer) were added, the streptavidin/biotin reaction between 5-α-DHT-bound anti-testosterone antibody and sensitizer beads could bring emission and sensitizer beads together, which allowed energy transfer from sensitizer bead to emission bead. As such, an exciting light (680 nm) impinging on the sensitizer beads led to light emission at 520-620 nm by emission beads. The strength of the emitted light was inversely proportional to the testosterone in serum sample. The detection range of this assay was from 13.3 to 1200 ng/dL. The coefficient variation for intra- and inter-assay was lower than 15%. The recovery of this method ranged from 95.5 to 105.9% for different samples. Moreover, the LICA assay was highly specific with low cross-reactivity and interference. The concentration of testosterone from 58 serum samples analyzed by the LICA method significantly correlated (y = 0.97x + 1.87, R2 = 0.970, p < 0.001) with those obtained with the SIEMENS Centaur Xp System. Graphical abstract ᅟ.

Entities:  

Keywords:  5-α-Dihydrotestosterone; Competitive immunoassay; Light-initiated chemiluminescent assay (LICA); Quantitative assay; Testosterone

Mesh:

Substances:

Year:  2018        PMID: 30478516     DOI: 10.1007/s00216-018-1496-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Quantitative determination of human serum testosterone via isotope dilution ultra‑performance liquid chromatography tandem mass spectrometry.

Authors:  Guang Sun; Jinmei Xue; Liuxu Li; Xue Li; Yaqiong Cui; Bin Qiao; Dianjun Wei; Huiqiang Li
Journal:  Mol Med Rep       Date:  2020-06-15       Impact factor: 2.952

2.   Comparison and evaluation of Abbott chemiluminescent microparticle immunoassay and ChIVD light-initiated chemiluminescent assay in the detection of Treponema pallidum antibody.

Authors:  Xiaohui Chen; Ruifeng Yang; Yongming Liang; Teng Yuan; Jiansuo Zhou; Tiancheng Wang; Liyan Cui
Journal:  J Clin Lab Anal       Date:  2020-03-04       Impact factor: 2.352

3.  Quantitation of estradiol by competitive light-initiated chemiluminescent assay using estriol as competitive antigen.

Authors:  Jiuzhi Li; Liuxu Li; Ying Bian; Yang Yu; Zhonghua Qiang; Yuexiang Zhang; Huiqiang Li
Journal:  J Clin Lab Anal       Date:  2019-08-24       Impact factor: 2.352

4.  Performance characteristics of the light-initiated chemiluminescent assay for quantitative determination of progesterone.

Authors:  Kai Chen; Dan Wu; Mengdan Gao; Yongfeng Yan; Huiqiang Li
Journal:  Ann Transl Med       Date:  2021-09

5.  Light-initiated chemiluminescent assay of 17β-estradiol metrological traceability system established by manufacturer according to ISO17511:2020 and basic performance evaluation performed by clinical end-users.

Authors:  Chenyu Shang; Xue Yuan; Haibiao Lin; Dongdong Liu; Xiaoxin Yan; Xinxin Ren; Xiyang Lin; Huang Di; Huiqiang Li
Journal:  J Clin Lab Anal       Date:  2022-04-26       Impact factor: 3.124

6.  A hook-effect-free homogeneous light-initiated chemiluminescence assay: is it reliable for screening and the quantification of the hepatitis B surface antigen?

Authors:  Ruifeng Yang; Liyan Cui; Yan Liu; Xu Cong; Ran Fei; Shuping Wu; Lai Wei
Journal:  Ann Transl Med       Date:  2020-05
  6 in total