Literature DB >> 30471565

An integrated microfluidic device with solid-phase extraction and graphene oxide quantum dot array for highly sensitive and multiplex detection of trace metal ions.

Minsu Park1, Tae Seok Seo2.   

Abstract

An integrated microfluidic device, consisting of a solid-phase extraction (SPE) unit for metal ion pretreatment, a micropump, a micromixer, and a detachable graphene oxide quantum dot (GOQD) array chip was constructed for selective and sensitive detection of As3+, Cd2+, and Pb2+. The entire process could be sequentially and automatically completed by actuating a pneumatic micropump. Effect of the pH for metal ion capture and pumping scheme for recovery efficiency were investigated on a chip. The ion As3+, Cd2+, and Pb2+ whose concentrations ranged from 10-2 µM to 102 µM were successfully recovered with high efficiency over 80%. Monoplex and multiplex detection of As3+, Cd2+, and Pb2+ were then executed on a GOQD array chip. The target metal ions were specifically captured on the DNA aptamer linked GOQD array, which results in the fluorescence quenching of GOQD due to the electron transfer from the GOQD to metal ions under the laser irradiation. The proposed integrated SPE-GOQD array based microdevice could perform As3+, Cd2+, and Pb2+ detection with detection limits of 5.03 nM, 41.1 nM, and 4.44 nM, respectively. Simultaneous multiplex detection for binary or ternary mixture of As3+, Cd2+, and Pb2+ was performed, and the proposed integrated microdevice also showed high recovery values ranging from 83.52% to 128.3% from the environmental samples.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DNA aptamer; Graphene oxide quantum dot; Metal ion sensor; Microdevice; Solid-phase extraction

Mesh:

Substances:

Year:  2018        PMID: 30471565     DOI: 10.1016/j.bios.2018.11.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  3D Printed Microfluidic Devices for Solid-Phase Extraction and On-Chip Fluorescent Labeling of Preterm Birth Risk Biomarkers.

Authors:  Anna V Bickham; Chao Pang; Benjamin Q George; David J Topham; Jacob B Nielsen; Gregory P Nordin; Adam T Woolley
Journal:  Anal Chem       Date:  2020-09-03       Impact factor: 6.986

Review 2.  Affinity biosensors developed with quantum dots in microfluidic systems.

Authors:  Sultan Şahin; Caner Ünlü; Levent Trabzon
Journal:  Emergent Mater       Date:  2021-03-10

3.  Interconnectable solid-liquid protein extraction unit and chip-based dilution for multiplexed consumer immunodiagnostics.

Authors:  Georgina M S Ross; Daniel Filippini; Michel W F Nielen; Gert Ij Salentijn
Journal:  Anal Chim Acta       Date:  2020-10-16       Impact factor: 6.558

Review 4.  Recent advances in cellulose-based membranes for their sensing applications.

Authors:  Jiang Fan; Sufeng Zhang; Fei Li; Yonglin Yang; Min Du
Journal:  Cellulose (Lond)       Date:  2020-09-11       Impact factor: 5.044

5.  Graphene oxide and its derivatives as promising In-vitro bio-imaging platforms.

Authors:  Yasaman Esmaeili; Elham Bidram; Ali Zarrabi; Abbas Amini; Chun Cheng
Journal:  Sci Rep       Date:  2020-10-22       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.