Literature DB >> 30469711

Near-infrared acetylene sensor system using off-axis integrated-cavity output spectroscopy and two measurement schemes.

Kaiyuan Zheng, Chuantao Zheng, Qixin He, Dan Yao, Lien Hu, Yu Zhang, Yiding Wang, Frank K Tittel.   

Abstract

For highly sensitive and accurate acetylene (C2H2) detection, a near-infrared (NIR) off-axis integrated-cavity output spectroscopy (OA-ICOS) sensor system based on an ultra-compact cage-based absorption cell was proposed. The absorption cell with dimensions of 10 cm × 8 cm × 6 cm realized a dense-pattern and an easily-aligned stable optical system. The OA-ICOS sensor system employed a 6cm-long optical cavity that was formed by two mirrors with a reflectivity of 99.35% and provided an effective absorption path length of ∼9.28 m. The performance of the C2H2 sensor system based on two measurement schemes, i.e. laser direct absorption spectroscopy (LDAS) and wavelength modulation spectroscopy (WMS) is reported. A NIR distributed feedback (DFB) laser was employed for targeting a C2H2 absorption line at 6523.88 cm-1. An Allan deviation analysis yielded a detection sensitivity of 760 parts-per-billion in volume (ppbv) for an averaging time of 304 s using the LDAS-based OA-ICOS. A detection sensitivity of 85 ppbv for an averaging time of 250 s was obtained using the WMS-based OA-ICOS, which was further improved by a factor of ~9 compared to the result obtained with the LDAS method. The proposed sensor system has the advantages of reduced size and cost with acceptable detection sensitivity, which is suitable for applications in trace gas sensing in harsh environments and weight-limited balloon-embedded observations.

Entities:  

Year:  2018        PMID: 30469711     DOI: 10.1364/OE.26.026205

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  Long-Term Stable Online Acetylene Detection by a CEAS System with Suppression of Cavity Length Drift.

Authors:  Qixin He; Qibo Feng; Jiakun Li
Journal:  Sensors (Basel)       Date:  2019-01-26       Impact factor: 3.576

2.  Highly sensitive broadband differential infrared photoacoustic spectroscopy with wavelet denoising algorithm for trace gas detection.

Authors:  Lixian Liu; Huiting Huan; Wei Li; Andreas Mandelis; Yafei Wang; Le Zhang; Xueshi Zhang; Xukun Yin; Yuxiang Wu; Xiaopeng Shao
Journal:  Photoacoustics       Date:  2020-12-05

3.  On-chip mid-infrared silicon-on-insulator waveguide methane sensor using two measurement schemes at 3.291 μm.

Authors:  Huan Zhao; Chuantao Zheng; Mingquan Pi; Lei Liang; Fang Song; Yu Zhang; Yiding Wang; Frank K Tittel
Journal:  Front Chem       Date:  2022-08-23       Impact factor: 5.545

Review 4.  Review of Incoherent Broadband Cavity-Enhanced Absorption Spectroscopy (IBBCEAS) for Gas Sensing.

Authors:  Kaiyuan Zheng; Chuantao Zheng; Yu Zhang; Yiding Wang; Frank K Tittel
Journal:  Sensors (Basel)       Date:  2018-10-27       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.