Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage.

Matteo Bianchi1, Gil Marom1,2, Ram P Ghosh1, Oren M Rotman1, Puja Parikh3, Luis Gruberg4, Danny Bluestein5.   

Abstract

Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical valve replacement in high-risk patients afflicted by severe aortic stenosis. Despite newer-generation devices enhancements, post-procedural complications such as paravalvular leakage (PVL) and related thromboembolic events have been hindering TAVR expansion into lower-risk patients. Computational methods can be used to build and simulate patient-specific deployment of transcatheter aortic valves (TAVs) and help predict the occurrence and degree of PVL. In this study finite element analysis and computational fluid dynamics were used to investigate the influence of procedural parameters on post-deployment hemodynamics on three retrospective clinical cases affected by PVL. Specifically, TAV implantation depth and balloon inflation volume effects on stent anchorage, degree of paravalvular regurgitation and thrombogenic potential were analyzed for cases in which Edwards SAPIEN and Medtronic CoreValve were employed. CFD results were in good agreement with corresponding echocardiography data measured in patients in terms of the PVL jets locations and overall PVL degree. Furthermore, parametric analyses demonstrated that positioning and balloon over-expansion may have a direct impact on the post-deployment TAVR performance, achieving as high as 47% in PVL volume reduction. While the model predicted very well clinical data, further validation on a larger cohort of patients is needed to verify the level of the model's predictions in various patient-specific conditions. This study demonstrated that rigorous and realistic patient-specific numerical models could potentially serve as a valuable tool to assist physicians in pre-operative TAVR planning and TAV selection to ultimately reduce the risk of clinical complications.

Entities:  

Keywords:  CFD; Computational fluid dynamics; FEA; Finite element analysis; TAVI; TAVR

Mesh:

Year:  2018        PMID: 30460623      PMCID: PMC6476328          DOI: 10.1007/s10237-018-1094-8

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  19 in total

1.  A Distributed Lumped Parameter Model of Blood Flow.

Authors:  Mehran Mirramezani; Shawn C Shadden
Journal:  Ann Biomed Eng       Date:  2020-07-01       Impact factor: 3.934

2.  The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation.

Authors:  Giorgia Rocatello; Nahid El Faquir; Ole de Backer; Martin J Swaans; Azeem Latib; Luca Vicentini; Patrick Segers; Matthieu De Beule; Peter de Jaegere; Peter Mortier
Journal:  J Cardiovasc Transl Res       Date:  2019-08-23       Impact factor: 4.132

3.  Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve.

Authors:  Salvatore Pasta; Stefano Cannata; Giovanni Gentile; Marzio Di Giuseppe; Federica Cosentino; Francesca Pasta; Valentina Agnese; Diego Bellavia; Giuseppe M Raffa; Michele Pilato; Caterina Gandolfo
Journal:  Med Biol Eng Comput       Date:  2020-02-06       Impact factor: 2.602

4.  Validating In Silico and In Vitro Patient-Specific Structural and Flow Models with Transcatheter Bicuspid Aortic Valve Replacement Procedure.

Authors:  Salwa B Anam; Brandon J Kovarovic; Ram P Ghosh; Matteo Bianchi; Ashraf Hamdan; Rami Haj-Ali; Danny Bluestein
Journal:  Cardiovasc Eng Technol       Date:  2022-04-07       Impact factor: 2.495

5.  Structural Heart Valve Disease in the Era of Change and Innovation: The Crosstalk between Medical Sciences and Engineering.

Authors:  Francesco Nappi; Antonio Nenna; Massimo Chello
Journal:  Bioengineering (Basel)       Date:  2022-05-24

6.  A computational framework for post-TAVR cardiac conduction abnormality (CCA) risk assessment in patient-specific anatomy.

Authors:  Symon Reza; Matteo Bianchi; Brandon Kovarovic; Salwa Anam; Marvin J Slepian; Ashraf Hamdan; Rami Haj-Ali; Danny Bluestein
Journal:  Artif Organs       Date:  2022-02-07       Impact factor: 2.663

7.  Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage.

Authors:  Karin Lavon; Gil Marom; Matteo Bianchi; Rotem Halevi; Ashraf Hamdan; Adi Morany; Ehud Raanani; Danny Bluestein; Rami Haj-Ali
Journal:  Med Biol Eng Comput       Date:  2019-08-01       Impact factor: 2.602

8.  Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis.

Authors:  Ram P Ghosh; Gil Marom; Matteo Bianchi; Karl D'souza; Wojtek Zietak; Danny Bluestein
Journal:  Biomech Model Mechanobiol       Date:  2020-02-24

9.  Patient-specific in vitro testing for evaluating TAVR clinical performance-A complementary approach to current ISO standard testing.

Authors:  Brandon J Kovarovic; Oren M Rotman; Puja Parikh; Marvin J Slepian; Danny Bluestein
Journal:  Artif Organs       Date:  2020-12-07       Impact factor: 3.094

10.  Paravalvular leak prediction after transcatheter aortic valve replacement with self-expandable prosthesis based on quantitative aortic calcification analysis.

Authors:  Agata Wiktorowicz; Adrian Wit; Krzysztof Piotr Malinowski; Artur Dziewierz; Lukasz Rzeszutko; Dariusz Dudek; Pawel Kleczynski
Journal:  Quant Imaging Med Surg       Date:  2021-02
View more