Displaced medial end clavicular fractures treated with an inverted distal clavicle plate contoured through 90 degrees.

Andrew Titchener1, Abbas See1, Lee Van Rensburg1, Graham Tytherleigh-Strong2.   

Abstract

BACKGROUND: This study assessed whether treating medial end clavicular fractures using an inverted distal clavicle locking plate, twisted through 90° around its axis, would allow for a less invasive surgical approach and improve screw trajectory insertion.
MATERIALS AND METHODS: We searched the databases of the 2 senior authors for patients who had sustained an acute, displaced fracture of the medial end of the clavicle and had undergone operative fixation using an inverted distal clavicle plate contoured through 90°. Through an inferior incision, a contoured locking plate was positioned on the anterior surface of the medial end of the clavicle. Up to 8 unicortical screws were inserted from anterior to posterior through the medial end of the plate. The lateral end was contoured and fixed to the superior clavicular surface. The patients were assessed preoperatively and at 1 month, 4 months, and final follow-up. Preoperative and postoperative plain x-ray images and computed tomography scans were reviewed.
RESULTS: The study included 8 patients (average age, 31.3 years; range, 15-59 years) with displaced fractures who underwent fixation. The median follow-up time was 30.5 months (range, 24-45 months). All patients reached clinical and radiographic union at 4 months. The mean 11-item version of the Disabilities of the Arm, Shoulder, and Hand score was 0.6 (range, 0-2.3). All of the patients had returned to their preinjury level of sport and activity. None of the patients had a complication.
CONCLUSION: Contouring an inverted distal clavicle plate through 90° may improve fixation options by allowing access to the anterior clavicle when treating medial clavicular fractures. Crown
Copyright © 2018. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Clavicular fracture; fracture union; intra-articular fracture; locking plate; sternoclavicular joint; unicortical screws

Mesh:

Year:  2018        PMID: 30454930     DOI: 10.1016/j.jse.2018.08.047

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  6 in total

1.  The incidence of medial end clavicle fractures is higher than had previously been considered.

Authors:  Nawfal Al-Hadithy; Zakir H Khokher; Niel Kang; Lee Van Rensburg; Graham Tytherleigh-Strong
Journal:  Shoulder Elbow       Date:  2020-05-07

2.  What Are the Functional Outcomes and Pain Scores after Medial Clavicle Fracture Treatment?

Authors:  Matthew H Lindsey; Phillip Grisdela; Laura Lu; Dafang Zhang; Brandon Earp
Journal:  Clin Orthop Relat Res       Date:  2021-11-01       Impact factor: 4.755

Review 3.  An evaluation of treatment options for medial, midshaft, and distal clavicle fractures: a systematic review and meta-analysis.

Authors:  Christopher Vannabouathong; Justin Chiu; Rahil Patel; Shreyas Sreeraman; Elias Mohamed; Mohit Bhandari; Kenneth Koval; Michael D McKee
Journal:  JSES Int       Date:  2020-05-04

4.  Medial clavicle pseudarthrosis successfully treated with an inverted distal clavicle locking plate.

Authors:  Yu Sasaki; Sang Yang Lee; Takashi Iwakura; Tomoaki Fukui; Keisuke Oe; Tomoyuki Matsumoto; Takehiko Matsushita; Teruya Kawamoto; Yutaka Mifune; Ryosuke Kuroda; Takahiro Niikura
Journal:  Ann Med Surg (Lond)       Date:  2019-06-06

5.  A Sternoclavicular Joint-Specific Plate for the Displaced Medial-End Clavicle Fracture.

Authors:  Yunli Zhu; Fucun Liu; Lie Lin; Chuanyi Zhang; Bin Wang; Shouli Wang
Journal:  Front Surg       Date:  2022-04-29

Review 6.  Balser Plate Stabilization for Traumatic Sternoclavicular Instabilities or Medial Clavicle Fractures: A Case Series and Literature Review.

Authors:  Wei-Lou Feng; Xiao Cai; Shu-Hao Li; Zi-Jun Li; Kun Zhang; Hao Wang; Jun Zhang; Yang-Jun Zhu; Dong-Xu Feng
Journal:  Orthop Surg       Date:  2020-09-06       Impact factor: 2.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.