Real-time oncological guidance using diffuse reflectance spectroscopy in electrosurgery: the effect of coagulation on tissue discrimination.

Maartje W Adank1, Julie C Fleischer1, Jenny Dankelman1, Benno H W Hendriks1,2.   

Abstract

In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. However, because tumor surgeries are often performed with an electrosurgical knife, the effect of a coagulated tissue layer on DRS measurements must be taken into account. It is evaluated whether real-time DRS measurements obtained with a photonic electrosurgical knife could provide useful information of tissue properties also when tissue is coagulated and cut. The size of the coagulated area is determined and the effect of its presence on DR spectra is studied using ex vivo porcine adipose and muscle tissue. A coagulated tissue layer with a depth of 0.1 to 0.4 mm is observed after coagulating muscle with an electrosurgical knife. The results show that the effect of coagulating adipose tissue is negligible. Using the fat/water ratio's calculated from the measured spectra of the photonic electrosurgical knife, it was possible to determine the distance from the instrument tip to a tissue transition during cutting. In conclusion, the photonic electrosurgical knife can determine tissue properties of coagulated and cut tissue and has, therefore, the potential to provide real-time feedback about the presence of breast tumor margins during cutting, helping surgeons to establish negative margins and improve patient outcome. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  coagulation; diffuse reflectance spectroscopy; electrosurgical knife; intraoperative guidance

Mesh:

Year:  2018        PMID: 30447060     DOI: 10.1117/1.JBO.23.11.115004

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  1 in total

1.  Tissue-mimicking phantom materials with tunable optical properties suitable for assessment of diffuse reflectance spectroscopy during electrosurgery.

Authors:  Sara Azizian Amiri; Pieter Van Berckel; Marco Lai; Jenny Dankelman; Benno H W Hendriks
Journal:  Biomed Opt Express       Date:  2022-04-04       Impact factor: 3.562

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.