Literature DB >> 30441321

Power Wheelchair Footplate Pressure and Positioning Sensor.

Steve J A Majerus, Joseph Lerchbacker, Daniel Barbaro, Steven J Mitchell, Kath M Bogie, M Kristi Henzel.   

Abstract

Power wheelchair users are at risk for severe injuries caused by foot mis-position on the footplate. This can lead to collisions or foot dragging which are severe or lifethreatening injuries for people with spinal cord injuries. The foot cannot be safely immobilized due to tilting pressure relief injuries, therefore, the foot can easily fall into a vulnerable position without the user realizing it. To reduce the likelihood of injury, we have developed a sensor for monitoring foot position in real time, as the wheelchair is driven. The sensor uses an array of force-sensing resistors and infrared distance sensors to detect the pressure and location of the foot within the immediate confines of the footplate. Sensor arrays with 23 force sensors and 14 infrared sensors per foot were fabricated on standard printed circuit boards and encapsulated in a durable thermoplastic urethane for environmental resistance. Fabricated sensors transmitted foot pressures and position data at 10 Hz using a Bluetooth Low Energy radio. An iOS app was developed to notify users of vulnerable foot position. Measured results confirmed the functionality of the system over typical foot pressures, and indicated that the device is ready for next-stage clinical trials with spinal cord injured power wheelchair users.

Entities:  

Mesh:

Year:  2018        PMID: 30441321      PMCID: PMC8091137          DOI: 10.1109/EMBC.2018.8513373

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  8 in total

1.  The application of force-sensing resistor sensors for measuring forces developed by the human hand.

Authors:  A Nikonovas; A J L Harrison; S Hoult; D Sammut
Journal:  Proc Inst Mech Eng H       Date:  2004       Impact factor: 1.617

2.  Determining level of postural control in young adults using force-sensing resistors.

Authors:  Alpha Agape Gopalai; S M N Arosha Senanayake; Darwin Gouwanda
Journal:  IEEE Trans Inf Technol Biomed       Date:  2011-04-07

3.  Static and cyclic performance evaluation of sensors for human interface pressure measurement.

Authors:  Jeffrey G Dabling; Anton Filatov; Jason W Wheeler
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

4.  Wheelchair safety--adverse reports to the United States Food and Drug Administration.

Authors:  R L Kirby; S A Ackroyd-Stolarz
Journal:  Am J Phys Med Rehabil       Date:  1995 Jul-Aug       Impact factor: 2.159

Review 5.  Falls, fractures, and osteoporosis after stroke: time to think about protection?

Authors:  Kenneth E S Poole; Jonathan Reeve; Elizabeth A Warburton
Journal:  Stroke       Date:  2002-05       Impact factor: 7.914

6.  Instrumented socket inserts for sensing interaction at the limb-socket interface.

Authors:  Eric C Swanson; Jake B McLean; Katheryn J Allyn; Christian B Redd; Joan E Sanders
Journal:  Med Eng Phys       Date:  2017-12-08       Impact factor: 2.242

7.  Wheelchair-related accidents: relationship with wheelchair-using behavior in active community wheelchair users.

Authors:  Wan-Yin Chen; Yuh Jang; Jung-Der Wang; Wen-Ni Huang; Chan-Chia Chang; Hui-Fen Mao; Yen-Ho Wang
Journal:  Arch Phys Med Rehabil       Date:  2011-06       Impact factor: 3.966

8.  Osteoporotic fractures and hospitalization risk in chronic spinal cord injury.

Authors:  L R Morse; R A Battaglino; K L Stolzmann; L D Hallett; A Waddimba; D Gagnon; A A Lazzari; E Garshick
Journal:  Osteoporos Int       Date:  2008-06-26       Impact factor: 4.507

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.