Literature DB >> 30430436

Effects of Individual Ion Energies on Charge Measurements in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS).

Andrew G Elliott1, Conner C Harper1, Haw-Wei Lin1, Evan R Williams2.   

Abstract

A method to correct for the effect of ion energy on charge measurements of individual ions trapped and weighed with charge detection mass spectrometry (CDMS) is demonstrated. Ions with different energies induce different signal patterns inside an electrostatic ion trap. The sum of the amplitudes of the fundamental and second harmonic frequencies in the Fourier transform of the induced signal, which has been used to obtain the ion charge, depends on both ion energy and charge. The amplitudes of the fundamental frequencies of ions increase over time as ions lose energy by collisions with background gas and solvent loss from larger ions. Model ion signals are simulated with the same time-domain amplitude at different energies and frequencies and the resulting fundamental frequency amplitudes are used to normalize real ion signals for energy and frequency effects. The fundamental frequency amplitude decreases dramatically below 20 kHz and increases by ~ 17% from the highest energy to lowest energy that is stable with a given trap potential at all frequencies. Normalizing the fundamental frequency amplitude with the modeled amplitudes removes the systematic changes in the charge measurement of polyethylene glycol (PEG) and other ions and makes it possible to signal average the amplitude over long times, which reduces the charge uncertainty to 0.04% for a PEG ion for a 500-ms measurement. This method improves charge measurement accuracy and uncertainty, which are important for high-accuracy mass measurement with CDMS. Graphical abstract ᅟ.

Entities:  

Keywords:  CDMS; Charge detection mass spectrometry; Fourier transform; Harmonics; Ion charge; Ion energy

Year:  2018        PMID: 30430436     DOI: 10.1007/s13361-018-2094-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  30 in total

1.  Mass Spectrometry of an Intact Virus The authors gratefully acknowledge Jennifer Boydston for her helpful comments and suggestions. G.S. is grateful for support from the NIH (GM55775). The work at LBL was supported by the Director, Office of Energy Research, Office of Health and Environmental Research, Human Genome Program, U.S. Department of Energy under contract number DE-AC03-76SF00098.

Authors:  Stephen D. Fuerstenau; W. Henry Benner; John J. Thomas; Christophe Brugidou; Brian Bothner; Gary Siuzdak
Journal:  Angew Chem Int Ed Engl       Date:  2001-02-02       Impact factor: 15.336

2.  Mass, mobility and MSn measurements of single ions using charge detection mass spectrometry.

Authors:  Andrew G Elliott; Conner C Harper; Haw-Wei Lin; Evan R Williams
Journal:  Analyst       Date:  2017-07-24       Impact factor: 4.616

3.  Charge-monitoring laser-induced acoustic desorption mass spectrometry for cell and microparticle mass distribution measurement.

Authors:  Wen-Ping Peng; Huan-Chang Lin; Hsin-Hung Lin; Minglee Chu; Alice L Yu; Huan-Cheng Chang; Chung-Hsuan Chen
Journal:  Angew Chem Int Ed Engl       Date:  2007       Impact factor: 15.336

4.  A multi-stage image charge detector made from printed circuit boards.

Authors:  Brandon L Barney; R Terik Daly; Daniel E Austin
Journal:  Rev Sci Instrum       Date:  2013-11       Impact factor: 1.523

5.  Boundaries of mass resolution in native mass spectrometry.

Authors:  Philip Lössl; Joost Snijder; Albert J R Heck
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-04       Impact factor: 3.109

6.  Single CdSe/ZnS nanocrystals in an ion trap: charge and mass determination and photophysics evolution with changing mass, charge, and temperature.

Authors:  David M Bell; Collin R Howder; Ryan C Johnson; Scott L Anderson
Journal:  ACS Nano       Date:  2014-01-14       Impact factor: 15.881

7.  Charging megadalton poly(ethylene oxide)s by electrospray ionization. A charge detection mass spectrometry study.

Authors:  Tristan Doussineau; Michel Kerleroux; Xavier Dagany; Christian Clavier; Marc Barbaire; Jacques Maurelli; Rodolphe Antoine; Philippe Dugourd
Journal:  Rapid Commun Mass Spectrom       Date:  2011-03-15       Impact factor: 2.419

8.  Studying 18 MDa virus assemblies with native mass spectrometry.

Authors:  Joost Snijder; Rebecca J Rose; David Veesler; John E Johnson; Albert J R Heck
Journal:  Angew Chem Int Ed Engl       Date:  2013-02-28       Impact factor: 15.336

9.  Determining Energies and Cross Sections of Individual Ions Using Higher-Order Harmonics in Fourier Transform Charge Detection Mass Spectrometry (FT-CDMS).

Authors:  Conner C Harper; Andrew G Elliott; Haw-Wei Lin; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2018-06-02       Impact factor: 3.109

10.  Analysis of a common cold virus and its subviral particles by gas-phase electrophoretic mobility molecular analysis and native mass spectrometry.

Authors:  Victor U Weiss; Jessica Z Bereszcazk; Marlene Havlik; Peter Kallinger; Irene Gösler; Mohit Kumar; Dieter Blaas; Martina Marchetti-Deschmann; Albert J R Heck; Wladyslaw W Szymanski; Günter Allmaier
Journal:  Anal Chem       Date:  2015-08-12       Impact factor: 6.986

View more
  2 in total

1.  Enhanced Multiplexing in Fourier Transform Charge Detection Mass Spectrometry by Decoupling Ion Frequency from Mass to Charge Ratio.

Authors:  Conner C Harper; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2019-11-12       Impact factor: 3.109

Review 2.  Native Mass Spectrometry of Membrane Proteins.

Authors:  James E Keener; Guozhi Zhang; Michael T Marty
Journal:  Anal Chem       Date:  2020-10-28       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.