| Literature DB >> 30425950 |
Gianluca Rigatelli1, Marco Zuin2, Fabio Dell'Avvocata1, Aravinda Nanjundappa3, Ramesh Daggubati4, Thach Nguyen5,6.
Abstract
OBJECTIVES: To non-invasively evaluate by computational fluid dynamic (CFD) analysis the physiology and rheology of aortoiliac bifurcation disease at different angles and different stent configurations.Entities:
Keywords: computational fluid dynamic; endovascular; iliac artery; stenting techniques
Year: 2018 PMID: 30425950 PMCID: PMC6231302 DOI: 10.2478/jtim-2018-0020
Source DB: PubMed Journal: J Transl Int Med ISSN: 2224-4018
Figure 1Schematic representation of the aortic Carrefour showing the considered angles and the fixed stenosis.
Figure 23D reconstruction of stents used in the CDF analysis. A: Palmaz genesis peripheral stent; B: Cook-Zilver vascular self-expanding stent.
Theoretical impact of the considered variables on the iliac arteries
| Variables | Theoretical impact on the vessel |
|---|---|
| Static pressure | Associated with the proliferation of vascular smooth muscle cells |
| Dynamic pressure | Associated with a variation of the blood flow velocity, which has been linked to a higher risk of re-stenosis |
| Reynolds number (Re) | High Re number indicates a disturbed blood flow and is associated with a hemodynamic turbulence, which causes endothelial dysfunction and thrombogenicity. |
| Vorticity magnitude | High in the presence of a severe stenosis. A high vorticity magnitude, especially in a bifurcation lesion, affects both the blood flow velocity and vorticity, promoting endothelial dysfunction and/or thrombogenicity. |
| Stream function | Related to a change of the characteristic non-Newtonian fluid motion |
| Strain rate | Low levels have been related to an in-stent restenosis |
| Wall-shea> | High Wall-shear stress plays a major role in both generation, progression and destabilisation of atherosclerotic plaques |
Area weighted average analysis of the entire physiologic models among different Carrefour angle
| Physiologic Model | |||
|---|---|---|---|
| α=70° | α=45° | α=30° | |
| Static pressure (Pa) [mmHg] | 18759.02[140.69] | 18734.96 [140.51] | 18677.71 [140.08] |
| Reynold number | 38.94 | 24.93 | 17.39 |
| Vorticity magnitude (1/s) | 892.50 | 1293.93 | 1437.32 |
| Stream function (kg/s) | 1.27 | 0.63 | 0.39 |
| Strain rate (1/s) | 912.17 | 1308.06 | 1450.0 |
| Wall shear stress (Pa) | 0.93 | 1.21 | 1.20 |
| Skin friction coefficient | 0.004 | 0.006 | 0.006 |
Area weighted average analysis of the entire pathologic models among different Carrefour angle
| Pathologic model | |||
|---|---|---|---|
| α=70° | α=45° | α=30° | |
| Static pressure (Pa) [mmHg] | 19414.14 | 19180.85 | 19150.75 |
| Reynold number | 48.87 | 29.51 | 20.06 |
| 35.18 | 8.52 | 12.28 | |
| 27.99 | 15.36 | 12.47 | |
| Vorticity magnitude (1/s) | 1654.32 | 2448.30 | 2412.36 |
| 10077.59 | 16993.16 | 15228.56 | |
| 11081.10 | 14052.73 | 13925.36 | |
| Stream function (kg/s) | 1.65 | 0.78 | 0.51 |
| Strain rate (1/s) | 1753.83 | 2592.02 | 2480.50 |
| Wall shear stress (Pa) | 2.41 | 3.20 | 2.73 |
| 55.06 | 69.84 | 65.80 | |
| 55.81 | 59.74 | 60.82 | |
| Skin friction coefficient | 0.012 | 0.016 | 0.014 |
Net area-weighted average comparison of fluid dynamic parameters
| Angle and stenting techniques | Stent | Static pressure (Pa) [mmHg] | Reynolds number | Vorticity magnitude (1/s) | Stream function (kg/s) | Strain rate (1/s) | Wall shear (Pa) | Skin friction coefficient |
|---|---|---|---|---|---|---|---|---|
| α=70° | ||||||||
| SE | 18757.07[140.67] | 38.17 | 881.63 | 1.25 | 900.85 | 0.92 | 0.004 | |
| BE | 18757.92[140.68] | 38.58 | 884.58 | 1.26 | 904.04 | 0.92 | 0.004 | |
| SE | 18754.77[140.66] | 37.49 | 860.79 | 1.23 | 879.74 | 0.89 | 0.004 | |
| BE | 18755.89[140.66] | 37.85 | 868.73 | 1.24 | 887.74 | 0.90 | 0.004 | |
| α =45° | ||||||||
| SE | 18733.86[140.50] | 24.48 | 1271.44 | 0.62 | 1285.24 | 1.92 | 0.006 | |
| BE | 18734.34[140.50] | 24.70 | 1282.66 | 0.63 | 1296.62 | 1.20 | 0.006 | |
| SE | 18732.91[140.49] | 24.04 | 1224.90 | 0.61 | 1262.46 | 1.16 | 0.006 | |
| BE | 18733.38[140.50] | 24.26 | 1260.21 | 0.62 | 1273.84 | 1.18 | 0.006 | |
| α =30° | ||||||||
| SE | 18678.44[140.08] | 17.08 | 1412.52 | 0.38 | 1425.92 | 1.18 | 0.006 | |
| BE | 18678.13[140.08] | 17.23 | 1424.97 | 0.38 | 1438.47 | 1.19 | 0.006 | |
| SE | 18679.71[140.09] | 16.77 | 1387.90 | 0.37 | 1401.07 | 1.16 | 0.006 | |
| BE | 18678.83[140.09] | 16.93 | 1400.19 | 0.38 | 1413.48 | 1.17 | 0.006 |
BE: balloon-expandable; SE: self-expandable.
Percentage deviation from the physiologic values of fluid parameters after stenting
| Δ% | Δ% | Δ% | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| α=70 | α=45 | α=30 | ||||||||||
| HK | LK | HK | LK | HK | LK | |||||||
| SE | BE | SE | BE | SE | BE | SE | BE | SE | BE | SE | BE | |
| Static pressure (Pa) | 0.01 | 0.01 | 0.02 | 0.02 | 0.01 | 0.00 | 0.01 | 0.01 | 0.00 | 0.00 | 0.01 | 0.01 |
| Reynolds number | 1.98 | 0.92 | 3.72 | 2.80 | 1.81 | 0.92 | 3.57 | 2.69 | 1.78 | 0.92 | 3.57 | 2.65 |
| Vorticity magnitude (1/s) | 1.22 | 0.89 | 3.55 | 2.66 | 1.74 | 0.87 | 3.47 | 2.61 | 1.73 | 0.89 | 3.44 | 2.58 |
| Stream function (kg/s) | 1.57 | 0.79 | 3.15 | 2.36 | 1.59 | 0.0 | 3.17 | 1.59 | 2.56 | 2.56 | 5.13 | 2.56 |
| Strain rate (1/s) | 1.21 | 0.89 | 3.57 | 2.68 | 1.74 | 0.84 | 3.49 | 2.62 | 1.66 | 0.80 | 3.37 | 2.52 |
| Wall shear (Pa) | 1.08 | 1.08 | 4.30 | 3.23 | 5.68 | 0.83 | 4.13 | 2.48 | 1.67 | 0.83 | 3.33 | 2.50 |
| Skin friction coefficient | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
BE: balloon-expandable; HK: High kissing; LK: Low kissing; SE: self-expandable.