Abstract
Background The aim of the study was to present dosimetric comparison of image guided high-dose-rate brachytherapy (IGBT) with volumetric modulated arc therapy (VMAT) for head and neck cancer regarding conformity of dose distribution to planning target volume (PTV) and doses to organs at risk (OARs). Patients and methods Thirty-eight consecutive patients with T1-4 mobile tongue, floor of mouth and base of tongue cancer treated with IGBT were selected. For these patients additional VMAT treatment plans were also prepared using identical computed tomography data. OARs and PTV related parameters (e.g. V98, D0.1cm3, Dmean, etc.) were compared. Results Mean V98 of the PTV was 90.2% vs. 90.4% (p > 0.05) for IGBT and VMAT, respectively. Mean D0.1cm3 to the mandible was 77.0% vs. 85.4% (p < 0.05). Dmean to ipsilateral and contralateral parotid glands was 4.6% vs. 4.6% and 3.0% vs. 3.9% (p > 0.05). Dmean to ipsilateral and contralateral submandibular glands was 16.4% vs. 21.9% (p > 0.05) and 8.2% vs. 16.9% (p < 0.05), respectively. Conclusions Both techniques showed excellent target coverage. With IGBT dose to normal tissues was lower than with VMAT. The results prove the superiority of IGBT in the protection of OARs and the important role of this invasive method in the era of new external beam techniques.Entities:
Keywords: dosimetric comparison; head and neck cancers; image guided high-dose-rate brachytherapy; volumetric modulated arc therapy
Mesh:
Year: 2018 PMID: 30422804 PMCID: PMC6287174 DOI: 10.2478/raon-2018-0042
Source DB: PubMed Journal: Radiol Oncol ISSN: 1318-2099 Impact factor: 2.991
Dosimetry of PTV
| IGBT | VMAT | ||
|---|---|---|---|
| Parameters | n=38 | n=38 | |
| mean S.D | mean S.D | ||
| V95 (%) | 92.1 3.0 | 98.4 0.9 | <0.05 |
| V98 (%) | 90.2 3.2 | 90.4 3.7 | >0.05 |
| V100 (%) | 89.0 3.4 | 76.7 8.9 | <0.05 |
| D90 (%) | 98.6 4.7 | 98.2 0.8 | <0.05 |
| D100 (%) | 58.6 9.0 | 87.0 3.2 | <0.05 |
Abbreviations: S.D., standard deviation; PTV, planning target volume; IGBT, image guided high-dose-rate brachytherapy; VMAT, volumetric modulated arc therapy; n, number of patients for analysis; VX, relative volume of the PTV receiving at least X% of the PD; DX, minimum relative dose of the PD delivered to X% of the PTV.
Dosimetry of submandibular gland
| IGBT | VMAT | ||||
|---|---|---|---|---|---|
| Parameters | |||||
| mean | S.D | mean | S. D | ||
| ipsilateral side | |||||
| Dmean (%), n=20 | 16.4 | 10.7 | 21.9 | 19.9 | >0.05 |
| D0.1cm3 (%), n=20 | 27.4 | 15.6 | 39.9 | 23.3 | >0.05 |
| D1cm3 (%), n=18 | 19.4 | 11.2 | 27.2 | 17.6 | >0.05 |
| D2cm3 (%), n=17 | 16.1 | 9.4 | 20.8 | 14.7 | >0.05 |
| D10 (%), n=20 | 22.6 | 13.9 | 33.2 | 23.0 | >0.05 |
| D30 (%), n=20 | 18.3 | 11.7 | 25.8 | 21.9 | >0.05 |
| D50 (%), n=20 | 15.7 | 10.4 | 21.0 | 20.9 | >0.05 |
| V10 (%), n=20 | 61.3 | 38.6 | 63.9 | 33.6 | >0.05 |
| V30 (%), n=20 | 14.5 | 28.0 | 30.1 | 38.7 | >0.05 |
| V50 (%), n=20 | 1.4 | 3.7 | 14.1 | 27.4 | >0.05 |
| contralateral side | |||||
| Dmean (%), n=34 | 8.2 | 4.8 | 16.9 | 10.8 | <0.05 |
| D0.1cm3 (%), n=34 | 13.4 | 5.3 | 29.7 | 12.0 | <0.05 |
| D1cm3 (%), n=32 | 9.4 | 3.2 | 21.7 | 8.6 | <0.05 |
| D2cm3 (%), n=32 | 8.1 | 2.9 | 18.3 | 8.3 | <0.05 |
| D10 (%), n=34 | 11.1 | 5.6 | 25.3 | 12.2 | <0.05 |
| D30 (%), n=34 | 9.2 | 5.1 | 20.4 | 11.4 | <0.05 |
| D50 (%), n=34 | 8.0 | 4.7 | 16.7 | 11.4 | <0.05 |
| V10 (%), n=34 | 26.0 | 30.2 | 69.9 | 27.5 | <0.05 |
| V30 (%), n=34 | 1.2 | 7.0 | 14.1 | 25.1 | <0.05 |
| V50 (%), n=34 | 0.0 | 0.0 | 2.7 | 12.1 | N.A |
Abbreviations: S.D., standard deviation; IGBT, image guided high-dose-rate brachytherapy; VMAT, volumetric modulated arc therapy; n, number of the patients for analysis; Dmean, mean relative dose of the PD delivered to the organs; DXcm3, minimum relative dose of the PD delivered to most exposed X cm3 of the organs; DX, minimum relative dose of the PD delivered to X% of the organs; VX, relative volume of the organs receiving at least X% of the PD, N.A., not available.
in fifteen patients the submandibular glands were resected by operation and three patients were not evaluated because of central implantation.
two and three patients, respectively, were additionally excluded from the analysis of D1cm3 and D2cm3 because the volume was too small.
in one patient the submandibular gland was resected by operation and three patients were not evaluated because of central implantation.
two and two patients, respectively, were additionally excluded from the analysis of D1cm3 and D2cm3 because the volume was too small.
Dosimetry of parotid gland
| IGBT | VMAT | ||||
|---|---|---|---|---|---|
| Parameters | |||||
| mean | S.D | mean | S. D | ||
| ipsilateral side (n=34[ | |||||
| Dmean (%) | 4.6 | 1.4 | 4.6 | 2.6 | >0.05 |
| D0.1cm3 (%) | 11.2 | 2.8 | 18.0 | 7.1 | <0.05 |
| D1cm3 (%) | 8.1 | 2.1 | 12.9 | 6.3 | <0.05 |
| D2cm3 (%) | 7.0 | 2.0 | 10.5 | 5.7 | <0.05 |
| D10 (%) | 7.3 | 2.1 | 11.2 | 5.6 | <0.05 |
| D30 (%) | 5.5 | 1.6 | 5.5 | 4.0 | >0.05 |
| D50 (%) | 4.5 | 1.3 | 3.0 | 3.1 | <0.05 |
| V10 (%) | 3.1 | 4.0 | 18.0 | 16.9 | <0.05 |
| V30 (%) | 0.0 | 0.0 | 0.7 | 3.9 | N.A |
| V50 (%) | 0.0 | 0.0 | 0.1 | 0.5 | N.A |
| contralateral side (n=35[ | |||||
| Dmean (%) | 3.0 | 0.9 | 3.9 | 2.1 | >0.05 |
| D0.1cm3 (%) | 8.9 | 2.1 | 15.3 | 5.9 | <0.05 |
| D1cm3 (%) | 5.9 | 1.6 | 10.8 | 5.9 | <0.05 |
| D2cm3 (%) | 4.9 | 1.5 | 9.1 | 5.4 | <0.05 |
| D10 (%) | 5.4 | 1.3 | 9.9 | 4.4 | <0.05 |
| D30 (%) | 4.0 | 1.0 | 4.9 | 3.7 | >0.05 |
| D50 (%) | 3.2 | 0.8 | 2.2 | 2.3 | <0.05 |
| V10 (%) | 0.5 | 0.3 | 14.2 | 13.2 | <0.05 |
| V30 (%) | 0.0 | 0.0 | 0.8 | 4.7 | N.A |
| V50 (%) | 0.0 | 0.0 | 0.2 | 1.3 | N.A |
Abbreviations: S.D., standard deviation; IGBT, image guided high-dose-rate brachytherapy; VMAT, volumetric modulated arc therapy; n, number of patients for analysis; Dmean, mean relative dose of the PD delivered to the organs; DXcm3, minimum relative dose of the PD delivered to most exposed X cm3 of the organs; DX, minimum relative dose of the PD delivered to X% of the organs; VX, relative volume of the organs receiving at least X% of the PD; N.A., not available.
in one patient the parotid gland was not detected because it was excluded from the field-of-view of the CT scans, and in three patients parotid glands were not evaluated because of central implantation.
three patients were not evaluated because of central implantation.
Dosimetry of mandible and spinal cord
| IGBT | VMAT | ||||
|---|---|---|---|---|---|
| Parameters | |||||
| mean | S. D | mean | S.D | ||
| Mandible, n=38 | |||||
| D0.1cm3 (%) | 77.0 | 17.2 | 85.4 | 7.9 | <0.05 |
| D1cm3 (%) | 56.9 | 13.4 | 74.5 | 9.6 | <0.05 |
| D2cm3 (%) | 48.4 | 12.2 | 68.4 | 9.5 | <0.05 |
| Spinal cord, n=37 | |||||
| D0.1cm3 (%) | 9.7 | 2.6 | 12.3 | 4.1 | <0.05 |
| D1cm3 (%) | 6.8 | 2.0 | 10.8 | 3.7 | <0.05 |
| D2cm3 (%) | 5.9 | 1.9 | 10.0 | 3.6 | <0.05 |
Abbreviations: S.D., standard deviation; IGBT, image guided high-dose-rate brachytherapy; VMAT, volumetric modulated arc therapy; n, number of patients for analysis; DXcm3, minimum relative dose of the PD delivered to most exposed X cm3 of the organs.
in one patient the spinal cord was not detected because it was excluded from the field-of-view of the CT scans.
Figure 1Representative dose distribution of (A) image guided high-dose-rate brachytherapy (IGBT) and (B) volumetric modulated arc therapy (VMAT).