Prosthesis-patient mismatch after transcatheter aortic valve implantation: prevalence and prognostic impact with respect to baseline left ventricular function.

Niklas Schofer1, Florian Deuschl, Nicole Rübsamen, Johanna Skibowski, Moritz Seiffert, Lisa Voigtländer, Andreas Schaefer, Yvonne Schneeberger, Johannes Schirmer, Hermann Reichenspurner, Stefan Blankenberg, Lenard Conradi, Ulrich Schäfer.   

Abstract

AIMS: We aimed to assess the prevalence and features of prosthesis-patient mismatch (PPM) following transcatheter aortic valve implantation (TAVI) and its prognostic impact considering baseline left ventricular ejection fraction (LVEF). METHODS AND
RESULTS: Data from 1,309 patients undergoing TAVI for severe aortic stenosis were derived from a single-centre dedicated TAVI registry. PPM was assessed according to echocardiography at discharge and was defined in accordance with VARC-2. Median follow-up time was 2.03 years. Moderate and severe PPM was detected in 22.9% and 12.9%, respectively. Patients with severe PPM had smaller annuli and more often received transcatheter heart valve (THV) sizes ≤23 mm. Supra-annular THV design showed the lowest rate of PPM. In patients with LVEF <40%, but not in those with LVEF ≥40%, severe PPM was associated with an increased three-year mortality rate (no vs. severe PPM for LVEF ≥40%: 34.6% vs. 29.5%, p=0.96; LVEF <40%: 45.1% vs. 68.0%, p=0.041) and was independently predictive of all-cause mortality according to multivariate analysis in these patients (HR 2.97; 95% CI: 1.58-5.59, p<0.001).
CONCLUSIONS: The presence of severe PPM depends on annular dimensions and THV size and design and is an independent predictor of mortality in patients with reduced LVEF. Hence, the risk of PPM should be considered within the process of THV selection.

Entities:  

Mesh:

Year:  2019        PMID: 30418159     DOI: 10.4244/EIJ-D-18-00827

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  7 in total

Review 1.  Prosthesis-patient mismatch after transcatheter aortic valve implantation.

Authors:  Masaki Miyasaka
Journal:  Cardiovasc Interv Ther       Date:  2022-06-16

2.  Impact of Prosthesis-Patient Mismatch on 1-Year Outcomes after Transcatheter Aortic Valve Implantation: Meta-analysis of 71,106 Patients.

Authors:  Michel Pompeu Barros Oliveira Sá; Luiz Rafael Pereira Cavalcanti; Felipe Augusto Santos Sarargiotto; Álvaro Monteiro Perazzo; Sérgio da Costa Rayol; Roberto Gouveia Silva Diniz; Frederico Browne Correia Araújo Sá; Alexandre Motta Menezes; Ricardo Carvalho Lima
Journal:  Braz J Cardiovasc Surg       Date:  2019-06-01

3.  Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve.

Authors:  Haruka Kameshima; Masaki Izumo; Tomomi Suzuki; Hiroshi Ohara; Yukio Sato; Mika Watanabe; Shingo Kuwata; Kazuaki Okuyama; Ryo Kamijima; Manabu Takai; Seisyou Kou; Yasuhiro Tanabe; Tomoo Harada; Yoshihiro J Akashi
Journal:  Front Cardiovasc Med       Date:  2022-01-31

4.  Patient Prosthesis Mismatch After SAVR and TAVR.

Authors:  Sabine Bleiziffer; Tanja K Rudolph
Journal:  Front Cardiovasc Med       Date:  2022-03-30

5.  Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis.

Authors:  Max Potratz; Kawa Mohemed; Hazem Omran; Lasha Gortamashvili; Kai Peter Friedrichs; Werner Scholtz; Smita Scholtz; Volker Rudolph; Cornelia Piper; Tomasz Gilis-Januszewski; René Schramm; Nobuyuki Furukawa; Jan Gummert; Sabine Bleiziffer; Tanja Katharina Rudolph
Journal:  J Clin Med       Date:  2022-08-05       Impact factor: 4.964

Review 6.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04

7.  Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves.

Authors:  Lisa Voigtländer; Won-Keun Kim; Victor Mauri; Alina Goßling; Matthias Renker; Atsushi Sugiura; Matthias Linder; Tobias Schmidt; Niklas Schofer; Dirk Westermann; Hermann Reichenspurner; Georg Nickenig; Stefan Blankenberg; Christian Hamm; Lenard Conradi; Matti Adam; Jan-Malte Sinning; Moritz Seiffert
Journal:  Clin Res Cardiol       Date:  2021-08-13       Impact factor: 5.460

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.