Literature DB >> 30414536

Using upstream oxidants to minimize surface biofouling and improve hydraulic performance in GAC biofilters.

Glen Andrew de Vera1, Chance Lauderdale2, Christina L Alito3, Jennifer Hooper4, Eric C Wert5.   

Abstract

The combination of biological growth and particle loading can adversely affect hydraulic performance in drinking water biofilters. In this study, upstream oxidant addition was used to distribute biologically-derived filter clogging in granular activated carbon (GAC) biofilters. Oxidant penetration was assessed during pilot-scale operation and backwashing of dual media (GAC/sand) and multimedia (GAC/anthracite/sand) biofilters. Influent chlorine (HOCl), monochloramine (NH2Cl), and hydrogen peroxide (H2O2) residuals were optimized to react with the GAC surface in the upper portion of the filter media bed (depth < 0.5 m) to attenuate biomass development. As the oxidant residual was quenched by surface-mediated reaction with the filter media, biomass growth was promoted deeper in the filter bed (depth > 0.5 m). The oxidant-induced effects on biomass and hydraulic performance were monitored through measurements of adenosine triphosphate (ATP) and head loss accumulation at different media depths. Addition of oxidants (e.g., 0.6 mg Cl2/L HOCl) could decrease terminal head loss by 20% in dual media filters and 40% in multimedia filters. These hydraulic benefits were achieved without significantly affecting removal of assimilable organic carbon (AOC), total organic carbon (TOC), turbidity, and particle counts. Oxidant type, residual concentration, media type, media age, and media depth influenced the passage of oxidant residuals and distribution of filter biomass. When oxidants were added during backwashing, oxidant residual was quenched through the bed depth from a combination of reactions with GAC media and biofilm degradation. This attenuation of residual oxidant may prevent the oxidant residual from penetrating the entire bed depth, potentially compromising backwashing objectives.
Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Biofiltration; Biological Filtration; Filter clogging; Granular Activated Carbon (GAC); Head loss; Oxidants

Mesh:

Substances:

Year:  2018        PMID: 30414536     DOI: 10.1016/j.watres.2018.10.085

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Assessing Pretreatment Effectiveness for Particulate, Organic and Biological Fouling in a Full-Scale SWRO Desalination Plant.

Authors:  Almotasembellah Abushaban; Sergio G Salinas-Rodriguez; Delia Pastorelli; Jan C Schippers; Subhanjan Mondal; Said Goueli; Maria D Kennedy
Journal:  Membranes (Basel)       Date:  2021-02-27

Review 2.  Microbial ecology of biofiltration used for producing safe drinking water.

Authors:  Xi Bai; Inez J T Dinkla; Gerard Muyzer
Journal:  Appl Microbiol Biotechnol       Date:  2022-06-30       Impact factor: 5.560

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.