Literature DB >> 30387868

Evaluation of marginal and internal fit of acrylic bridges using optical coherence tomography.

Hiba Al-Imam1,2, Stavroula Michou2, Ana R Benetti2, Klaus Gotfredsen1.   

Abstract

BACKGROUND: The potential of non-invasive optical coherence tomography (OCT) as a tool for assessment of fit of indirect reconstructions is not fully explored.
OBJECTIVES: The objectives were to investigate the feasibility and validity of OCT, and to measure the internal and marginal fit of acrylic bridges fabricated using direct and indirect digitalisation.
METHODS: The accuracy of the employed swept source OCT (wavelength: 1310 nm) was assessed by comparing with an object with known dimensions. Validity was assessed by measuring an OCT measurements on replica, mimicking the cement film thickness, with stereomicroscopic measurements. The reconstructions were placed on the abutments without cementation. The internal and marginal fit of acrylic bridges from direct and indirect digitalisation techniques were then assessed by obtaining 5 OCT B-scans per abutment tooth at pre-defined positions located 250 μm apart. The marginal and internal cement gaps were measured using image-processing software (ImageJ). Mean and standard deviation were calculated for both groups and t test assuming unequal variances was carried out. The level of significance was defined at 0.05.
RESULTS: A strong linear correlation (r = 0.865) between OCT and stereomicroscopy was found. T test showed significantly (P < 0.01) better internal fit of bridges made from indirect digitalisation, but no difference in marginal fit.
CONCLUSION: OCT is a feasible and valid tool for investigating internal and marginal fit of acrylic dental reconstructions. Better internal fit was observed in bridges fabricated using the direct digitalisation technique. No difference in marginal fit was found between the two fabrication methods.
© 2018 John Wiley & Sons Ltd.

Keywords:  accuracy; acrylic resins; dental internal fit; dental marginal fit; optical coherence tomography; replica technique

Mesh:

Year:  2018        PMID: 30387868     DOI: 10.1111/joor.12746

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  3 in total

1.  Evaluation of Internal Fit and Marginal Adaptation of Provisional Crowns Fabricated with Three Different Techniques.

Authors:  Jie Wu; Hongjun Xie; Alireza Sadr; Kwok-Hung Chung
Journal:  Sensors (Basel)       Date:  2021-01-22       Impact factor: 3.576

2.  Optical coherence tomography systems for evaluation of marginal and internal fit of ceramic reconstructions.

Authors:  Hiba Al-Imam; Ana R Benetti; Pete Tomlins; Klaus Gotfredsen
Journal:  Biomater Investig Dent       Date:  2022-09-29

3.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.