Audrey E Kaufman1, Alison N Pruzan1, Ching Hsu2, Sarayu Ramachandran1, Adam Jacobi1, Indravadan Patel1, Lee Schwocho1, Michele F Mercuri1, Zahi A Fayad1, Venkatesh Mani1.
Abstract
AIM: To evaluate reproducibility of pulmonary embolism (PE) clot volume quantification using computed tomography pulmonary angiogram (CTPA) in a multicenter setting.Entities:
Keywords: Arteries; Computed tomography angiography; Computer-assisted image analysis; Pulmonary embolism; Thrombolytic therapy
Year: 2018 PMID: 30386497 PMCID: PMC6205841 DOI: 10.4329/wjr.v10.i10.124
Source DB: PubMed Journal: World J Radiol ISSN: 1949-8470
Scanner Information and computed tomography pulmonary angiogram acquisition protocol from each scanner
| Academic Medical Center, Amsterdam, Netherlands | 1 | Siemens | Definition AS+ | 128 | 1 | 120 | 0.45 | Ultravist 300 |
| 2 | Siemens | Force | 384 | 1.5 | 90 | 0.55 | Ultravist 300 | |
| Azienda Ospedaliero Universitaria Ospedali Riuniti Di Ancona, Ancona, Italy | 3 | Philips | Brilliance 16 | 16 | 2 | 120 | 0.9 | Isovue 350 |
| Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy | 4 | GE | Optima CT660 | 128 | 0.625 | 120 | 1.375 | Ultravist 370 |
| Hôpital de la Cavale Blanche, Brest, France | 5 | Siemens | Definition AS + | 128 | 1 | 100 | 1.2 | Iomeron 400 |
| Cliniques Universitaires Saint-Luc, Brussels, Belgium | 6 | Philips | ICT Brilliance 64 | 256 | 1 | 120 | 0.797 | Iomeron 400 |
| CHU de Clermont-Ferrand, Clermont-Ferrand, France | 7 | GE | Revolution GSI | 64 | 0.625 | 120 | 1.375 | Ultravist 370 |
| Hospital Universitario Dr. Josep Trueta, Girona, Spain | 8 | Philips | Ingenuity CT | 64 | 1 | 120 | 0.952 | Omnipaque 350 |
| Medical University Graz, Graz, Austria | 9 | Toshiba | Aquilion64 | 64 | 0.5 | 120 | 1 | Optiray 350 |
| 10 | Toshiba | Aquilion64 | 64 | 0.5 | 120 | 1 | Iomeron 400 | |
| Universitätsmedizin Greifswald, Greifswald, Germany | 11 | Siemens | Sensation 16 | 16 | 1.5 | 120 | 1.2 | Iomeron 350 |
| Hopital Michallon - CHUGA, Grenoble, France | 12 | GE | Optima CT 660 | 128 | 0.625 | 100 | 0.984375 | Iomeron 350 |
| Leiden University Medical Center, Leiden, Netherlands | 13 | Toshiba | Aquilion ONE | 320 | 1 | 80 | 0.8129 | Ultravist 370 |
| UZ Gasthuisberg, Leuven, Belgium | 14 | Siemens | Definition Flash | 128 | 1 | 100 | 0.55 | Visipaque 320 |
| 15 | Siemens | Definition Flash | 128 | 1 | 100 | 0.55 | Visipaque 320 | |
| 16 | Siemens | Definition Flash | 128 | 1 | 100 | 0.55 | Visipaque 320 | |
| Cedars Sinai Medical Center, Los Angeles, United States | 17 | GE | LightSpeed VCT | 64 | 0.625 | 120 | 0.984375 | Omnipaque 350 |
| Hospital Universitario Ramon y Cajal, Madrid, Spain | 18 | Toshiba | Aquilion ONE | 320 | 0.5 | 100 | 1.375 | Iomeron 350 |
| Intercoastal Medical Group, Sarasota, United States | 19 | Siemens | Definition AS+ | 128 | 0.6 | 120 | 1.1 | Isovue 370 |
| CHU de St. Etienne, St. Etienne, France | 20 | Siemens | Definition DS | 64 | 1 | 120 | 1.2 | Xenetix 350 |
| Strasbourg University Hospital, Strasbourg, France | 21 | GE | Discovery CT750 HD | 64 | 0.625 | 100 | 1.375 | Iomeron 400 |
| 22 | Toshiba | Aquilion One | 320 | 1 | 100 | 0.8129 | Iomeron 400 | |
| Ospedale di Circolo, University of Insubria, Varese, Italy | 23 | Siemens | Sensation 40 | 40 | 0.75 | 100 | 1 | Iomeron 370 |
All images were obtained with dose modulation of tube current. Filter and reconstruction kernels varied.
Figure 1Schematic of segmental distribution of pulmonary arteries. MPA: Main pulmonary artery; RPA: Right pulmonary artery; TA: Truncus anterior; RILA: Right interlobar artery; RBT: Right basal trunk; RA1: Right upper lobe, apical; RA2: Right upper lobe, posterior; RA3: Right upper lobe, anterior; RA4: Right middle lobe, lateral; RA5: Right middle lobe, medial; RA6: Right lower lobe, superior; RA7: Right lower lobe, medial basal; RA8: Right lower lobe, anterior basal; RA9: Right lower lobe, lateral basal; RA10: Right lower lobe, posterior basal; LPA: Left pulmonary artery; LILA: Left interlobar artery; LBT: Left basal trunk; LA1: Left upper lobe, apical; LA2: Left upper lobe, posterior; LA3: Left upper lobe, anterior; LA4: Lingula, superior; LA5: Lingula, inferior; LA6: Left lower lobe, superior; LA7: Left lower lobe, medial basal; LA8: Left lower lobe, anterior basal; LA9: Left lower lobe, lateral basal; LA10: Left lower lobe, posterior basal.
Figure 2Computed tomography pulmonary angiogram images demonstrating segmentation of a saddle embolus in three orthogonal views (arrows).
Figure 3Total thrombus volume inter- and intra-observer reproducibility (A) Intra-class correlation coefficient (ICC) plot and (B) Bland Altman plot comparing the total PE thrombus volume results of the primary and secondary image analyst for the inter-observer reproducibility analysis (C) ICC plot and (D) Bland Altman plot comparing the total pulmonary embolism thrombus volume results of the first and second read of the primary image analyst for the intra-observer reproducibility analysis.
Figure 4Individual thrombus volume inter- and intra-observer reproducibility (A) Intra-class correlation coefficient (ICC) plot and (B) Bland Altman plot comparing the individual PE thrombus volumes results of the primary and secondary image analyst for the inter-observer reproducibility analysis (C) ICC plot and (D) Bland Altman plot comparing the individual pulmonary embolism thrombus volumes results of the first and second read of the primary image analyst for the intra-observer reproducibility analysis.
Figure 5Qanadli score inter- and intra-observer reproducibility (A) Intra-class correlation coefficient (ICC) plot and (B) Bland Altman plot comparing the Qanadli score results of the primary and secondary image analyst for the inter-observer reproducibility analysis (C) ICC plot and (D) Bland Altman plot comparing the results of the first and second read of the primary image analyst for the intra-observer reproducibility analysis of the PE obstruction index (Qanadli score).
Figure 6Modified Qanadli score inter- and intra-observer reproducibility (A) Intra-class correlation coefficient (ICC) plot and (B) Bland Altman plot comparing the modified Qanadli results of the primary and secondary image analyst for the inter-observer reproducibility analysis (C) ICC plot and (D) Bland Altman plot comparing the results of the first and second read of the primary image analyst for the intra-observer reproducibility analysis.
Figure 7Bland Altman analysis of total thrombus volume normalized to clot size (Mean vs Difference/Mean) for (A) intra and (B) inter observer analysis.