PURPOSE: Isotropic diffusion encoding efficiently encodes additional microstructural information in combination with conventional linear diffusion encoding. However, the gradient-intensive isotropic diffusion waveforms generate significant eddy currents, which cause image distortions. The purpose of this study is to present a method for designing isotropic diffusion encoding waveforms with intrinsic eddy current nulling.
METHODS: Eddy current nulled gradient waveforms were designed using a constrained optimization waveform for a 3T GE Premier MRI system. Encoding waveforms were designed for a variety of eddy current null times and sequence timings to evaluate the achievable b-value. Waveforms were also tested with both eddy current nulling and concomitant field compensation. Distortion reduction was tested in both phantoms and the in vivo human brain.
RESULTS: The feasibility of isotropic diffusion encoding with intrinsic correction of eddy current distortion and signal bias from concomitant fields was demonstrated. The constrained optimization algorithm produced gradient waveforms with the specified eddy current null times. The reduction in the achievable diffusion weighting was dependent on the number of eddy current null times. A reduction in the eddy current-induced image distortions was observed in both phantoms and in vivo human subjects.
CONCLUSION: The proposed framework allows the design of isotropic diffusion-encoding sequences with reduced image distortion.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MRI; Maxwell terms; concomitant fields; eddy current nulling; isotropic diffusion encoding; microstructure; q-space trajectory imaging

Mesh:

Year:  2018        PMID: 30368913      PMCID: PMC6347544          DOI: 10.1002/mrm.27539

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  51 in total

1.  Gradient coil design using active magnetic screening.

Authors:  R Bowtell; P Mansfield
Journal:  Magn Reson Med       Date:  1991-01       Impact factor: 4.668

2.  Extension of the double-wave-vector diffusion-weighting experiment to multiple concatenations.

Authors:  Jürgen Finsterbusch
Journal:  J Magn Reson       Date:  2009-02-13       Impact factor: 2.229

3.  Compartment size estimation with double wave vector diffusion-weighted imaging.

Authors:  Martin A Koch; Jürgen Finsterbusch
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

4.  Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement.

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1995-06-01

5.  Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MR.

Authors:  Noam Shemesh; Yoram Cohen
Journal:  Magn Reson Med       Date:  2011-02-08       Impact factor: 4.668

6.  Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted MRI.

Authors:  Eric Aliotta; Holden H Wu; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2016-02-22       Impact factor: 4.668

Review 7.  From single-pulsed field gradient to double-pulsed field gradient MR: gleaning new microstructural information and developing new forms of contrast in MRI.

Authors:  Noam Shemesh; Evren Ozarslan; Michal E Komlosh; Peter J Basser; Yoram Cohen
Journal:  NMR Biomed       Date:  2010-08       Impact factor: 4.044

8.  Diffusion/perfusion MR imaging of acute cerebral ischemia.

Authors:  J Kucharczyk; J Mintorovitch; H S Asgari; M Moseley
Journal:  Magn Reson Med       Date:  1991-06       Impact factor: 4.668

Review 9.  FSL.

Authors:  Mark Jenkinson; Christian F Beckmann; Timothy E J Behrens; Mark W Woolrich; Stephen M Smith
Journal:  Neuroimage       Date:  2011-09-16       Impact factor: 6.556

Review 10.  Conventions and nomenclature for double diffusion encoding NMR and MRI.

Authors:  Noam Shemesh; Sune N Jespersen; Daniel C Alexander; Yoram Cohen; Ivana Drobnjak; Tim B Dyrby; Jurgen Finsterbusch; Martin A Koch; Tristan Kuder; Fredrik Laun; Marco Lawrenz; Henrik Lundell; Partha P Mitra; Markus Nilsson; Evren Özarslan; Daniel Topgaard; Carl-Fredrik Westin
Journal:  Magn Reson Med       Date:  2015-09-29       Impact factor: 4.668

View more
  10 in total

1.  Optimization methods for magnetic resonance imaging gradient waveform design.

Authors:  Matthew J Middione; Michael Loecher; Kévin Moulin; Daniel B Ennis
Journal:  NMR Biomed       Date:  2020-04-27       Impact factor: 4.044

Review 2.  Tractography methods and findings in brain tumors and traumatic brain injury.

Authors:  Fang-Cheng Yeh; Andrei Irimia; Dhiego Chaves de Almeida Bastos; Alexandra J Golby
Journal:  Neuroimage       Date:  2021-10-18       Impact factor: 6.556

3.  Nonparametric 5D D-R2 distribution imaging with single-shot EPI at 21.1 T: Initial results for in vivo rat brain.

Authors:  Jens T Rosenberg; Samuel C Grant; Daniel Topgaard
Journal:  J Magn Reson       Date:  2022-06-15       Impact factor: 2.734

Review 4.  Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact.

Authors:  Qiuyun Fan; Cornelius Eichner; Maryam Afzali; Lars Mueller; Chantal M W Tax; Mathias Davids; Mirsad Mahmutovic; Boris Keil; Berkin Bilgic; Kawin Setsompop; Hong-Hsi Lee; Qiyuan Tian; Chiara Maffei; Gabriel Ramos-Llordén; Aapo Nummenmaa; Thomas Witzel; Anastasia Yendiki; Yi-Qiao Song; Chu-Chung Huang; Ching-Po Lin; Nikolaus Weiskopf; Alfred Anwander; Derek K Jones; Bruce R Rosen; Lawrence L Wald; Susie Y Huang
Journal:  Neuroimage       Date:  2022-02-23       Impact factor: 7.400

Review 5.  What's new and what's next in diffusion MRI preprocessing.

Authors:  Chantal M W Tax; Matteo Bastiani; Jelle Veraart; Eleftherios Garyfallidis; M Okan Irfanoglu
Journal:  Neuroimage       Date:  2021-12-26       Impact factor: 7.400

6.  In vivo magnetic resonance imaging and spectroscopy. Technological advances and opportunities for applications continue to abound.

Authors:  Peter van Zijl; Linda Knutsson
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

7.  Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems.

Authors:  Filip Szczepankiewicz; Jens Sjölund; Freddy Ståhlberg; Jimmy Lätt; Markus Nilsson
Journal:  PLoS One       Date:  2019-03-28       Impact factor: 3.240

8.  A gradient optimization toolbox for general purpose time-optimal MRI gradient waveform design.

Authors:  Michael Loecher; Matthew J Middione; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2020-07-07       Impact factor: 4.668

9.  Toward nonparametric diffusion- T 1 characterization of crossing fibers in the human brain.

Authors:  Alexis Reymbaut; Jeffrey Critchley; Giuliana Durighel; Tim Sprenger; Michael Sughrue; Karin Bryskhe; Daniel Topgaard
Journal:  Magn Reson Med       Date:  2020-12-10       Impact factor: 4.668

10.  MR Fingerprinting with b-Tensor Encoding for Simultaneous Quantification of Relaxation and Diffusion in a Single Scan.

Authors:  Maryam Afzali; Lars Mueller; Ken Sakaie; Siyuan Hu; Yong Chen; Filip Szczepankiewicz; Mark A Griswold; Derek K Jones; Dan Ma
Journal:  Magn Reson Med       Date:  2022-06-17       Impact factor: 3.737

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.