Literature DB >> 30368236

Sick building syndrome and associated risk factors among the population of Gondar town, northwest Ethiopia.

Haileab Belachew1, Yibeltal Assefa1, Gebisa Guyasa1, Jember Azanaw1, Tsegaye Adane1, Henok Dagne1, Zemichael Gizaw2.   

Abstract

BACKGROUND: Sick building syndrome (SBS) consists of a group of mucosal, skin, and general symptoms temporally related to residential and office buildings of unclear causes. These symptoms are common in the general population. However, SBS symptoms and their contributing factors are poorly understood, and the community associates it with bad sprits. This community-based cross-sectional study was, therefore, conducted to assess the prevalence and associated factors of SBS in Gondar town.
METHODS: A community-based cross-sectional study was conducted from March to April 2017. A total of 3405 study subjects were included using multistage and systematic random sampling techniques. A structured questionnaire and observational checklists were used to collect data. SBS was assessed by 24 building-related symptoms and confirmed by five SBS confirmation criteria. Multivariable binary logistic regression analysis was used to identify factors associated with SBS on the basis of adjusted odds ratio (AOR) with 95% confidence interval (CI) and p < 0.05. The Hosmer and Lemeshow goodness of fit test was used to check model fitness, and variance inflation factor (VIF) was also used to test interactions between variables.
RESULTS: The prevalence of SBS in Gondar town was 21.7% (95% CI = 20.3-23.0%). Of this, the mucosal symptoms account for 64%, the general symptoms account for 54%, and the skin symptoms account for 10%. From study participants who reported SBS symptoms, 44% had more than one symptom. Headache (15.7%), asthma (8.3%), rhinitis (8.0%), and dizziness (7.5%) were the commonest reported symptoms. SBS was significantly associated with fungal growth in the building [AOR = 1.25, 95% CI = (1.05, 1.49)], unclean building [AOR = 1.26, 95% CI = (1.03, 1.55)], houses with no functional windows [AOR = 1.35, 95% CI = (1.12, 1.63)], houses with no fan [AOR = 1.90, 95% CI = (1.22, 2.96)], utilization of charcoal as a cooking energy source [AOR = 1.40, 95% CI = (1.02, 1.91)], cooking inside the living quarters [AOR = 1.31, 95% CI = (1.09, 1.58)], and incensing and joss stick use [AOR = 1.48, 95% CI = (1.23, 1.77)].
CONCLUSION: The prevalence of SBS in Gondar town was high, and significant proportion of the population had more than one SBS symptom. Headache, asthma, rhinitis, and dizziness were the commonest reported SBS symptoms. Fungal growth, cleanliness of the building, availability of functional windows, availability of fan in the living quarters, using charcoal as a cooking energy source, cooking inside the quarters, and incensing habit or joss stick use were identified as factors associated with SBS. Improving the sanitation of the living environment and housekeeping practices of the occupants is useful to minimize the prevalence of SBS.

Entities:  

Keywords:  Building-related symptoms; Gondar town; Residential buildings; Sick building syndromes

Mesh:

Year:  2018        PMID: 30368236      PMCID: PMC6204270          DOI: 10.1186/s12199-018-0745-9

Source DB:  PubMed          Journal:  Environ Health Prev Med        ISSN: 1342-078X            Impact factor:   3.674


Background

Housing is one of the basic needs of a human being and fundamental for wellbeing [1, 2]. People spend more than 90% of their time indoors [3]. Housing increasingly becomes a major public health concern. For many years, the housing environment has been acknowledged as one of the main settings that affect human health. Indoor air quality, home safety, noise, humidity and mold growth, indoor temperatures, asbestos, lead, radon, volatile organic compounds (VOC), lack of hygiene and sanitation equipment, and crowding are some of the most relevant possible health threats in dwellings [4-6]. Physical, mental, and social health is affected by the living conditions. The quality of housing conditions plays a decisive role in the health status of the residents. Many health problems are either directly or indirectly related to the building itself, because of the construction materials that were used and the equipment installed or the size or design of the individual dwellings [4, 7]. These building-related health problems are categorized in building-related diseases and sick building syndrome (SBS) [8]. SBS consists of a group of mucosal, skin, and general symptoms that are temporally related to residential and office buildings. SBS comprises a group of symptoms of unclear causes divided into mucous membrane symptoms related to the eyes, nose, throat, and dry skin, together with what are often called general symptoms of headache and lethargy [7-9]. SBS can be influenced by a variety of factors, like building-related factors (air-conditioned building, fresh air ventilation rates, indoor temperature, poor building service maintenance and cleaning, relative humidity) [7, 10–13], environmental factors and pollutants [VOCs (formaldehyde, solvents, etc.), carbon monoxide (stoves, heaters, and furnaces), dust and fibers (asbestosis, fiberglass, dirt), bio-aerosols (bacteria, molds, viruses, pollen, dust, mites, animal danders, animal excreta), trapped outdoor pollutants (vehicle or industrial exhausts), physical factors (lighting, vibration, noise, temperature, crowding, photo duplication)] [14-17], and personal factors (gender, history of being allergic, job dissatisfaction, cigarette smoke, increased use of computers) [18-22]. SBS symptoms are common in the general population. However, SBS symptoms and their contributing factors are poorly understood, especially in developing countries including Ethiopia. The community associates SBS with bad spirit. This community-based cross-sectional study was, therefore, conducted to assess prevalence and contributing factors of SBS in Gondar town.

Methods

Study design and description of study settings

A community-based cross-sectional study was conducted from March to April 2017 in Gondar town. Gondar town is located in the northern part of Ethiopia in Amhara National Regional State, North Gondar Zone, at a distance of 747 km from Addis Ababa and 170 km from Bahirdar at 12° 45′ north latitude and 37° 45′ east longitudes. Gondar was founded in 1643. Based on the 2016 population estimate, Gondar had a total population of 621,168 with 3200/km2 [23].

Sample size determination

Single-population proportion formula [24] was used to determine the sample size (n) with the following assumptions: p (prevalence of SBS = 50%, hence there are no other similar studies in Ethiopia), 95% confidence interval (standard normal probability = 1.96); 3% margin of error or maximum error to commit, z = the standard normal tabulated value, and α = level of significance. We used a design effect of 3 based on the recommendation of the Population Services International research tool kit [25] and 7% non-response rate; the final sample became 3429.

Sampling procedures

Multistage sampling technique was used to select study participants. Seven kebeles (the lowest administrative unit in Ethiopia) were selected from a total of 22 kebeles using simple random sampling technique. Residential buildings found in the selected kebeles were chosen using systematic random sampling technique in every seven interval. The first residential building was selected from seven houses by lottery method.

Data collection procedures

A structured questionnaire and observational checklist were used to collect data. The questionnaire was pre-tested out of the study area in a community which had similar characteristics prior to the actual data collection. Twelve graduating class environmental health students were involved in the data collection process. Training was given for the data collectors and supervisors. The data collectors visited all systematically selected households and interviewed all household members. For under-5-year-old household members, data collectors interviewed mothers or caregivers. Data collectors asked the study subjects to recall the presence of 24 SBS symptoms and related information in 3 months prior to the survey. Collectors also observed the housing and living environment condition. The overall interview process was supervised by supervisors. The collected data were checked and corrected by the data collectors immediately after finalizing the questionnaire before they left the house. Supervisors daily checked the completeness, quality, and consistency of information collected.

Measurement of study variables

SBS, the primary outcome variable of this study, was defined as the presence of at least one symptom associated with housing condition in the last 3 months prior to the survey. SBS was assessed by asking have you had any (or more) of the following symptoms during the last 3 months: (i) general symptoms including fatigue, headache, dizziness, reduced attention, hyperactivity, fever, chills, and eye strain; (ii) mucosal symptoms including rhinitis, nasal congestion, wheezing, asthma, dyspnea, severe lung disease, epistaxis, upper respiratory tract irritation, chest tightness, dry throat, cough, and eye irritation; and (iii) skin symptoms including skin rashes, dry or flushed facial skin, scaling/itching scalp or ears, and lip dryness [9, 26, 27]. Five criteria were used to confirm whether the symptoms are SBS or not. The criteria were as follows: (a) symptoms aggravate when staying at home, (b) symptoms either immediately or gradually disappear when leaving the house, (c) symptoms recur when returning home, (d) symptoms aggravate during the night, and (e) symptoms disappear when the room is ventilated or cleaned. The wealth index of households was determined using principal component analysis (PCA). As health and demographic surveys (DHS) recommended, we used asset and service variables to determine the wealth index. Initially, the wealth index was classified into very poor, poor, moderate, rich, and very rich. But there was no significant difference between very poor and poor, and moderate, rich, and very rich. Based on this fact, the wealth index was classified into poor and rich. Residential buildings were taken as clean if the physical structures (floors, walls, ceilings, or roofs) have no any visible dirt, soot, spider’s wrap, crack, and dampness. The living compound was taken as clean if the living environment is free from wastes, vectors, and unpleasant odor. The illumination system of the living quarters was taken as adequate if the light energy is constant, free from glare, uniformly distributed to the entire room, and suitable to perform daily activities inside without strain.

Data management and statistical analysis

Data were entered using EPI-INFO version 7 and exported into SPSS version 20 for further analysis. For most variables, data were presented by frequencies and percentages. Univariable binary logistic regression analysis was used to choose variables for the multivariable binary logistic regression analysis, variables with p value less than 0.05 by the univariable analysis were then analyzed by multivariable binary logistic regression for controlling the possible effect of confounders (like age, sex, family size, economic status, and education status of the family), and finally, variables which had significant association with SBS were identified on the basis of AOR with 95% CI and p < 0.05. The Hosmer and Lemeshow goodness of fit test was used to check model fitness. VIF was also used to test interactions between variables.

Results

Socio-demographic information

A total of 964 residential buildings were visited, and a total of 3405 residents in these houses were included in this study with 99.4% response rate. One thousand eight hundred thirty-eight (54%) study subjects were female. Three fourth, 2620 (76.9%), of the study subjects were aged between 15 and 64 years. Nine hundred thirty-two (27.4%) participants graduated from colleges or universities. One thousand three hundred ninety-one (40.9%) study subjects were not engaged at the time of the survey, and 1179 (34.6%) participants were self-employed. Two thousand twenty-three (59.4%) study subjects were economically poor (Table 1).
Table 1

Socio-demographic information of study participants in Gondar town, northwest Ethiopia, March–April 2017

Socio-demographic variablesFrequencyPercentage
Sex
 Male156746.0
 Female183854.0
Age
 < 15 years64418.9
 15–64 years262076.9
 > 64 years1414.1
Educational status
 Underage1715.0
 Kindergarten1233.6
 Cannot read and write2387.0
 Can read and write43912.9
 Primary education58917.3
 Secondary education91326.8
 College or university93227.4
Marital status
 Underage62918.5
 Currently engaged138540.7
 Currently not engaged139140.9
Occupational status
 Underage822.4
 Student107231.5
 Unemployed2206.5
 Civil servant60917.9
 Self employed117934.6
 Retired2437.1
Economic status
 Poor202359.4
 Rich138240.6
Socio-demographic information of study participants in Gondar town, northwest Ethiopia, March–April 2017

Housing condition

The majority, 2389 (70.2%), of the study subjects lived in houses constructed from wood and mud. One thousand seven hundred eighty (52.3%) study subjects reported that the floor of their house is earthen floor. Two thousand eighty-six (61.3%) study subjects said that they had only one bedroom. The majority, 3217 (94.5%), of the study participants reported that they had no fan in their house. Nearly two thirds, 2211 (64.9%), of the study subjects said that their residential building has no functional windows. One thousand seven hundred sixty-six (51.9%) study subjects lived in houses in which the illumination system was not adequate. Almost all, 3317 (97.4%), of the study participants reported that they got light from electricity. A quarter, 879 (25.8%), of the study participants had pets in the home. Fungal growth and dampness was observed among 1462 (42.9%) participants’ house. One thousand three hundred seventy-six (40.4%) study subjects reported that they recently used pesticides, paints, and solvents. One thousand eight hundred eighty-five (55.4%) participants reported that cooking inside the living quarters is a common practice. One thousand three hundred twenty-seven (39%) study subjects said that outdoor air pollutant sources (like garages, and metal and woodwork houses) were found around their home (within a 200-m radius). Incensing and utilization of a joss stick was a common habit in 1329 (39%) participants’ house. Nearly one tenth, 335 (9.8%), of the study subjects reported that at least one of the family members smokes cigarette. The houses of 1196 (35.1%) study subjects were newly constructed (within 10 years), and the houses of 1295 (38%) subjects were clean (Table 2).
Table 2

Housing condition of study participants in Gondar town, northwest Ethiopia, March–April 2017

Housing- and sanitation-related variablesFrequencyPercentage
Wall constructed from
 Brick or block101629.8
 Wood and mud238970.2
Types of floor materials
 Earth floor178052.3
 Wood floor34710.2
 Ceramic/tiles/brick floor1915.6
 Cement floor108731.9
Number of bedrooms
 No separate bedroom54516.0
 1208661.3
 253115.6
 32437.1
Fan is available in the quarters
 Yes1885.5
 No321794.5
Functional windows
 No221164.9
 Yes119435.1
Illumination system of the building
 Adequate163948.1
 Not adequate176651.9
Light sources
 Electricity331797.4
 Solar cell792.3
 Candle or kuraz90.3
Pets in the home
 Yes87925.8
 No252674.2
Fungal growth is observed in the building
 Yes146242.9
 No194357.1
Pesticides, paints, and solvents used recently
 Yes137640.4
 No202959.6
Cooking inside
 Yes188555.4
 No152044.6
Outdoor air pollutant sources within a 200-m radius
 Yes132739.0
 No207861.0
Incensing habit and joss stick use
 Yes132939.0
 No207661.0
Cigarette smoking
 Yes3359.8
 No307090.2
Building age
 New119635.1
 Old220964.9
Cleanliness of the building
 Clean129538.0
 Not clean211062.0
Housing condition of study participants in Gondar town, northwest Ethiopia, March–April 2017

Sanitation of the living environment

Nearly two thirds, 2192 (64.4%), of the study participants used traditional pit latrine, and three fourths, 2600 (76.4%), of study subjects got drinking water from an in-compound tap. Three thousand sixteen (88.6%), 43 (1.3%), and 1892 (55.6%) of the study participants reported that they use charcoal, kerosene, and electricity, respectively, as household energy sources. A quarter, 887 (26%), of the participants reported vector infestation in their living environment, and the living environment of 2255 (66.2%) study subjects was clean (Table 3).
Table 3

Sanitation practices of study participants in Gondar town, northwest Ethiopia, March–April 2017

Sanitation-related variablesFrequencyPercentage
Toilet or latrine facilities
 Flush toilet94827.8
 Traditional pit latrine219264.4
 Ventilated improved pit latrine631.9
 No sanitation facility2025.9
Drinking water sources
 In-residence tap58917.3
 In-compound tap260076.4
 Out-of-compound tap2166.3
Use charcoal as energy source
 Yes301688.6
 No38911.4
Use kerosene as energy source
 Yes431.3
 No336298.7
Use electricity as energy source
 Yes189255.6
 No151344.4
Infestation of vectors
 Yes88726.0
 No251874.0
Cleanliness of living compound
 Clean225566.2
 Not clean115033.8
Sanitation practices of study participants in Gondar town, northwest Ethiopia, March–April 2017

Prevalence of sick building syndromes

From a total of 3405 participants included in this study, 738 participants reported one or more symptoms associated with poor housing condition. The prevalence of SBS in Gondar town was therefore found to be 21.7% (95% CI = 20.3–23.0%). Ninety (12.2%) occupants who had one or more symptoms reported that the symptoms always occurred, and 648(87.8%) occupants who had SBS said that the symptoms occurred sometimes in the last 3 months. From study participants who reported symptoms related with housing, 414 (56%) and 324 (44%) had one and more than one symptom/s, respectively. Four hundred seventy-four (64%), 401 (54%), and 72 (10%) of the reported symptoms were mucosal, general, and skin symptoms, respectively. Headache, 221 (15.7%); asthma, 116 (8.3%); rhinitis, 112 (8.0%); and dizziness, 106 (7.5%), were the commonest reported symptoms (Table 4).
Table 4

Symptoms related with housing as reported by study participants in Gondar town, northwest Ethiopia, March–April 2017

SymptomsFrequencyPercentage
General symptoms
 Headache22115.7
 Dizziness1067.5
 Fatigue976.9
 Fever795.6
 Chills362.6
 Hyperactivity342.4
 Reduced attention161.1
 Eye strain251.8
Mucosal symptoms
 Rhinitis1128.0
 Nasal congestion926.6
 Wheezing553.9
 Asthma1168.3
 Dyspnea181.3
 Severe lung disease201.4
 Epistaxis916.5
 Upper respiratory tract irritation100.7
 Chest tightness151.1
 Dry throat423.0
 Cough604.3
 Eye irritation694.9
Skin symptoms
 Skin rashes231.6
 Dry or flushed facial skin171.2
 Scaling/ itching scalp or ears171.2
 Lip dryness332.4
Symptoms related with housing as reported by study participants in Gondar town, northwest Ethiopia, March–April 2017

Factors associated with sick building syndromes

Univariable binary logistic regression was used to choose variables for the final model on the basis of p values less than 0.05. Types of wall; fungal growth; cleanliness of the building; presence of functional windows; presence of fan in the quarters; cooking inside the quarters; charcoal use; habits of cigarette smoking; incensing habit and joss stick use; outdoor pollutant sources near the building; recent utilization of pesticides, paints, and solvents; and cleanliness of the living compound were variables selected for the final model. VIF was calculated considering one independent variable as the dependent variable turn by turn to test interactions between variables. The test result shows that VIF for all variables was below 3, threshold for collinearity diagnostics. This showed that there is no multicollinearity effect between independent variables. Table 5 shows variables associated with SBS. SBS was statistically associated with fungal growth in the building. The probability of having SBS was 1.25 times higher among participants where fungal growth was observed in the building [AOR = 1.25, 95% CI = (1.05, 1.49)]. This study depicted that cleanliness of buildings was significantly associated with SBS. The odds of SBS was 1.26 times higher among occupants whose building is not clean compared with their counterparts [AOR = 1.26, 95% CI = (1.03, 1.55)]. The prevalence of SBS was 1.35 times higher among participants who lived in houses with no functional windows [AOR = 1.35, 95% CI = (1.12, 1.63)]. As revealed by this study, SBS was associated with utilization of fan. The probability of developing SBS was 1.90 times higher among study subjects who did not use fan [AOR = 1.90, 95% CI = (1.22, 2.96)]. This community-based study explored that SBS was associated with household cooking energy, cooking practice, and incensing habits of occupants. The odds of SBS was 1.4 times higher among occupants who used charcoal as cooking energy source [AOR = 1.40, 95% CI = (1.02, 1.91)]. Occupants who cooked inside the living quarters had more chance to develop SBS [AOR = 1.31, 95% CI = (1.09, 1.58)]. The probability to have SBS was 1.48 times higher among occupants who had a habit of incensing and using a joss stick [AOR = 1.48, 95% CI = (1.23, 1.77)].
Table 5

Factors associated with sick building syndromes among the population of Gondar town, northwest Ethiopia, March–April 2017

VariablesSBSCOR with 95% CIAOR with 95% CI
YesNo
Wall constructed from
 Brick or block1968201
 Wood and mud54218471.23(1.02, 1.47)1.10(0.89, 1.36)
Fungal growth is observed in the building
 Yes36211001.37(1.16, 1.62)1.25(1.05, 1.49)*
 No37615671
Cleanliness of the building
 Clean22410711
 Not clean51415961.54(1.29, 1.83)1.26(1.03, 1.55)*
Functional windows
 Yes51017011
 No2289661.27(1.07, 1.51)1.35(1.12, 1.63)**
Availability of fan in the quarters
 Yes271611
 No71125061.69(1.12, 2.57)1.90(1.22, 2.96)**
Charcoal use
 Yes68423321.82(1.35, 2.46)1.40(1.02, 1.91)*
 No543351
Cooking inside
 Yes47814071.65(1.39, 1.95)1.31(1.09, 1.58)**
 No26012601
Family members smoke cigarette
 Yes882471.33(1.03, 1.72)1.24(0.94, 1.63)
 No65024201
Incensing habit and joss stick use
 Yes3689611.77(1.50, 2.08)1.48(1.23, 1.77)***
 No37017061
Pollutant sources within the near distance
 Yes31210151.19(1.01, 1.41)0.99(0.82, 1.18)
 No42616521
Pesticides, paints, and solvents used recently
 Yes32910471.25(1.06, 1.47)1.14(0.95, 1.37)
 No40916201
Cleanliness of the compound
 Clean44418111
 Not clean2948561.40(1.18, 1.66)1.16(0.96, 1.40)

Hosmer and Lemeshow test = 0.154 showed that the model fitted well

*Statistically significant at p < 0.05

**Statistically significant at p < 0.01

***Statistically significant at p < 0.001

Factors associated with sick building syndromes among the population of Gondar town, northwest Ethiopia, March–April 2017 Hosmer and Lemeshow test = 0.154 showed that the model fitted well *Statistically significant at p < 0.05 **Statistically significant at p < 0.01 ***Statistically significant at p < 0.001

Discussion

This study found that prevalence of SBS was 21.7% (64% mucosal symptoms, 54% general symptoms, and 10% skin symptoms). The prevalence of mucosal, general, and skin symptoms reported by this study is higher than the findings of other studies in China which reported mucosal symptoms (7.1%), general symptoms (11.4%), and skin symptoms (4.4%) [27]. Another study in China reported lower prevalence (mucosal symptoms (35.1%), general symptoms (39.4%,) and skin symptoms (43.4%)) [9] compared to the current study with exception of skin symptoms. The current prevalence is lower than that report in a study in three North European cities. The prevalence reported by the later study was 30.8% (20% mucosal, 10% general, and 8% dermal symptoms) [28]. The finding of the current study is also lower than that of a study in China that reported 74.3% mucosal symptoms, 78.7% general symptoms, and 47.5% skin symptoms [29]. The variations of prevalence among different studies may be due to differences in housing and environmental conditions. Most of the houses in the current study area were substandard. The outdoor air in the settings of the other studies is polluted by industrial emissions compared with the current setting. This study depicted that cleanliness of residential buildings was statistically associated with SBS. The prevalence of SBS was higher among occupants who lived in unclean buildings compared with occupants who lived in clean buildings. This finding is in line with the findings of other similar studies [7, 9, 19, 30]. This may be due to the fact that unclean building surfaces including carpets accumulate dust and dirt, which are reservoirs for chemicals, allergens, and diseases causing pathogens [31, 32]. SBS was significantly associated with infestation of fungus or molds in the living building. Occupants who lived in buildings where fungal growth was observed reported SBS compared with their counterparts. The finding of this study is supported by other studies [7, 16, 33]. This is due to the fact that fungus or molds cause health problems in the mechanisms of either infection or allergy or toxin. Fungal spores are generally recognized as important causes of respiratory allergies [16, 34]. The current study explored that availability of functional windows is statistically associated with SBS. A wide range of literature also reported the effect of general ventilation on the health of the occupants [19, 35–37]. This fact can be explained that presence of functional windows as means of ventilating a building naturally helps the external fresh air to the living quarters and removes the internal exhausted air which in turn reduces the amount of contamination with chemicals or microorganisms, so that increased ventilation can be seen as an effective treatment of SBS [19, 37–39]. This study also revealed that availability of fan in the living quarters was significantly associated with SBS. The prevalence of SBS was higher among occupants who lived in houses with no fan. Other studies also reported similar findings [40, 41]. This is because fan-assisted ventilation improves the quality of the indoor air [42, 43]. This study reported that SBS was associated with household cooking energy sources, cooking practice, and incensing habits of occupants. The prevalence of SBS was higher among occupants who used charcoal as cooking energy source. Occupants who used charcoal and cooked inside the living quarters [44-46] and who used incensing and joss stick [27, 29] had more chance to develop SBS. This can be justified that charcoal use and incensing habits are incomplete combustion processes that can generate gracious pollutants. Generally, cooking energy sources and cooking practices are the main sources for gracious pollutants to the indoor air [47, 48].

Limitation of the study

This research did not assess the condition of office buildings in this study though the condition of office buildings is a covariate for SBS associated with residential buildings. Moreover, we did not measure indoor air quality, thermal condition, and light intensity using instruments. However, we used standardized checklists to assess these parameters.

Conclusion

The prevalence of SBS in Gondar town was found to be high, and a significant proportion of the population had more than one SBS symptom. Headache, asthma, rhinitis, and dizziness were the commonest reported SBS symptoms. Fungal growth, cleanliness of the building, availability of functional windows, availability of fan in the living quarters, using charcoal as cooking energy source, cooking inside the quarters, and incensing habits or joss stick use were identified as factors associated with SBS. Improving the sanitation of the living environment and housekeeping practice of the occupants is useful to minimize the prevalence of SBS.
  23 in total

Review 1.  Housing and health: time again for public health action.

Authors:  James Krieger; Donna L Higgins
Journal:  Am J Public Health       Date:  2002-05       Impact factor: 9.308

Review 2.  Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to "dampness" in buildings and health effects (NORDDAMP).

Authors:  C G Bornehag; G Blomquist; F Gyntelberg; B Järvholm; P Malmberg; L Nordvall; A Nielsen; G Pershagen; J Sundell
Journal:  Indoor Air       Date:  2001-06       Impact factor: 5.770

3.  Indoor particles and symptoms among office workers: results from a double-blind cross-over study.

Authors:  Mark J Mendell; William J Fisk; Marty R Petersen; Cynthia J Hines; Maxia Dong; David Faulkner; James A Deddens; Avima M Ruder; Douglas Sullivan; Mark F Boeniger
Journal:  Epidemiology       Date:  2002-05       Impact factor: 4.822

Review 4.  Sick building syndrome.

Authors:  P S Burge
Journal:  Occup Environ Med       Date:  2004-02       Impact factor: 4.402

5.  Airborne molds and bacteria, microbial volatile organic compounds (MVOC), plasticizers and formaldehyde in dwellings in three North European cities in relation to sick building syndrome (SBS).

Authors:  Bo Sahlberg; Maria Gunnbjörnsdottir; Argo Soon; Rain Jogi; Thorarinn Gislason; Gunilla Wieslander; Christer Janson; Dan Norback
Journal:  Sci Total Environ       Date:  2012-12-29       Impact factor: 7.963

6.  Indoor and outdoor particulate matter in primary school classrooms with fan-assisted natural ventilation in Singapore.

Authors:  Ailu Chen; Elliott T Gall; Victor W C Chang
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-28       Impact factor: 4.223

Review 7.  Molds, mycotoxins, and sick building syndrome.

Authors:  David C Straus
Journal:  Toxicol Ind Health       Date:  2009 Oct-Nov       Impact factor: 2.273

Review 8.  Toxic mold: phantom risk vs science.

Authors:  Jean A Chapman; Abba I Terr; Robert L Jacobs; Ernest N Charlesworth; Emil J Bardana
Journal:  Ann Allergy Asthma Immunol       Date:  2003-09       Impact factor: 6.347

Review 9.  Sick Building Syndrome: is mould the cause?

Authors:  Abba I Terr
Journal:  Med Mycol       Date:  2009-03-02       Impact factor: 4.076

10.  Effect of Traffic Exposure on Sick Building Syndrome Symptoms among Parents/Grandparents of Preschool Children in Beijing, China.

Authors:  Linyan Li; Gary Adamkiewicz; Yinping Zhang; John D Spengler; Fang Qu; Jan Sundell
Journal:  PLoS One       Date:  2015-06-18       Impact factor: 3.240

View more
  6 in total

1.  Working Conditions and Sick Building Syndrome among Health Care Workers in Vietnam.

Authors:  Cuong Hoang Quoc; Giang Vu Huong; Hai Nguyen Duc
Journal:  Int J Environ Res Public Health       Date:  2020-05-21       Impact factor: 3.390

2.  Analysis of Larch-Bark Capacity for Formaldehyde Removal in Wood Adhesives.

Authors:  Eugenia Mariana Tudor; Marius Catalin Barbu; Alexander Petutschnigg; Roman Réh; Ľuboš Krišťák
Journal:  Int J Environ Res Public Health       Date:  2020-01-25       Impact factor: 3.390

3.  Prevalence and risk factors of pre-sick building syndrome: characteristics of indoor environmental and individual factors.

Authors:  Yoshitake Nakayama; Hiroko Nakaoka; Norimichi Suzuki; Kayo Tsumura; Masamichi Hanazato; Emiko Todaka; Chisato Mori
Journal:  Environ Health Prev Med       Date:  2019-12-17       Impact factor: 3.674

4.  Knowledge, Attitudes, Practices, and Determinants Towards Wastewater Management in Northwest Ethiopia: A Community-Based Cross-Sectional Study.

Authors:  Gebisa Kabito; Henok Dagne; Mulat G/Hiwot
Journal:  Risk Manag Healthc Policy       Date:  2021-06-24

5.  Exposure to Wood Smoke and Associated Health Effects in Sub-Saharan Africa: A Systematic Review.

Authors:  Onyinyechi Bede-Ojimadu; Orish Ebere Orisakwe
Journal:  Ann Glob Health       Date:  2020-03-20       Impact factor: 2.462

6.  Community's perceived high risk of coronavirus infections during early phase of epidemics are significantly influenced by socio-demographic background, in Gondar City, Northwest Ethiopia: A cross-sectional -study.

Authors:  Gebisa Guyasa Kabito; Mekuriaw Alemayehu; Tesfaye Hambisa Mekonnen; Sintayehu Daba Wami; Jember Azanaw; Tsegaye Adane; Zelalem Nigussie Azene; Mehari Woldemariam Merid; Atalay Goshu Muluneh; Demiss Mulatu Geberu; Getahun Molla Kassa; Melaku Kindie Yenit; Sewbesew Yitayih Tilahun; Kassahun Alemu Gelaye; Habtamu Sewunet Mekonnen; Abere Woretaw Azagew; Chalachew Adugna Wubneh; Getaneh Mulualem Belay; Nega Tezera Assimamaw; Chilot Desta Agegnehu; Telake Azale; Animut Tagele Tamiru; Bayew Kelkay Rade; Eden Bishaw Taye; Asefa Adimasu Taddese; Zewudu Andualem; Henok Dagne; Kiros Terefe Gashaye
Journal:  PLoS One       Date:  2020-11-19       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.