Literature DB >> 30367232

[Precision pulse capsulotomy : The new capsulorhexis?]

M D Becker1, S Michels2, S Lortz2, S Kaminski2.   

Abstract

The manual capsulorhexis created by Neuhann is still the standard procedure for opening the anterior capsule for cataract surgery. A limitation is the inaccuracy in the size and placement of the opening due to manual execution. In addition to the femtosecond laser a possible improvement in the standardization of capsulorhexis is provided by the Zepto procedure (precision pulse capsulotomy, PPC). In this case a 5.25 mm rhexis is created in a standardized fashion with a flexible suction adapter in which a nitinol ring is located. Whether the strength of PPC is comparable or better than that of the manual technique and how it behaves in terms of capsule shrinkage has not yet been finally clarified.

Entities:  

Keywords:  Capsule shrinkage; Cataract surgery; Nitinol; Rhexis; Standardization

Mesh:

Year:  2019        PMID: 30367232     DOI: 10.1007/s00347-018-0807-9

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  8 in total

1.  Continuous curvilinear capsulorhexis.

Authors:  H V Gimbel; T Neuhann
Journal:  J Cataract Refract Surg       Date:  1991-01       Impact factor: 3.351

2.  [Theory and surgical technic of capsulorhexis].

Authors:  T Neuhann
Journal:  Klin Monbl Augenheilkd       Date:  1987-06       Impact factor: 0.700

3.  Thermal capsulotomy: Initial clinical experience, intraoperative performance, safety, and early postoperative outcomes of precision pulse capsulotomy technology.

Authors:  Joobin Hooshmand; Robin G Abell; Penny Allen; Brendan J Vote
Journal:  J Cataract Refract Surg       Date:  2018-03       Impact factor: 3.351

4.  Intereye comparison of femtosecond laser-assisted cataract surgery capsulotomy and manual capsulorhexis edge strength.

Authors:  Thomas Chan; Ushasree Pattamatta; Mark Butlin; Kerrie Meades; Chandra Bala
Journal:  J Cataract Refract Surg       Date:  2017-04       Impact factor: 3.351

5.  Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.

Authors:  David F Chang; Nick Mamalis; Liliana Werner
Journal:  Ophthalmology       Date:  2015-11-12       Impact factor: 12.079

6.  Comparison of Manual, Femtosecond Laser, and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver Eyes.

Authors:  Vance M Thompson; John P Berdahl; Joel M Solano; David F Chang
Journal:  Ophthalmology       Date:  2015-12-23       Impact factor: 12.079

7.  Anterior capsulotomy integrity after femtosecond laser-assisted cataract surgery.

Authors:  Robin G Abell; Peter E J Davies; David Phelan; Karsten Goemann; Zachary E McPherson; Brendan J Vote
Journal:  Ophthalmology       Date:  2013-09-29       Impact factor: 12.079

8.  Precision pulse capsulotomy in phacoemulsification: Clinical experience in Indian eyes.

Authors:  Jai A Kelkar; Hetal M Mehta; Aditya S Kelkar; Aanchal A Agarwal; Akshay A Kothari; Shreekant B Kelkar
Journal:  Indian J Ophthalmol       Date:  2018-09       Impact factor: 1.848

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.