Literature DB >> 30358113

Accurate and sensitive determination of sildenafil, tadalafil, vardenafil, and avanafil in illicit erectile dysfunction medications and human urine by LC with quadrupole-TOF-MS/MS and their behaviors in simulated gastric conditions.

Elif Öztürk Er1, Belma Özbek1, Sezgin Bakırdere2.   

Abstract

The widespread use of phosphodiesterase-5 inhibitors has attracted broad attention of counterfeiters to develop illicit erectile products with inaccurate amounts, unknown toxicity, and purity of active ingredients. Correspondingly, intake of these products endangers consumer health and needs to be screened for precautionary actions to reduce this risk. Therefore, in this study, a sensitive and rapid analytical method has been developed for simultaneous determination of selected phosphodiesterase-5 inhibitors present in illicit erectile medications and human urine. Quantification of the analytes was performed by liquid chromatography coupled with quadrupole-time-of-flight tandem mass spectrometry system. The chromatographic separation was successfully achieved with a run period of 8 min. Low detection limits were obtained in the range of 1.63-9.81 ng/g with relative standard deviations below 7.72% obtained using the replicate measurements of lowest concentration in calibration plots. The analytical performance of the proposed method proved good linearity, low detection limits, good accuracy and precision with high percent recoveries for human urine samples. Developed method was successfully applied to real samples including four different brands of illicit erectile medications. The results obtained revealed the presence of high levels of sildenafil in analyzed samples. The behaviors of selected phosphodiesterase-5 inhibitors were also studied in simulated gastric conditions.
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  erectile dysfunction; gastric conditions; human urine; illicit erectile medication; phosphodiesterase-5 inhibitors

Mesh:

Substances:

Year:  2018        PMID: 30358113     DOI: 10.1002/jssc.201800734

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  6 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

Review 2.  Sildenafil 4.0-Integrated Synthetic Chemistry, Formulation and Analytical Strategies Effecting Immense Therapeutic and Societal Impact in the Fourth Industrial Era.

Authors:  Andreas Ouranidis; Anastasia Tsiaxerli; Elisavet Vardaka; Catherine K Markopoulou; Constantinos K Zacharis; Ioannis Nicolaou; Dimitris Hatzichristou; Anna-Bettina Haidich; Nikolaos Kostomitsopoulos; Kyriakos Kachrimanis
Journal:  Pharmaceuticals (Basel)       Date:  2021-04-15

3.  Second derivative synchronous fluorescence determination of avanafil in the presence of its acid-induced degradation product aided by powerful Lean Six Sigma tools augmented with D-optimal design.

Authors:  Khalid A M Attia; Ahmad A Mohamad; Mohamed S Emara; Ahmed M Abdel-Raoof; Mohamed A Hasan; Ahmed W Madkour; Ebrahim A El-Desouky
Journal:  RSC Adv       Date:  2021-01-19       Impact factor: 3.361

Review 4.  Facing Counterfeit Medications in Sexual Medicine. A Systematic Scoping Review on Social Strategies and Technological Solutions.

Authors:  Andrea Sansone; Béatrice Cuzin; Emmanuele A Jannini
Journal:  Sex Med       Date:  2021-10-04       Impact factor: 2.491

5.  HPLC-UV and UPLC-MS/MS methods for the simultaneous analysis of sildenafil, vardenafil, and tadalafil and their counterfeits dapoxetine, paroxetine, citalopram, tramadol, and yohimbine in aphrodisiac products.

Authors:  Mohamed A Abdelshakour; Randa A Abdel Salam; Ghada M Hadad; Dina M Abo-ElMatty; Eman A Abdel Hameed
Journal:  RSC Adv       Date:  2021-02-18       Impact factor: 3.361

6.  Simultaneous determination of Avanafil and Dapoxetine in human plasma using liquid chromatography/tandem mass spectrometry (LC-MS/MS) based on a protein precipitation technique.

Authors:  Mona N Abou-Omar; Abdelaziz M Annadi; Noha M El Zahar; Ahmed O Youssef; Mohammed A Amin; Mohamed S Attia; Ekram H Mohamed
Journal:  RSC Adv       Date:  2021-09-06       Impact factor: 4.036

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.