Literature DB >> 30353647

Interlaboratory comparison of the TransFix®/EDTA Vacuum Blood Collection tube with the 5 mL Cyto-Chex® BCT.

Daniel Harrison1, Rosalie Ward2, Sarah Bastow3, Andrew Parr3, Susan Macro4, Paul K Wallace4.   

Abstract

BACKGROUND: An interlaboratory study was performed to compare the performance of the 3 mL TransFix®/EDTA Vacuum Blood Collection Tube (TVT), with the 5 mL Cyto-Chex® BCT tube (BCT). Both devices are intended for collection and storage of whole blood specimens for immunophenotyping of leukocytes by flow cytometry for up to 14 days.
METHODS: One site in the United States and two in the United Kingdom tested samples from 10 HIV positive patients and four healthy subjects for a total of 42 samples. From each subject, three blood samples were collected: a BD 4 mL K3 EDTA Vacutainer (Vacutainer), a TVT, and a BCT. At all sites, samples were analyzed on a BD FACS Canto II flow cytometer for a full lymphocyte subset count within 6 h of collection (all devices) and on Day 11 and Day 15 (TVT and BCT only). Data obtained from the Vacutainer were used as the control data set with which TVT and BCT data were statistically compared. RESULTS AND
CONCLUSIONS: Statistical concordance was demonstrated for both devices in relation to cell absolute count recovery. For cell marker signal, both devices exhibited a significant decrease in mean fluorescence intensity (MFI) for the detection of lymphocyte subsets and their target markers. There was a marked increase in autofluorescence observed for BCT stabilized lymphocytes whereas values for the TVTs were comparable to the control. There were eight instances of statistical equivalence between the level of antibody autofluorescence observed in the control tube and the TVT across both patient cohorts, versus two for the BCT.
© 2018 International Clinical Cytometry Society. © 2018 International Clinical Cytometry Society.

Entities:  

Keywords:  HIV; hematology; immunophenotyping

Mesh:

Substances:

Year:  2018        PMID: 30353647      PMCID: PMC7341537          DOI: 10.1002/cyto.b.21731

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.248


  13 in total

1.  Affordable CD4+ T cell counts by flow cytometry. II. The use of fixed whole blood in resource-poor settings.

Authors:  V Jani; G Janossy; A Iqbal; F S Mhalu; E F Lyamuya; G Biberfeld; D K Glencross; L Scott; J T Reilly; V Granger; D Barnett
Journal:  J Immunol Methods       Date:  2001-11-01       Impact factor: 2.303

2.  Efficacy of Cyto-Chex blood preservative for delayed manual CD4 testing using Dynal T4 Quant CD4 test among HIV-infected persons in Zambia.

Authors:  April A Truett; Andrew Letizia; Evans Malyangu; Frank Sinyangwe; Brandi N Morales; Nancy F Crum; Suzanne M Crowe
Journal:  J Acquir Immune Defic Syndr       Date:  2006-02-01       Impact factor: 3.731

3.  Stabilization of white blood cells and immunologic markers for extended analysis using flow cytometry.

Authors:  Dominic E Warrino; Louis J DeGennaro; Mary Hanson; Susan Swindells; Samuel J Pirruccello; Wayne L Ryan
Journal:  J Immunol Methods       Date:  2005-10-30       Impact factor: 2.303

4.  Research needs and challenges in the development of HIV diagnostic and treatment monitoring tests for use in resource-limited settings.

Authors:  Ben Cheng; Alan Landay; Veronica Miller
Journal:  Curr Opin HIV AIDS       Date:  2008-07       Impact factor: 4.283

5.  Flow cytometric profiles, biomolecular and morphological aspects of transfixed leukocytes and red cells.

Authors:  Barbara Canonico; Michele Betti; Francesca Luchetti; Michela Battistelli; Elisabetta Falcieri; Paola Ferri; Loris Zamai; David Barnett; Stefano Papa
Journal:  Cytometry B Clin Cytom       Date:  2010-07       Impact factor: 3.058

Review 6.  Implementation of highly sophisticated flow cytometry assays in multicenter clinical studies: considerations and guidance.

Authors:  Ulrike Sommer; Johanna Morales; Andrea Groenewegen; Annemarie Müller; Julia Naab; Gaetane Woerly; Esther Kamphausen; Helene Marsot; Patrick Bennett; Vellalore Kakkanaiah; Alessandra Vitaliti
Journal:  Bioanalysis       Date:  2015       Impact factor: 2.681

Review 7.  Flow cytometry: a flexible tool for biomarker research.

Authors:  Ruth M Barnard
Journal:  Bioanalysis       Date:  2012-10       Impact factor: 2.681

8.  First-in-Human Study in Healthy Subjects with FR104, a Pegylated Monoclonal Antibody Fragment Antagonist of CD28.

Authors:  Nicolas Poirier; Gilles Blancho; Maryvonne Hiance; Caroline Mary; Tim Van Assche; Jos Lempoels; Steven Ramael; Weirong Wang; Virginie Thepenier; Cecile Braudeau; Nina Salabert; Regis Josien; Ian Anderson; Ian Gourley; Jean-Paul Soulillou; Didier Coquoz; Bernard Vanhove
Journal:  J Immunol       Date:  2016-11-14       Impact factor: 5.422

9.  Guidelines for performing single-platform absolute CD4+ T-cell determinations with CD45 gating for persons infected with human immunodeficiency virus. Centers for Disease Control and Prevention.

Authors:  Francis F Mandy; Janet K A Nicholson; J Steven McDougal
Journal:  MMWR Recomm Rep       Date:  2003-01-31

10.  Diagnostic accuracy and clinical utility of a simplified low cost method of counting CD4 cells with flow cytometry in Malawi: diagnostic accuracy study.

Authors:  Calman A MacLennan; Michael K P Liu; Sarah A White; Joep J G van Oosterhout; Felanji Simukonda; Joseph Bwanali; Michael J Moore; Eduard E Zijlstra; Mark T Drayson; Malcolm E Molyneux
Journal:  BMJ       Date:  2007-07-17
View more
  3 in total

Review 1.  Circulating stem cells and cardiovascular outcomes: from basic science to the clinic.

Authors:  Gian Paolo Fadini; Anurag Mehta; Devinder Singh Dhindsa; Benedetta Maria Bonora; Gopalkrishna Sreejit; Prabhakara Nagareddy; Arshed Ali Quyyumi
Journal:  Eur Heart J       Date:  2020-11-21       Impact factor: 29.983

2.  Multicentre Harmonisation of a Six-Colour Flow Cytometry Panel for Naïve/Memory T Cell Immunomonitoring.

Authors:  Iole Macchia; Valentina La Sorsa; Irene Ruspantini; Massimo Sanchez; Valentina Tirelli; Maria Carollo; Giorgio Fedele; Pasqualina Leone; Giovanna Schiavoni; Carla Buccione; Paola Rizza; Paola Nisticò; Belinda Palermo; Stefania Morrone; Helena Stabile; Aurelia Rughetti; Marianna Nuti; Ilaria Grazia Zizzari; Cinzia Fionda; Roberta Maggio; Cristina Capuano; Concetta Quintarelli; Matilde Sinibaldi; Chiara Agrati; Rita Casetti; Andrea Rozo Gonzalez; Floriana Iacobone; Angela Gismondi; Filippo Belardelli; Mauro Biffoni; Francesca Urbani
Journal:  J Immunol Res       Date:  2020-04-12       Impact factor: 4.818

Review 3.  The influence of fixation of biological samples on cell count and marker expression stability in flow cytometric analyses.

Authors:  Łukasz SĘdek; Jan Kulis; Łukasz SŁota; Magdalena Twardoch; Magdalena Pierzyna-ŚwitaŁa; Bartosz Perkowski; Tomasz SzczepaŃski
Journal:  Cent Eur J Immunol       Date:  2020-06-08       Impact factor: 2.085

  3 in total