Literature DB >> 30346630

Influence of the keratinized mucosa on the stability of peri-implant tissues and brushing discomfort: A 4-year follow-up study.

Jeniffer Perussolo1, André B Souza2, Flávia Matarazzo1, Ricardo P Oliveira3, Mauricio G Araújo1.   

Abstract

OBJECTIVE: The purpose of the present prospective follow-up study was to evaluate the long-term influence of the peri-implant keratinized mucosa (KM) on marginal bone level (MBL), peri-implant tissues health, and brushing discomfort.
MATERIAL AND METHODS: Eighty patients were initially recruited during their maintenance visit from January to October 2013 and allocated in two groups according to KM width around implants: Wide Group (KM ≥ 2 mm) and Narrow Group (KM < 2 mm). In the four-year follow-up examination (T4), marginal bone level (MBL), modified plaque index (mPI), probing depth (PD), clinical attachment level (CAL), bleeding on probing (BoP), and brushing discomfort (BD) were reassessed and compared to the initial assessments (T0). Mann-Whitney, Wilcoxon signed-rank test, and a multilevel model were used for the statistical analysis.
RESULTS: Fifty-four patients with 202 implants returned at T4. Mean mPI (0.91 ± 0.60), BoP (0.67 ± 0.21), and BD (12.28 ± 17.59) were higher in the Narrow Group than in the Wide Group (0.54 ± 0.48, 0.56 ± 0.26, and 4.25 ± 8.39, respectively). Marginal bone loss was higher in the Narrow Group (0.26 ± 0.71) than in the Wide Group (0.06 ± 0.48). Multilevel analysis suggested that KM width and time in function had a statistically significant effect on MBL.
CONCLUSIONS: The findings of the present study indicate that KM width had an effect on MBL, plaque accumulation, tissue inflammation, and brushing discomfort over the studied period. Thus, the presence of a KM ≥ 2 mm around implants appears to have a protective effect on peri-implant tissues.
© 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  brushing discomfort; dental implants; inflammation; keratinized mucosa; marginal bone level

Mesh:

Substances:

Year:  2018        PMID: 30346630     DOI: 10.1111/clr.13381

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  10 in total

1.  Success of dental implants in patients with large bone defect and analysis of risk factors for implant failure: a non-randomized retrospective cohort study.

Authors:  Takumi Hasegawa; Aki Sasaki; Izumi Saito; Satomi Arimoto; Nanae Yatagai; Yujiro Hiraoka; Daisuke Takeda; Yasumasa Kakei; Masaya Akashi
Journal:  Clin Oral Investig       Date:  2021-11-16       Impact factor: 3.573

Review 2.  Use of Xenogenic Collagen Matrices in Peri-Implant Soft Tissue Volume Augmentation: A Critical Review on the Current Evidence and New Technique Presentation.

Authors:  Carlo De Annuntiis; Luca Testarelli; Renzo Guarnieri
Journal:  Materials (Basel)       Date:  2022-05-31       Impact factor: 3.748

3.  Ultrasonographic tissue perfusion analysis at implant and palatal donor sites following soft tissue augmentation: A clinical pilot study.

Authors:  Lorenzo Tavelli; Shayan Barootchi; Jad Majzoub; Hsun-Liang Chan; William V Giannobile; Hom-Lay Wang; Oliver D Kripfgans
Journal:  J Clin Periodontol       Date:  2021-02-03       Impact factor: 8.728

4.  Comprehensive peri-implant tissue evaluation with ultrasonography and cone-beam computed tomography: A pilot study.

Authors:  Rafael Siqueira; Khaled Sinjab; Ying-Chun Pan; Fabiana Soki; Hsun-Liang Chan; Oliver Kripfgans
Journal:  Clin Oral Implants Res       Date:  2021-05-03       Impact factor: 5.021

5.  Analysis of risk indicators for prevalence of peri-implant diseases in Turkish population.

Authors:  Sadiye Gunpinar; Bilge Meraci; Mert Karas
Journal:  Int J Implant Dent       Date:  2020-05-20

6.  Radiographic evaluation of a cross-shaped incision technique for thick-gingiva and thin-gingiva patients treated with implant-supported fixed prosthesis.

Authors:  Wen Luo; Xinyu Wang; Yaqian Chen; Yuping Hong; Yili Qu; Yi Man; Yingying Wu
Journal:  BMC Oral Health       Date:  2021-12-18       Impact factor: 2.757

Review 7.  Does the timing of implant placement and loading influence biological outcomes of implant-supported multiple-unit fixed dental prosthesis-A systematic review with meta-analyses.

Authors:  Louise Leite Aiquel; João Pitta; Georgios N Antonoglou; Irene Mischak; Irena Sailer; Michael Payer
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

8.  Soft tissue phenotype modification predicts gingival margin long-term (10-year) stability: Longitudinal analysis of six randomized clinical trials.

Authors:  Shayan Barootchi; Lorenzo Tavelli; Riccardo Di Gianfilippo; Kerby Shedden; Tae-Ju Oh; Giulio Rasperini; Rodrigo Neiva; William V Giannobile; Hom-Lay Wang
Journal:  J Clin Periodontol       Date:  2022-05-13       Impact factor: 7.478

Review 9.  The role of keratinized mucosa width as a risk factor for peri-implant disease: A systematic review, meta-analysis, and trial sequential analysis.

Authors:  Andrea Ravidà; Claudia Arena; Mustafa Tattan; Vito Carlo Alberto Caponio; Muhammad H A Saleh; Hom-Lay Wang; Giuseppe Troiano
Journal:  Clin Implant Dent Relat Res       Date:  2022-03-17       Impact factor: 4.259

Review 10.  Prevalence and risk indicators for peri-implant diseases: A literature review.

Authors:  Masahiro Wada; Tomoaki Mameno; Motohiro Otsuki; Misako Kani; Yoshitaka Tsujioka; Kazunori Ikebe
Journal:  Jpn Dent Sci Rev       Date:  2021-06-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.