PURPOSE: Assessment of intraoperative quantitative shear wave elastography (SWE) and contrast-enhanced ultrasound (CEUS) for the characterization of focal liver lesions (FLLs) during liver surgery using postoperative histopathological results as the gold standard. MATERIALS AND METHODS: US data of 79 consecutive patients with 98 FLLs who underwent liver surgery between 08/2015 - 06/2017 were prospectively acquired and retrospectively analyzed. Multifrequency linear/T-shaped probes (6 - 9 MHz) were used to store cine loops of at least 5 s and images of B-mode, SWE and CEUS. The first CEUS loop was continuously documented over 1 min. in each case. Quantitative SWE analysis of FLLs was performed by placing 5 regions of interest to measure shear wave speed (m/s) and stiffness (kPa). CEUS was evaluated during the arterial, portal venous and late phase after i. v. bolus injections of 2.4 - 10 ml sulfur hexafluoride microbubbles. Postoperative histopathology after tumor resection or intraoperative biopsy was obtained to confirm findings of SWE and CEUS. RESULTS: Of 98 FLLs in 79 patients (mean age: 58 years sd ± 12y) 88 were malignant and 10 were benign ranging from 0.69 to 15.2 cm in size (mean: 2.8 cm, sd ± 2.25 cm). SWE characterized 73/88 FLLs correctly as malignant and 7/10 as benign using a cut-off value of 2.5 m/s/21.3 kPa (p < 0.0005). The sensitivity was 83 %, specificity 70 %, accuracy 82 %. CEUS could correctly identify 86/88 malignant and 8/10 benign FLLs. The sensitivity was 98 %, specificity 80 %, accuracy 96 %. SWE could correctly identify 2 malignant FLLs which CEUS falsely characterized as benign. CONCLUSION: Intraoperative CEUS and SWE are excellent tools for the highly accurate visualization, characterization and malignancy assessment of hepatic tumors during liver surgery. © Georg Thieme Verlag KG Stuttgart · New York.
PURPOSE: Assessment of intraoperative quantitative shear wave elastography (SWE) and contrast-enhanced ultrasound (CEUS) for the characterization of focal liver lesions (FLLs) during liver surgery using postoperative histopathological results as the gold standard. MATERIALS AND METHODS: US data of 79 consecutive patients with 98 FLLs who underwent liver surgery between 08/2015 - 06/2017 were prospectively acquired and retrospectively analyzed. Multifrequency linear/T-shaped probes (6 - 9 MHz) were used to store cine loops of at least 5 s and images of B-mode, SWE and CEUS. The first CEUS loop was continuously documented over 1 min. in each case. Quantitative SWE analysis of FLLs was performed by placing 5 regions of interest to measure shear wave speed (m/s) and stiffness (kPa). CEUS was evaluated during the arterial, portal venous and late phase after i. v. bolus injections of 2.4 - 10 ml sulfur hexafluoride microbubbles. Postoperative histopathology after tumor resection or intraoperative biopsy was obtained to confirm findings of SWE and CEUS. RESULTS: Of 98 FLLs in 79 patients (mean age: 58 years sd ± 12y) 88 were malignant and 10 were benign ranging from 0.69 to 15.2 cm in size (mean: 2.8 cm, sd ± 2.25 cm). SWE characterized 73/88 FLLs correctly as malignant and 7/10 as benign using a cut-off value of 2.5 m/s/21.3 kPa (p < 0.0005). The sensitivity was 83 %, specificity 70 %, accuracy 82 %. CEUS could correctly identify 86/88 malignant and 8/10 benign FLLs. The sensitivity was 98 %, specificity 80 %, accuracy 96 %. SWE could correctly identify 2 malignant FLLs which CEUS falsely characterized as benign. CONCLUSION: Intraoperative CEUS and SWE are excellent tools for the highly accurate visualization, characterization and malignancy assessment of hepatic tumors during liver surgery. © Georg Thieme Verlag KG Stuttgart · New York.
Entities: Chemical
Disease
Species
Mesh: See more »
Substances: See more »
Year: 2018
PMID: 30340245 DOI: 10.1055/a-0649-1000
Source DB: PubMed Journal: Ultraschall Med ISSN: 0172-4614 Impact factor: 6.548