Literature DB >> 30334889

Multisite Evaluation of a Custom Energy-Storing Carbon Fiber Orthosis for Patients with Residual Disability After Lower-Limb Trauma.

Benjamin K Potter1, Robert G Sheu2, Daniel Stinner3, John Fergason3, Joseph R Hsu4, Kevin Kuhn2, Johnny G Owens3, Jessica Rivera3, Scott B Shawen1, Jason M Wilken3, Jennifer DeSanto5, Yanjie Huang5, Daniel O Scharfstein5, Ellen J MacKenzie5.   

Abstract

BACKGROUND: The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is a custom energy-storing carbon fiber ankle-foot orthosis developed for lower-extremity trauma patients. Studies conducted at the military treatment facility where the IDEO was developed demonstrated benefits of the IDEO when used with the Return to Run Physical Therapy (RTR PT) program. The current study was designed to determine if results could be replicated at other military treatment facilities and to examine whether early performance gains in patient-reported functional outcomes remained at 12 months.
METHODS: Study participants included service members who had functional deficits that interfered with daily activities at least 1 year after a traumatic unilateral lower-extremity injury at or below the knee. Participants were evaluated before receiving the IDEO, immediately following completion of RTR PT, and at 6 and 12 months. Agility, strength/power, and speed were assessed using well-established performance tests. Self-reported function was measured using the Short Musculoskeletal Function Assessment (SMFA). The Orthotics and Prosthetics Users' Survey was administered to assess satisfaction with the IDEO. Of 87 participants with complete baseline data, 6 did not complete any physical therapy and were excluded from the analysis. Follow-up rates immediately following completion of the RTR PT and at 6 and 12 months were 88%, 75%, and 79%, respectively.
RESULTS: Compared with baseline, improvement at completion of RTR PT was observed in all but 1 performance test. SMFA scores for all domains except hand and arm function were lower (improved function) at 6 and 12 months. Satisfaction with the IDEO was high following completion of RTR PT, with some attenuation at the time of follow-up.
CONCLUSIONS: This study adds to the evidence supporting the efficacy of the IDEO coupled with RTR PT. However, despite improvement in both performance and self-reported functioning, deficits persist compared with population norms. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30334889     DOI: 10.2106/JBJS.18.00213

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  4 in total

Review 1.  How New Technology Is Improving Physical Therapy.

Authors:  Johnny G Owens; Michelle R Rauzi; Andrew Kittelson; Jeremy Graber; Michael J Bade; Julia Johnson; Dustin Nabhan
Journal:  Curr Rev Musculoskelet Med       Date:  2020-04

2.  CORR Insights®: Military Service Members with Major Lower Extremity Fractures Return to Running with a Passive-dynamic Ankle-foot Orthosis: Comparison with a Normative Population.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2021-11-01       Impact factor: 4.755

3.  Custom Dynamic Orthoses and Physical Therapist Intervention for Bilateral Midfoot Amputation: A Case Report.

Authors:  Kirsten M Anderson; Richard E Evans; Charles E Connerly; Molly Pacha; Jason M Wilken
Journal:  Phys Ther       Date:  2021-04-04

4.  Military Service Members with Major Lower Extremity Fractures Return to Running with a Passive-dynamic Ankle-foot Orthosis: Comparison with a Normative Population.

Authors:  Shian Liu Peterson; Trevor D Kingsbury; Tatiana Djafar; Julianne Stewart; Kevin M Kuhn
Journal:  Clin Orthop Relat Res       Date:  2021-11-01       Impact factor: 4.755

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.