Literature DB >> 30325268

Direct electrochemical detection of glyphosate at carbon paste electrode and its determination in samples of milk, orange juice, and agricultural formulation.

Pâmela C Oliveira1, Elizabete M Maximiano1, Poliane A Oliveira1, Junior S Camargo1, Antonio R Fiorucci1, Gilberto J Arruda1.   

Abstract

This paper describes a simple, inexpensive, highly sensitive, selective, and efficient electrochemical method to determine glyphosate (GLY) in samples of milk, orange juice, and agricultural formulation. The oxidation reaction on the electrode surface was electrochemically characterised by cyclic voltammetry (CV) and square wave voltammetry (SWV). The investigation of GLY at carbon paste electrode revealed a non-reversible oxidation peak at +0.95 V versus Ag/AgCl, which was used for electrochemical detection of GLY. The operating parameters (pH, frequency, step potential, and amplitude) were optimised in relation to the peak current intensity, and a calibration curve was set up in a concentration range of 4.40 × 10-8-2.80 × 10-6 mol L-1, with a detection limit of 2 × 10-9 mol L-1. After calibration curve was plotted, the developed procedure was applied to determine GLY in previously contaminated samples: milk and orange juice, and in a commercial formulation, obtaining recovery values between 98.31% and 103.75%. These results show that the proposed method can be used for GLY quantification in different samples with high sensitivity, specificity, stability, and reproducibility.

Entities:  

Keywords:  Glyphosate; agricultural formulation; carbon paste electrode; milk; orange juice

Mesh:

Substances:

Year:  2018        PMID: 30325268     DOI: 10.1080/03601234.2018.1505081

Source DB:  PubMed          Journal:  J Environ Sci Health B        ISSN: 0360-1234            Impact factor:   1.990


  3 in total

Review 1.  Recent Progress in Non-Enzymatic Electroanalytical Detection of Pesticides Based on the Use of Functional Nanomaterials as Electrode Modifiers.

Authors:  Tanja Vrabelj; Matjaž Finšgar
Journal:  Biosensors (Basel)       Date:  2022-04-20

Review 2.  Recent Development on the Electrochemical Detection of Selected Pesticides: A Focused Review.

Authors:  Jafar Safaa Noori; John Mortensen; Alemnew Geto
Journal:  Sensors (Basel)       Date:  2020-04-15       Impact factor: 3.576

3.  Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate.

Authors:  Zachary T Johnson; Nathan Jared; John K Peterson; Jingzhe Li; Emily A Smith; Scott A Walper; Shelby L Hooe; Joyce C Breger; Igor L Medintz; Carmen Gomes; Jonathan C Claussen
Journal:  Glob Chall       Date:  2022-07-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.