Literature DB >> 30324427

Characteristics of iodine-123 IQ-SPECT/CT imaging compared with conventional SPECT/CT.

Takayuki Shibutani1, Masahisa Onoguchi2, Hiroto Yoneyama3, Takahiro Konishi3, Shinro Matsuo4, Kenichi Nakajima4.   

Abstract

OBJECTIVES: Although the utility of IQ-SPECT imaging using 99mTc and 201Tl myocardial perfusion SPECT has been reported, 123I-labeled myocardial SPECT has not been fully evaluated. We determined the characteristics and utility of 123I IQ-SPECT imaging compared with conventional SPECT (C-SPECT).
METHODS: Two myocardial phantom patterns were used to simulate normal myocardium and myocardial infarction. SPECT acquisition was performed using a hybrid dual-head SPECT/CT system equipped with a SMARTZOOM collimator for IQ-SPECT or a low-medium energy general purpose collimator for C-SPECT. Projection data were reconstructed using ordered subset expectation maximization with depth-dependent 3-dimensional resolution recovery for C-SPECT and ordered subset conjugate gradient minimizer method for IQ-SPECT. Three types of myocardial image were created; namely, no correction (NC), with attenuation correction (AC), and with both attenuation and scatter corrections (ACSC). Five observers visually scored the homogeneity of normal myocardium and defect severity of the myocardium with inferior defects by a five-point scale: homogeneity scores (5 = homogeneous to 1 = inhomogeneous) and defect scores (5 = excellent to 1 = poor). We also created a 17-segment polar map and quantitatively assessed segmental %uptake using a myocardial phantom with normal findings and defects.
RESULTS: The average visual homogeneity scores of the IQ-SPECT with NC and ACSC were significantly higher than that of C-SPECT, whereas the average visual defect scores of IQ-SPECT with AC and ACSC were significantly lower. The %uptake of all segments for IQ-SPECT with NC was significantly higher than that of C-SPECT. Furthermore, the subtraction of %uptake for C-SPECT and IQ-SPECT was the largest in inferior wall, which was approximately 10.1%, 14.7% and 14.4% for NC, AC and ACSC, respectively. The median % uptake values of the inferior wall with defect areas for C-SPECT and IQ-SPECT were 46.9% and 50.7% with NC, 59.8% and 69.2% with AC, and 54.7% and 66.5% with ACSC, respectively.
CONCLUSION: 123I IQ-SPECT imaging significantly improved the attenuation artifact compared with C-SPECT imaging. Although the defect detectability of IQ-SPECT was inferior to that of C-SPECT, 123I IQ-SPECT images with NC and ACSC met the criteria for defect detectability. Use of 123I IQ-SPECT is suitable for routine examinations.

Entities:  

Keywords:  IQ-SPECT; Iodine-123; Multi-focus collimator; OSCGM; Short acquisition

Mesh:

Substances:

Year:  2018        PMID: 30324427     DOI: 10.1007/s12149-018-1310-8

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  2 in total

1.  CT Imaging Characteristics and Influence Factors of Renal Dialysis-Associated Peritoneal Injury.

Authors:  Jin Tong; Wangda Xu
Journal:  J Healthc Eng       Date:  2021-04-20       Impact factor: 2.682

2.  Uniformity of cardiac 123I-MIBG uptake on SPECT images in older adults with normal cognition and patients with dementia.

Authors:  Gemma Roberts; Jim J Lloyd; Elizabeth Jefferson; Joseph P M Kane; Rory Durcan; Sarah Lawley; George S Petrides; Kim Howe; Iftikhar Haq; John T O'Brien; Alan J Thomas
Journal:  J Nucl Cardiol       Date:  2019-12-09       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.