Literature DB >> 30318543

A novel paper-based colorimetry device for the determination of the albumin to creatinine ratio.

Sudkate Chaiyo1, Kurt Kalcher, Amara Apilux, Orawon Chailapakul, Weena Siangproh.   

Abstract

A novel paper-based analytical device (PAD) was fabricated and developed for the simple and rapid determination of the albumin to creatinine ratio (ACR) in urine samples. The detection was based on a colorimetric reaction using bromocresol green (BG) in a phosphate buffer (PB) at pH 4 for the determination of albumin (AL) and creatinine (CR). BG changes color from greenish-yellow to bluish-green in the presence of AL and/or CR. Picric acid (PA) in 0.25 M NaOH was used to detect CR, and PA changes color from yellow to orange. Under the optimal conditions, the working range was 10 to 350 mg dL-1 with a detection limit of 7.1 and 5.4 mg dL-1 for AL + CR and CR detection, respectively. The repeatability was evaluated, and the %RSD value was less than 8.23 (n = 10). The ACR was obtained by calculating the AL and CR colorimetric results. Finally, the proposed devices were applied to the determination of AL, CR, and ACR in urine samples. The results obtained by the developed PADs were in good agreement with the standard method and demonstrated the method could reliably measure AL, CR, and ACR. The proposed method provides a low-cost, simple, sensitive, and promising tool for diagnostic identification assay for chronic kidney disease (CKD).

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30318543     DOI: 10.1039/c8an01122b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  Automated Paper-Based Femtogram Sensing Device for Competitive Enzyme-Linked Immunosorbent Assay of Aflatoxin B1 Using Submicroliter Samples.

Authors:  Sumamal Charernchai; Miyuki Chikae; Tue Trong Phan; Wanida Wonsawat; Daisuke Hirose; Yuzuru Takamura
Journal:  Anal Chem       Date:  2022-03-18       Impact factor: 6.986

Review 2.  Recent advances in nephropathy biomarker detections using paper-based analytical devices.

Authors:  Akhmad Sabarudin; Setyawan P Sakti; Hani Susianti; Nur Samsu; Ika O Wulandari; Yudit Oktanella; Dewi Anggraeni
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

Review 3.  Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review.

Authors:  Wei-Chun Tai; Yu-Chi Chang; Dean Chou; Lung-Ming Fu
Journal:  Biosensors (Basel)       Date:  2021-08-03

Review 4.  Colorimetric and Electrochemical Screening for Early Detection of Diabetes Mellitus and Diabetic Retinopathy-Application of Sensor Arrays and Machine Learning.

Authors:  Georgina Faura; Gerard Boix-Lemonche; Anne Kristin Holmeide; Rasa Verkauskiene; Vallo Volke; Jelizaveta Sokolovska; Goran Petrovski
Journal:  Sensors (Basel)       Date:  2022-01-18       Impact factor: 3.576

5.  Microfluidic Sliding Paper-Based Device for Point-of-Care Determination of Albumin-to-Creatine Ratio in Human Urine.

Authors:  Szu-Jui Chen; Chin-Chung Tseng; Kuan-Hsun Huang; Yu-Chi Chang; Lung-Ming Fu
Journal:  Biosensors (Basel)       Date:  2022-07-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.