A machine learning pipeline for internal anatomical landmark embedding based on a patient surface model.

Xia Zhong1, Norbert Strobel2, Annette Birkhold3, Markus Kowarschik3, Rebecca Fahrig3, Andreas Maier4.   

Abstract

PURPOSE: With the recent introduction of fully assisting scanner technologies by Siemens Healthineers (Erlangen, Germany), a patient surface model was introduced to the diagnostic imaging device market. Such a patient representation can be used to automate and accelerate the clinical imaging workflow, manage patient dose, and provide navigation assistance for computed tomography diagnostic imaging. In addition to diagnostic imaging, a patient surface model has also tremendous potential to simplify interventional imaging. For example, if the anatomy of a patient was known, a robotic angiography system could be automatically positioned such that the organ of interest is positioned in the system's iso-center offering a good and flexible view on the underlying patient anatomy quickly and without any additional X-ray dose.
METHOD: To enable such functionality in a clinical context with sufficiently high accuracy, we present an extension of our previous patient surface model by adding internal anatomical landmarks associated with certain (main) bones of the human skeleton, in particular the spine. We also investigate different approaches to positioning of these landmarks employing CT datasets with annotated internal landmarks as training data. The general pipeline of our proposed method comprises the following steps: First, we train an active shape model using an existing avatar database and segmented CT surfaces. This stage also includes a gravity correction procedure, which accounts for shape changes due to the fact that the avatar models were obtained in standing position, while the CT data were acquired with patients in supine position. Second, we match the gravity-corrected avatar patient surface models to surfaces segmented from the CT datasets. In the last step, we derive the spatial relationships between the patient surface model and internal anatomical landmarks. RESULT: We trained and evaluated our method using cross-validation using 20 datasets, each containing 50 internal landmarks. We further compared the performance of four different generalized linear models' setups to describe the positioning of the internal landmarks relative to the patient surface. The best mean estimation error over all the landmarks was achieved using lasso regression with a mean error of [Formula: see text].
CONCLUSION: Considering that interventional X-ray imaging systems can have detectors covering an area of about [Formula: see text] ([Formula: see text]) at iso-center, this accuracy is sufficient to facilitate automatic positioning of the X-ray system.

Entities:  

Keywords:  Anatomical landmark; Imaging; Interventional; Patient modeling; Statistical shape model; X-ray

Mesh:

Year:  2018        PMID: 30317437     DOI: 10.1007/s11548-018-1871-y

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  9 in total

1.  Nonlinear dimensionality reduction by locally linear embedding.

Authors:  S T Roweis; L K Saul
Journal:  Science       Date:  2000-12-22       Impact factor: 47.728

2.  Minimum-distortion isometric shape correspondence using EM algorithm.

Authors:  Yusuf Sahillioğlu; Yücel Yemez
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2012-11       Impact factor: 6.226

3.  Scale-invariant features for 3-D mesh models.

Authors:  Tal Darom; Yosi Keller
Journal:  IEEE Trans Image Process       Date:  2012-01-09       Impact factor: 10.856

4.  Skin dose mapping for fluoroscopically guided interventions.

Authors:  Perry B Johnson; David Borrego; Stephen Balter; Kevin Johnson; Daniel Siragusa; Wesley E Bolch
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Real-Time Respiratory Motion Analysis Using 4-D Shape Priors.

Authors:  Jakob Wasza; Peter Fischer; Heike Leutheuser; Tobias Oefner; Christoph Bert; Andreas Maier; Joachim Hornegger
Journal:  IEEE Trans Biomed Eng       Date:  2015-08-03       Impact factor: 4.538

6.  Verification of the performance accuracy of a real-time skin-dose tracking system for interventional fluoroscopic procedures.

Authors:  Daniel R Bednarek; Jeffery Barbarits; Vijay K Rana; Srikanta P Nagaraja; Madhur S Josan; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-13

7.  Estimating a patient surface model for optimizing the medical scanning workflow.

Authors:  Vivek Singh; Yao-Jen Chang; Kai Ma; Michael Wels; Grzegorz Soza; Terrence Chen
Journal:  Med Image Comput Comput Assist Interv       Date:  2014

8.  Cloud-Based Evaluation of Anatomical Structure Segmentation and Landmark Detection Algorithms: VISCERAL Anatomy Benchmarks.

Authors:  Oscar Jimenez-Del-Toro; Henning Muller; Markus Krenn; Katharina Gruenberg; Abdel Aziz Taha; Marianne Winterstein; Ivan Eggel; Antonio Foncubierta-Rodriguez; Orcun Goksel; Andras Jakab; Georgios Kontokotsios; Georg Langs; Bjoern H Menze; Tomas Salas Fernandez; Roger Schaer; Anna Walleyo; Marc-Andre Weber; Yashin Dicente Cid; Tobias Gass; Mattias Heinrich; Fucang Jia; Fredrik Kahl; Razmig Kechichian; Dominic Mai; Assaf B Spanier; Graham Vincent; Chunliang Wang; Daniel Wyeth; Allan Hanbury
Journal:  IEEE Trans Med Imaging       Date:  2016-06-09       Impact factor: 10.048

9.  Kinect-Based Correction of Overexposure Artifacts in Knee Imaging with C-Arm CT Systems.

Authors:  Johannes Rausch; Andreas Maier; Rebecca Fahrig; Jang-Hwan Choi; Waldo Hinshaw; Frank Schebesch; Sven Haase; Jakob Wasza; Joachim Hornegger; Christian Riess
Journal:  Int J Biomed Imaging       Date:  2016-07-19
  9 in total
  1 in total

1.  XDose: toward online cross-validation of experimental and computational X-ray dose estimation.

Authors:  Philipp Roser; Annette Birkhold; Alexander Preuhs; Philipp Ochs; Elizaveta Stepina; Norbert Strobel; Markus Kowarschik; Rebecca Fahrig; Andreas Maier
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-12-04       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.