| Literature DB >> 30308064 |
Samson Limbaso Konongoi1,2, Albert Nyunja2, Victor Ofula2, Samuel Owaka2, Hellen Koka2, Edith Koskei2, Fredrick Eyase2,3, Daniel Langat4, James Mancuso2, Joel Lutomiah1,2, Rosemary Sang1,2.
Abstract
Chikungunya is a reemerging vector borne pathogen associated with severe morbidity in affected populations. Lamu, along the Kenyan coast was affected by a major chikungunya outbreak in 2004. Twelve years later, we report on entomologic investigations and laboratory confirmed chikungunya cases in northeastern Kenya. Patient blood samples were received at the Kenya Medical Research Institute (KEMRI) viral hemorrhagic fever laboratory and the immunoglobulin M enzyme linked immunosorbent assay (IgM ELISA) was used to test for the presence of IgM antibodies against chikungunya and dengue. Reverse transcription polymerase chain reaction (RT-PCR) utilizing flavivirus, alphavirus and chikungunya specific primers were used to detect acute infections and representative PCR positive samples sequenced to confirm the circulating strain. Immature mosquitoes were collected from water-holding containers indoors and outdoors in the affected areas in northeastern Kenya. A total of 189 human samples were tested; 126 from Kenya and 63 from Somalia. 52.9% (100/189) tested positive for Chikungunya virus (CHIKV) by either IgM ELISA or RT-PCR. Sequence analysis of selected samples revealed that the virus was closely related to that from China (2010). 29% (55/189) of the samples, almost all from northeastern Kenya or with a history of travel to northern Kenya, tested positive for dengue IgM antibodies. Entomologic risk assessment revealed high house, container and Breteau indices of, 14.5, 41.9 and 17.1% respectively. Underground water storage tanks were the most abundant, 30.1%, of which 77.4% were infested with Aedes aegypti mosquitoes. These findings confirm the presence of active chikungunya infections in the northeastern parts of Kenya. The detection of dengue IgM antibodies concurrently with chikungunya virus circulation emphasizes on the need for improved surveillance systems and diagnostic algorithms with the capacity to capture multiple causes of arbovirus infections as these two viruses share common vectors and eco-systems. In addition sustained entomological surveillance and vector control programs targeting most productive containers are needed to monitor changes in vector densities, for early detection of the viruses and initiate vector control efforts to prevent possible outbreaks.Entities:
Mesh:
Substances:
Year: 2018 PMID: 30308064 PMCID: PMC6181335 DOI: 10.1371/journal.pone.0205058
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Map of Kenya showing regions from which human samples were obtained for testing.
Fig 2Graph showing the number of samples received and the number positive for Chikungunya and Dengue, February–June 2016.
Fig 3Phylogenetic relationships of Chikungunya virus strains.
The tree was inferred in MEGA version 7 using 1138 base pair data set that encompasses the capsid protein. The analysis involved 52 nucleotide sequences. The Kenyan dataset is in the red typeface.
The number of wet containers sampled indoors and outdoors and immature Ae. aegypti positivity rates.
| Indoor | outdoor | Total | ||||
|---|---|---|---|---|---|---|
| Container Type | Negative | Positive (%) | Negative | Positive (%) | Negative | Positive (%) |
| Underground tanks | 0 | 0 (0) | 19 | 65 (77.4) | 19 | 65 (77.4) |
| Metal/plastic | 8 | 14 (63.6) | 26 | 7 (21.2) | 34 | 21 (38.2) |
| Jerry cans | 4 | 5 (55.6) | 23 | 4 (14.8) | 27 | 9 (25) |
| Buckets | 5 | 1 (20) | 32 | 2 (5.9) | 37 | 3 (7.5) |
| Jars | 0 | 0 (0) | 6 | 0 (0) | 6 | 0 (0) |
| Ground surface tanks | 0 | 0 (0) | 1 | 3 (75) | 1 | 3 (75) |
| Plastic containers | 0 | 0 (0) | 9 | 5 (35.7) | 9 | 5 (35.7) |
| Tyres | 0 | 0 (0) | 6 | 10 (62.5) | 6 | 10 (62.5) |
| Cooking pans | 0 | 0 (0) | 4 | 1 (25) | 4 | 1 (25) |
| Small cans | 0 | 0 (0) | 18 | 0 (0) | 18 | 0 (0) |
| Potted plants | 0 | 0 (0) | 1 | 0 (0) | 1 | 0 (0) |
| 17 | 20 (54.1) | 145 | 97 (66.9) | 162 | 117 (72.2) | |
Percentages of positive containers are indicated in parenthesis within the table
* = 50–200 liters capacity