Three-dimensional transesophageal echocardiography is an attractive alternative to cardiac multi-detector computed tomography for aortic annular sizing: Systematic review and meta-analysis.

Ahmed Elkaryoni1, Navin C Nanda2, Paramdeep Baweja3, Mohammed J Arisha2, Harris Zamir1, Ahmed Elgebaly4, Ahmed Ma Altibi5, Rishi Sharma1.   

Abstract

BACKGROUND: Cardiac imaging is the cornerstone of the pretranscatheter aortic valve replacement (TAVR) assessment. Multi-detector computed tomography (MDCT) is considered the conventional imaging modality. However, there is still no definitive gold standard. Targeted cohort of inoperable high-risk patients with underlying comorbidities, particularly renal impairment, makes apparent the need for MDCT alternative. We aimed to demonstrate the correlation extent between MDCT and three-dimensional transesophageal echocardiography (3DTEE) aortic annular area measures and to answer the question: Is 3DTEE a good alternative to MDCT?
METHODS: A systematic literature search and meta-analysis were conducted to evaluate the degree of correlation and agreement between 3DTEE and MDCT aortic annular sizing. A thorough assessment of EMBASE, PubMed, and Cochrane Central Register of Controlled Trials (CENTRAL) was performed. All studies comparing 3DTEE and MDCT in relation to aortic annular sizing were included.
RESULTS: Thirteen studies were included (N = 1228 patients). A strong linear correlation was found between 3DTEE and MDCT measurements of aortic annulus area (r = 0.84, P < 0.001), mean perimeter (r = 0. 0.85, P < 0.001), and mean diameter (r = 0.80, P < 0.001). Bland-Altman plots revealed smaller mean 3DTEE values in comparison to MDCT for aortic annular area, the mean difference being -2.22 mm2 with 95% limits of agreement -12.79 to 8.36.
CONCLUSION: Aortic annulus measurements obtained by 3DTEE demonstrated a high level of correlation with those evaluated by MDCT. This makes 3DTEE a feasible choice for aortic annulus assessment, with advantage of real time assessment, lack of contrast, and no radiation exposure.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  aortic stenosis; aortic valve prosthesis; aortic valve replacement; cardiac imaging; computed tomography; three-dimensional transesophageal echocardiography

Mesh:

Year:  2018        PMID: 30296350     DOI: 10.1111/echo.14147

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

Review 1.  Preoperative TAVR Planning: How to Do It.

Authors:  Rodrigo Petersen Saadi; Ana Paula Tagliari; Eduardo Keller Saadi; Marcelo Haertel Miglioranza; Carisi Anne Polanczyck
Journal:  J Clin Med       Date:  2022-05-05       Impact factor: 4.964

2.  Meta-Analysis Comparing Renal Outcomes after Transcatheter versus Surgical Aortic Valve Replacement.

Authors:  Kuldeep Shah; Zakeih Chaker; Tatiana Busu; Rishita Shah; Mohammed Osman; Fahad Alqahtani; Mohamad Alkhouli
Journal:  J Interv Cardiol       Date:  2019-04-24       Impact factor: 2.279

Review 3.  Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Chanrith Mork; Minjie Wei; Weixi Jiang; Jianli Ren; Haitao Ran
Journal:  Diagnostics (Basel)       Date:  2021-04-22

4.  Three-Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta-Analysis.

Authors:  Lisa Q Rong; Irbaz Hameed; Arash Salemi; Mohamed Rahouma; Faiza M Khan; Harindra C Wijeysundera; Dominick J Angiolillo; Linda Shore-Lesserson; Giuseppe Biondi-Zoccai; Leonard N Girardi; Stephen E Fremes; Mario Gaudino
Journal:  J Am Heart Assoc       Date:  2019-09-24       Impact factor: 5.501