A comparative analysis of errors in inhaler technique among COPD versus asthma patients.

Birsen Ocakli1, Ipek Ozmen1, Eylem Acartürk Tunçay1, Sinem Gungor1, Hilal Altinoz1, Nalan Adiguzel1, Zafer Ali Sak2, Gokay Gungor1, Zuhal Karakurt1, Peri Arbak3.   

Abstract

PURPOSE: This study was designed to evaluate errors in inhaler technique in COPD vs asthma patients and to investigate the association of poor inhaler technique with patient demographics and clinical variables. PATIENTS AND METHODS: A total of 509 adult patients with COPD (n=328) or asthma (n=181) who were currently using an inhaler device were included in this study. Data on patient demographics, duration of disease, type and duration of inhaler therapy, and assessment of inhaler technique were recorded.
RESULTS: Metered dose inhaler (MDI) was the most common type of inhaler used by a similarly high percentage of patients in both COPD (83.2%) and asthma (77.3%) groups. Failure to exhale before inhaling through device (75.8% and 68.5% for MDIs; 73.2% and 71.8% for Aerolizer®/Handihaler®; 53.1% and 66.7% for Turbuhaler®) was the most common error in inhaler technique, in both COPD and asthma groups. Device-specific errors in inhaler techniques were more common in asthma patients as compared with COPD patients, particularly for MDIs (P-values ranged from 0.046 to 0.0005), as associated with female gender (failure to press the buttons on both sides of Aerolizer®/Handihaler®, P=0.006), shorter duration of disease (failure to hold MDI or head in a vertical position, P<0.001, and to keep Turbuhaler® upright, P=0.005), and shorter duration of inhaler usage (failure to hold head in a vertical position during MDI usage, P=0.006, and to keep Turbuhaler® upright, P=0.012).
CONCLUSION: In conclusion, our findings revealed that errors in inhaler technique in terms of inhalation maneuvers and device handling were similarly common in COPD and asthma patients. Errors in certain device handling maneuvers, particularly with MDIs, were more common among asthma patients than among COPD patients and associated with female gender and shorter durations of disease and inhaler therapy.

Entities:  

Keywords:  asthma; chronic obstructive pulmonary disease; dry powder inhalers; inhaler technique; inhaler therapy; metered dose inhalers

Mesh:

Substances:

Year:  2018        PMID: 30288037      PMCID: PMC6161718          DOI: 10.2147/COPD.S178951

Source DB:  PubMed          Journal:  Int J Chron Obstruct Pulmon Dis        ISSN: 1176-9106


Introduction

Inhaled therapy is a mainstay in the management of asthma and COPD.1–3 Metered dose inhalers (MDIs), dry powder inhalers (DPIs), and nebulizers are the most common inhaler devices used to administer aerosolized medication in routine respiratory practice.1–5 Optimal inhaler technique depends on correct preparation and handling of the device before inhalation and an optimal inhalation technique.3 Although MDIs are considered to be more difficult to use than DPIs,3,6–9 errors in inhaler technique are very common among COPD and asthma patients in daily real-life practice.3,5,10–16 Poor inhaler technique has been associated with inadequate drug delivery to the lungs and thus with poor disease control and worse disease outcomes.1–3,9,14,17–19 Recent global position documents from the Global Initiative for Asthma (GINA) and GOLD both highlight the critical importance of assessing inhaler technique to guide appropriate inhaler prescribing and correcting poor inhalation technique before escalating drug therapy.20,21 However, published data on the interaction between patient, device, and inhaler technique are considered to be insufficient and inconsistent.19 Moreover, comparison of inhaler techniques in COPD vs asthma patients also revealed inconsistent findings with similar rate of errors14,17,19 or higher odds of incorrect inhaler technique in COPD patients than in asthma patients,8 after adjusting for age, gender, and level of education. Indeed, older age and higher prevalence of comorbidities in COPD patients have been associated with a higher likelihood of poor inhaler technique as compared with asthma patients.3,8 In addition, discordance between self-assessment and medical supervision in terms of rates of correct inhaler technique has been noted in COPD and asthma patients, while COPD patients were reported to be more uncertain with MDI technique on self-assessment and to make more errors during direct observation when compared to asthmatics.22 Being addressed in a limited number of studies to date, the differences between asthma and COPD in terms of etiology, symptoms, pathophysiology, consequences of inflammation, response to therapy, and clinical course may affect the inhaler performance of patients. Thus, comparison of inhaler technique among COPD and asthma patients may help to better understand how to improve the use of inhalers. This study was therefore designed to comparatively evaluate errors in inhaler technique in COPD vs asthma patients and to investigate the association of poor inhaler technique with patient demographics and clinical variables.

Material and methods

Study population

A total of 509 adult patients with COPD (n=328) or asthma (n=181) who were currently using at least one inhaler device for at least 1 month were included in this cross-sectional, observational study conducted at a tertiary pneumology outpatient clinic from February to May 2018. MDI, Aerolizer®/Handihaler®, Diskus®, and Turbuhaler® were assessed in this study as the most commonly used devices of those available in Turkey. Patients aged >18 years and diagnosed with asthma according to the GINA20 or with COPD according to the GOLD21 were included in the study. Use of inhaler therapy for less than a month, lack of attendance of regular control visits, confirmed or suspected pregnancy, breastfeeding, allergy, sensitivity or intolerance to asthma or COPD therapy, and being on nebulizer therapy per se were the exclusion criteria of the study. Written informed consent was obtained from each subject following a detailed explanation of the objectives and protocol of the study, which was conducted in accordance with the ethical principles stated in the Declaration of Helsinki and approved by the University of Health Sciences, Sureyyapasa Chest Diseases and Thoracic Surgery Training and Research Hospital Ethics Committee (date of approval: February 5, 2018, protocol number: 018).

Data collection

Data on patient demographics (age, gender), duration of disease, type and duration of inhaler therapy, and assessment of inhaler technique (correct, incorrect) were recorded in COPD and asthma groups. The inhaler technique for each device was evaluated through direct observation of patient’s performance using checklists developed in-house specifically for each inhaler device based on the manufacturers’ instructions and recommendations for correct implementation of inhalers provided by Turkish Thoracic Society Patient Information Handbook on Asthma23 and Turkish Thoracic Society National Asthma Diagnosis and Management Guidelines.24 The same interviewer, who was an experienced respiratory technician blinded to diagnosis group, registered whether each step was performed properly and in an adequate order, and errors in inhaler technique were compared between COPD and asthma groups. Errors in maneuvers that significantly differed between patients with COPD and asthma were further analyzed in relation to demographic and disease-related characteristics.

Statistical analysis

Statistical analysis was performed using IBM SPSS Statistics for Windows, version 21.0 (IBM Corporation, Armonk, NY, USA). Chi-squared test was used to analyze the comparison of categorical data between COPD and asthma groups and to analyze the influence of gender on errors in inhaler techniques that differed between COPD and asthma groups. Student’s t-test and Mann–Whitney U test were used for sub-analysis of errors in inhaler techniques that differed between COPD and asthma groups in terms of age and duration of disease and inhaler therapy. Data were expressed as mean SD, percent (%), and minimum-maximum where appropriate. P<0.05 was considered statistically significant.

Results

Demographic and clinical characteristics in COPD and asthma groups

The COPD group was associated with older patient age (mean SD 64.6 [10.3, 29–89] vs 56.0 [14.5, 17–90] years, P<0.001) and higher percentage of males (65.2% vs 22.7%, P<0.001) than the asthma group (Table 1).
Table 1

Baseline characteristics of patients in COPD and asthma groups

Patient demographicsCOPD (n=328)Asthma (n=181)P-value

Age (years), mean (SD, min-max)64.6 (10.3, 29-89)56.0 (14.5, 17-90)<0.001a
Gender, n (%)
Female114 (34.8)140 (77.3)<0.001b
Male214 (65.2)41 (22.7)
Duration (years), mean (SD, min-max)
Disease9.5 (7.7, 0-40)9.2 (9.5, 0-46)0.727c
Inhaler therapy8.0 (6.6, 0-35)7.0 (7.6, 0-40)0.146c
Inhaler type, n (%)
MDI273 (83.2)140 (77.3)0.067b
Aerolizer®/Handihaler®249 (75.9)69 (38.1)<0.001b
Diskus®78 (23.8)75 (41.4)<0.001b
Turbohaler®34 (10.4)43 (23.8)<0.001b
Nebulizer111 (33.8)32 (17.7)<0.001b

Notes:

Student’s t-test;

Chi-square test;

Mann–Whitney U test.

Abbreviation: MDI, metered dose inhaler.

MDI was the most common type of inhaler used by a similarly high percentage of patients in both COPD (83.2%) and asthma (77.3%) groups, followed by Aerolizer®/Handihaler® (75.9%) type of inhalers in COPD group and by Diskus® (41.4%) in the asthma group (Table 1).

Errors in inhaler technique in COPD and asthma groups

In both COPD and asthma patients, errors in inhalation maneuvers were the most prevalent errors, including failure to exhale before inhaling through device (75.8% and 68.5% for MDIs; 73.2% and 71.8% for Aerolizer®/Handihaler®; 53.1% and 66.7% for Turbuhaler®) and failure to deeply inhale (75.0% and 80.0%) for Diskus® type inhalers (Table 2).
Table 2

Errors in inhaler technique in COPD and asthma groups

Patients with errors, n (%)P-value
Instructions for MDICOPD (n=223)Asthma (n=124)

Take off the inhaler cap18 (14.5)18 (8.1)0.046
Shake the MDI before use114 (51.1)71 (57.3)0.162
Hold the MDI in a vertical position22 (9.9)24 (19.4)0.01 1
Hold your head in a vertical position22 (9.9)25 (20.2)0.007
Exhale before use169 (75.8)85 (68.5)0.092
Put the mouthpiece in your mouth, and close your lips39 (17.5)23 (18.5)0.456
Press the canister when inhaling slowly36 (16.1)24 (19.4)0.269
Inhale deeply96 (43.0)48 (38.7)0.251
Hold your breath for 10 seconds58 (26.0)36 (29.0)0.314
Exhale and wait for 30-60 seconds before the other puff32 (14.3)14 (1 1.3)0.263

Instructions for Aerolizer®/Handihaler®COPD (n=205)Asthma (n=78)

Pull off the Aerolizer cover20 (9.8)12 (15.4)0.131
Open the mouthpiece of Aerolizer20 (9.8)11 (14.1)0.200
Remove the capsule from the package and put it into the space27(13.2)14 (17.9)0.201
Press the buttons on both sides of Aerolizer55 (26.8)41 (52.6)0.0005
Hold your head in a vertical position30 (14.6)13 (16.7)0.398
Turn your head away from Aerolizer and exhale150 (73.2)56 (71.8)0.463
Put the mouthpiece in your mouth, and close your lips26 (12.7)12 (15.4)0.338
Inhale deeply93 (45.4)42 (53.8)0.382
Hold your breath for 10 seconds40 (19.5)26 (33.3)0.012
Dispose of the capsule and put the cover back on the Aerolizer20 (9.8)9(11.5)0.407

Instructions for Turbuhaler®COPD (n=32)Asthma (n=39)

Remove the cover2 (6.3)8 (20.5)0.082
Keep Turbuhaler upright2 (6.3)10 (25.6)0.029
Twist grip at the base; twist around and then back until click is heard5(15.6)8 (20.5)0.415
Hold your head in a vertical position2 (6.3)8 (20.5)0.082
Exhale17(53.1)26 (66.7)0.179
Put the mouthpiece in your mouth, and close your lips4(12.5)12 (30.8)0.059
Breathe in strongly and deeply16 (50.0)20 (51.3)0.552
Hold your breath for 10 seconds10 (31.3)11 (28.2)0.491
Breathe out gently3 (9.4)7(17.9)0.247
Put the cover back and wait for 30-60 seconds for the second dose4(12.5)7(17.9)0.385

Instructions for Diskus®COPD (n=60)Asthma (n=65)

Open Diskus by pushing the thumb grip right around until it clicks15 (25.0)18 (27.7)0.446
Hold the mouthpiece toward you and push the lever away from you until it stops6 (10.0)8 (12.3)0.452
Exhale5 (8.3)13 (20.0)0.053
Hold your head in a vertical position8 (13.3)14 (21.5)0.167
Put the mouthpiece to your lips6 (10.0)12 (18.5)0.137
Breathe in strongly and deeply45 (75.0)52 (80.0)0.324
Remove your Diskus30 (50.0)32 (49.2)0.537
Hold your breath for 10 seconds22 (36.7)21 (32.3)0.373
Breathe out gently11 (18.3)12 (18.5)0.585
Close Diskus by sliding the thumb grip back to the original position and wait for 30-60 seconds for the second dose10 (16.7)4 (6.2)0.057

Notes: Chi-square test. Values in bold indicate statistical significance (P<0.05).

Abbreviation: MDI, metered dose inhaler.

The most common errors were device-specific errors and were related to shaking the MDI device before use (51.1% and 57.3%), removing the Diskus® (50.0% and 49.2%), and pressing the buttons on both sides of Aerolizer®/Handihaler® (26.8% and 52.6%) (Table 2). Poorer inhaler technique was noted in asthma patients as compared with COPD patients with higher rate of errors in steps including taking off the inhaler cap (8.1% vs 14.5%, P=0.046), holding the MDI in a vertical position (19.4% vs 9.9%, P=0.011), and holding the head in a vertical position (20.2% vs 9.9%, P=0.007) during MDI usage, in pressing the buttons on both sides of the device (52.6% vs 26.8%, P=0.0005) and holding breath for 10 seconds (33.3% vs 19.5%, P=0.012) during Aerolizer®/Handihaler® usage, and keeping the Turbuhaler® upright (25.6% vs 6.3%, P=0.029) (Table 2).

Sub-analysis of errors in inhaler techniques that differed between COPD and asthma groups

Shorter duration of disease (failure to hold MDI or head in a vertical position, P<0.001, and to keep Turbuhaler® upright, P=0.005) and shorter duration of inhaler therapy (failure to hold head in a vertical position during MDI usage, P=0.006, and to keep Turbuhaler® upright, P=0.012) were associated with increased likelihood of device-specific errors in inhaler techniques in patients with COPD or asthma (Table 3).
Table 3

Sub-analysis of errors in inhaler techniques that differed between COPD and asthma groups

Age, mean (SD)Gender, n (%)
Duration (years), mean (SD)
MaleFemaleDiseaseInhaler therapy

Instructions for MDI
Take off the inhaler cap
 Incorrect use57.9 (10.5)17(10.0)19 (10.7)8.8 (8.8)7.5 (6.6)
 Correct use62.4 (13.0)153 (90.0)158 (89.3)9.8 (8.2)8.1 (7.1)
P-value0.0580.4810.4940.643
Hold the MDI in a vertical position
 Incorrect use60.0 (12.9)18 (10.6)28 (15.8)6.6 (4.7)6.6 (4.8)
 Correct use62.3 (12.8)152 (89.4)149 (84.2)10.0 (8.5)8.1 (7.2)
P-value0.2750.100<0.0010.180
Hold your head in a vertical position
 Incorrect use58.3 (12.7)21 (12.4)26 (14.7)6.6 (4.5)5.8 (4.5)
 Correct use62.5 (12.8)149 (87.6)151 (85.3)10.1 (8.6)8.2 (7.2)
P-value0.0440.316<0.0010.006
Instructions for Aerolizer®/Handihaler®
Press the buttons on both sides of device
 Incorrect use63.2 (12.0)41 (27.0)55 (42.0)10.0 (8.9)8.3 (8.1)
 Correct use64.0 (10.5)1 1 1 (73.0)76 (58.0)10.1 (8.5)8.2 (7.0)
P-value0.5960.0060.9100.924
Hold your breath for 10 seconds
 Incorrect use62.6 (1 1.0)40 (26.3)26 (19.8)10.7 (9.3)8.9 (8.7)
 Correct use64.1 (1 1.0)1 12 (73.7)105 (80.2)9.7 (8.3)8.0 (7.0)
P-value0.3440.1270.4250.421
Instructions for Turbuhaler®Keep inhaler upright
 Incorrect use61.9 (10.5)4 (26.3)8 (19.8)5.0 (3.2)4.3 (3.4)
 Correct use55.8 (14.3)32 (88.9)27 (77.1)9.5 (8.9)8.2 (7.4)
P-value0.1680.1580.0050.012

Notes: Chi-square test, Student’s t-test, Mann–Whitney U test. Values in bold indicate statistical significance (P<0.05).

Abbreviation: MDI, metered dose inhaler.

Failure to press the buttons on both sides of the Aerolizer®/Handihaler® was more common among females than among males (42.0% vs 27%, P=0.006) with COPD or asthma (Table 3).

Discussion

Our findings revealed that errors in inhalator technique were very frequent in both COPD and asthma patients. The inhaler techniques of COPD vs asthma patients differed mostly in certain device-specific errors rather than the inhalation maneuvers. Poor inhaler technique in device handling was associated with shorter duration of disease and inhaler therapy. MDI-type inhalers were the most commonly used inhalers in both COPD and asthma patients in our cohort. However, past studies in patients with COPD and asthma revealed more prevalent usage of DPIs (77.0%–78.9%) than MDI-(12.0%–16.8%) type inhalers.13,17,19 This seems notable given that MDIs require a good ability of hand–lung coordination and is therefore considered to be inherently more difficult to use than DPIs.13,25,26 In fact, while considered to be more likely with MDI-type inhalers,9,15,27–29 suboptimal inhaler technique is very common in real life with both MDIs and DPIs, and in the majority of asthma and COPD patients, despite advances in inhaler device technology.3,5,10–16 Overall, with no significant difference between COPD and asthma groups, the most common errors in inhaler technique for MDIs and DPIs in our cohort were failure to exhale before use of inhaler, followed by device-specific errors and failure to deeply inhale and to hold breath. In addition, errors related to device handling were common among MDI users than among DPI users. Likewise, failure to exhale before inhaling through device, inability to coordinate activation with inhalation, and failure to hold breath have also been reported to be errors in inhalation maneuvers that are common in all types of inhalers among COPD and asthma patients.13,17,30,31 In accordance with our findings, a high frequency of poor and/or suboptimal inhaler use has consistently been reported in past studies alongside a higher likelihood of errors related to device handling with use of MDIs compared with DPIs among COPD and asthma patients.9,15,29 Past studies indicated either no difference between COPD and asthma patients in terms of inhaler technique17,19,32 or higher odds of incorrect inhaler technique in COPD patients attributed to older age and higher prevalence of comorbidities.8,28,33 Although the COPD patients were older than the asthma patients in our cohort, our findings revealed no significant difference between asthma and COPD patients in terms of basic inhalation maneuvers, whereas there was poorer inhaler technique in asthma than COPD patients, particularly in certain device-specific steps. Regarding the steps that significantly differed between asthma and COPD patients, a higher likelihood of incorrect technique was associated with shorter duration of disease and therapy for MDI and Turbuhaler® users, and with female gender for Aerolizer®/Handihaler® users. This seems to support the reported association of longer duration of therapy (repeated instructions over a period of time and regular follow-ups)14,34–36 with a proper inhaler technique37 as well as higher odds ratio of poor inhaler technique reported in females as compared to males.19 Indeed, with overconfidence of patients toward use of the device, a steep rise in number of errors with a longer duration of therapy has also been noted, emphasizing a need for regular instructions and intermittent checkups of inhalation techniques, given the increased number of errors.14 In addition, the preponderance of female patients in the asthma group compared to the COPD group in our cohort seemed to also be associated with the poorer inhaler technique noted among asthma patients with regard to certain device-specific maneuvers. Hence, our findings support that structured and detailed education of patients on inhaler techniques should be an essential part of the pulmonary clinic practice.8 Past studies revealed a likelihood of incorrect use of inhaler devices even by medical personnel.38–41 In this regard, the sufficient ability of health care professionals themselves to use the inhaler devices and their awareness of all the correct steps and possible mistakes is considered to be of critical importance regarding the close follow-up of patients with repeated checking of inhaler techniques and correction of suboptimal techniques with tailored, in-depth support.3,14,34 The major strength of this study seems to be the comparative assessment of inhaler technique in a large-scale cohort of COPD vs asthma patients through direct observation of patients’ performance in real-life clinical practice and by using checklists based on the manufacturers’ instructions and national guidelines. However, certain limitations to this study should be considered. First, the cross-sectional design limits the interpretation of the findings and establishment of any cause and effect relationships. Second, inhaler technique was assessed based on frequently used type of inhalers, and several types of infrequently used inhalers could not be included in the analysis. Third, lack of data on past history of patient training in inhaler technique is another limitation which otherwise would have extended the knowledge gained in the current study.

Conclusion

In conclusion, our findings revealed that errors in inhaler technique in terms of inhalation maneuvers and device handling were similarly common in COPD and asthma patients. Errors in certain device handling maneuvers, particularly with MDIs, were more common among asthma patients than among COPD patients, and associated with female gender and shorter durations of disease and inhaler therapy. Our findings emphasize that suboptimal inhaler technique is common in real life for both MDIs and DPIs, emphasizing the potential role of regular assessment and reinforcement of correct inhalation technique in achieving treatment efficacy and improved disease outcomes.
  35 in total

1.  Device type and real-world effectiveness of asthma combination therapy: an observational study.

Authors:  David Price; Nicolas Roche; J Christian Virchow; Annie Burden; Muzammil Ali; Alison Chisholm; Amanda J Lee; Elizabeth V Hillyer; Julie von Ziegenweidt
Journal:  Respir Med       Date:  2011-05-25       Impact factor: 3.415

2.  Predictors of incorrect inhalation technique in patients with asthma or COPD: a study using a validated videotaped scoring method.

Authors:  Geert N Rootmensen; Anton R J van Keimpema; Henk M Jansen; Rob J de Haan
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2010-10       Impact factor: 2.849

3.  Study of Proper use of Inhalational Devices by Bronchial Asthma or COPD Patients Attending a Tertiary Care Hospital.

Authors:  Avijit Ganguly; Anup Kumar Das; Anindya Roy; Anjan Adhikari; Joyashree Banerjee; Sumitra Sen
Journal:  J Clin Diagn Res       Date:  2014-10-20

4.  Misuse of respiratory inhalers in hospitalized patients with asthma or COPD.

Authors:  Valerie G Press; Vineet M Arora; Lisa M Shah; Stephanie L Lewis; Krystal Ivy; Jeffery Charbeneau; Sameer Badlani; Edward Nareckas; Edward Naurekas; Antoinette Mazurek; Jerry A Krishnan
Journal:  J Gen Intern Med       Date:  2011-01-20       Impact factor: 5.128

Review 5.  Systematic Review of Errors in Inhaler Use: Has Patient Technique Improved Over Time?

Authors:  Joaquin Sanchis; Ignasi Gich; Soren Pedersen
Journal:  Chest       Date:  2016-04-07       Impact factor: 9.410

6.  Medical personnel and patient skill in the use of metered dose inhalers: a multicentric study. CESEA Group.

Authors:  V Plaza; J Sanchis
Journal:  Respiration       Date:  1998       Impact factor: 3.580

Review 7.  Optimising Inhaled Pharmacotherapy for Elderly Patients with Chronic Obstructive Pulmonary Disease: The Importance of Delivery Devices.

Authors:  Federico Lavorini; Claudia Mannini; Elisa Chellini; Giovanni A Fontana
Journal:  Drugs Aging       Date:  2016-07       Impact factor: 3.923

8.  Evaluating inhaler use technique in COPD patients.

Authors:  Chaicharn Pothirat; Warawut Chaiwong; Nittaya Phetsuk; Sangnual Pisalthanapuna; Nonglak Chetsadaphan; Woranoot Choomuang
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2015-07-08

9.  Factors influencing asthma control: results of a real-life prospective observational asthma inhaler treatment (ASIT) study.

Authors:  Füsun Yıldız
Journal:  J Asthma Allergy       Date:  2013-07-01

10.  Correct inhalation technique is critical in achieving good asthma control.

Authors:  Federico Lavorini; Omar S Usmani
Journal:  Prim Care Respir J       Date:  2013-12
View more
  12 in total

1.  Inhaler Technique in Low-Income, Inner-City Adults with Uncontrolled Asthma.

Authors:  Patrick K Gleeson; Luzmercy Perez; A Russell Localio; Knashawn H Morales; Xiaoyan Han; Tyra Bryant-Stephens; Andrea J Apter
Journal:  J Allergy Clin Immunol Pract       Date:  2019-06-05

2.  Impact of Pharmacist Education on Inhaler Technique and Adherence in an Outpatient Clinic.

Authors:  Bianca Mayzel; Sarah Muench; Colleen Lauster
Journal:  Hosp Pharm       Date:  2021-09-16

Review 3.  Inhalation Technique Errors with Metered-Dose Inhalers Among Patients with Obstructive Lung Diseases: A Systematic Review and Meta-Analysis of U.S. Studies.

Authors:  Soojin Cho-Reyes; Bartolome R Celli; Carole Dembek; Karen Yeh; Maryam Navaie
Journal:  Chronic Obstr Pulm Dis       Date:  2019-07-24

Review 4.  Performance Characteristics of Breezhaler® and Aerolizer® in the Real-World Setting.

Authors:  Mathieu Molimard; Ioannis Kottakis; Juergen Jauernig; Sonja Lederhilger; Ivan Nikolaev
Journal:  Clin Drug Investig       Date:  2021-03-25       Impact factor: 2.859

5.  The Relationship Between Clinical Trial Participation and Inhaler Technique Errors in Asthma and COPD Patients.

Authors:  Rubeshan Perumal; Marcia Leite; Richard Nellis van Zyl-Smit
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2020-06-02

6.  Pharmacist Led Intervention on Inhalation Technique among Asthmatic Patients for Improving Quality of Life in a Private Hospital of Nepal.

Authors:  Anita Yadav; Parbati Thapa
Journal:  Pulm Med       Date:  2019-11-24

7.  Effectiveness and Patient Satisfaction with Budesonide/Formoterol Easyhaler® Among Patients with Asthma or COPD Switching from Previous Treatment: a Real-World Study of Patient-Reported Outcomes.

Authors:  Gabriella Gálffy; Maria Szilasi; Lilla Tamási
Journal:  Pulm Ther       Date:  2019-07-29

8.  Comparative Study of Inhaler Device Handling Technique and Risk Factors for Critical Inhaler Errors in Korean COPD Patients.

Authors:  Jong Geol Jang; Jin Hong Chung; Kyeong-Cheol Shin; Hyun Jung Jin; Kwan Ho Lee; June Hong Ahn
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-04-19

9.  Treatment patterns and cost of exacerbations in patients with chronic obstructive pulmonary disease using multiple inhaler triple therapy in South Korea.

Authors:  Chang-Hoon Lee; Mi-Sook Kim; See-Hwee Yeo; Chin-Kook Rhee; Heung-Woo Park; Bo-Ram Yang; Joongyub Lee; Eun-Yeong Cho; Xiaomeng Xu; Aldo Amador Navarro Rojas; Sumitra Shantakumar; Dominique Milea; Nam-Kyong Choi
Journal:  Respir Res       Date:  2022-09-05

10.  Effect of an Educational Program on Healthcare Professionals' Readiness to Support Patients with Asthma, Allergies, and Chronic Obstructive Lung Disease for Improved Medication Adherence.

Authors:  Malin Axelsson; Benita Björk; Ulrika Berg; Karin Persson
Journal:  Nurs Res Pract       Date:  2020-10-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.