Literature DB >> 30285079

Agreement Between the Spatiotemporal Gait Parameters of Healthy Adults From the OptoGait System and a Traditional Three-Dimensional Motion Capture System.

Aoife Healy1, Kimberley Linyard-Tough1, Nachiappan Chockalingam1.   

Abstract

While previous research has assessed the validity of the OptoGait system to the GAITRite walkway and an instrumented treadmill, no research to date has assessed this system against a traditional three-dimensional motion analysis system. Additionally, previous research has shown that the OptoGait system shows systematic bias when compared to other systems due to the configuration of the system's hardware. This study examined the agreement between the spatiotemporal gait parameters calculated from the OptoGait system and a three-dimensional motion capture (14 camera Vicon motion capture system and 2 AMTI force plates) in healthy adults. Additionally, a range of filter settings for the OptoGait were examined to determine if it was possible to eliminate any systematic bias between the OptoGait and the three-dimensional motion analysis system. Agreement between the systems was examined using 95% limits of agreement by Bland and Altman and the intraclass correlation coefficient. A repeated measure ANOVA was used to detect any systematic differences between the systems. Findings confirm the validity of the OptoGait system for the evaluation of spatiotemporal gait parameters in healthy adults. Furthermore, recommendations on filter settings which eliminate the systematic bias between the OptoGait and the three-dimensional motion analysis system are provided.

Mesh:

Year:  2019        PMID: 30285079     DOI: 10.1115/1.4041619

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  4 in total

1.  Agreement Between the OptoGait and Instrumented Treadmill System for the Quantification of Spatiotemporal Treadmill Running Parameters.

Authors:  Amy N Weart; Erin M Miller; Gregory M Freisinger; Michael R Johnson; Donald L Goss
Journal:  Front Sports Act Living       Date:  2020-10-23

2.  How We Found Our IMU: Guidelines to IMU Selection and a Comparison of Seven IMUs for Pervasive Healthcare Applications.

Authors:  Lin Zhou; Eric Fischer; Can Tunca; Clemens Markus Brahms; Cem Ersoy; Urs Granacher; Bert Arnrich
Journal:  Sensors (Basel)       Date:  2020-07-22       Impact factor: 3.576

3.  Differences between Systems Using Optical and Capacitive Sensors in Treadmill-Based Spatiotemporal Analysis of Level and Sloping Gait.

Authors:  Dimitris Mandalidis; Ioannis Kafetzakis
Journal:  Sensors (Basel)       Date:  2022-04-05       Impact factor: 3.576

4.  Agreement Between Spatiotemporal Gait Parameters Measured by a Markerless Motion Capture System and Two Reference Systems-a Treadmill-Based Photoelectric Cell and High-Speed Video Analyses: Comparative Study.

Authors:  Felipe García-Pinillos; Diego Jaén-Carrillo; Victor Soto Hermoso; Pedro Latorre Román; Pedro Delgado; Antonio Carton; Cristian Martinez; Luis Roche Seruendo
Journal:  JMIR Mhealth Uhealth       Date:  2020-10-23       Impact factor: 4.773