Literature DB >> 30280310

Impact of fixation, coil, and number of excitations on diffusion tensor imaging of rat brains at 7.0 T.

Chunhua Wang1, Li Song1, Ruzhi Zhang1, Fabao Gao2.   

Abstract

BACKGROUND: We sought to compare diffusion tensor imaging (DTI) parameters in vivo and ex vivo in the brain and to explore the effects of radiofrequency coil and number of excitations on ex vivo DTI parameters.
METHODS: Six Sprague-Dawley rat brains were used to obtain in vivo and ex vivo DTI maps with different coils and number of excitations. DTI parameters of white matter and grey matter including diffusivities, fractional anisotropy, and other dimensionless ratios (λ2/λ1, λ3/λ1, and λ2/λ3) were obtained from reconstruction maps. Comparisons of ex vivo signal-to-noise ratio with different coils and number of excitations were conducted.
RESULTS: Diffusivities decreased significantly after fixation in all the selected white matter and grey matter regions of interest (all at p < 0.001). The diffusivities in white matter integrity decreased more than in grey matter integrity after fixation (all at p < 0.001). The ratio of λ2/λ3 in the major brain structures changed after fixation (most at p < 0.05). There were differences in major ex vivo brain structures in DTI parameters and signal-to-noise ratio between surface coil and volume coil, and between one and four excitations (most at p < 0.05).
CONCLUSION: The impact of fixation, coil, and number of excitations on DTI parameters should be taken into consideration in clinical and experimental studies at 7.0 T.

Entities:  

Keywords:  Brain; Diffusion tensor imaging; Histological techniques; Magnetic resonance imaging; Rats (all MESH terms)

Year:  2018        PMID: 30280310      PMCID: PMC6168442          DOI: 10.1186/s41747-018-0057-2

Source DB:  PubMed          Journal:  Eur Radiol Exp        ISSN: 2509-9280


Key points

Diffusivities of rat brain at 7.0 T were lower ex vivo than in vivo. The dimensionless parameters were different under different scan conditions. DTI studies should consider the effects of fixation, coil, and number of excitations.

Background

Diffusion tensor imaging (DTI) has been recognised to be able to characterize the central nervous system tissues, including the white matter (WM) and grey matter (GM) [1-3]. The main and essential DTI parameters are eigenvalues, sorted into the longest diffusivity (λ1), intermediate diffusivity (λ2), and lowest diffusivity (λ3) in the ellipsoid model [4]. On the basis of the eigenvalues, the conventionally used indices include axial diffusivity (AD, i.e. λ1), radial diffusivity (RD), mean diffusivity (MD), and fractional anisotropy (FA). Usually, DTI parameters change after axonal damage, demyelination, cerebral ischaemia, traumatic brain injury, and other nervous system diseases [5-9]. However, in vivo DTI has a disadvantage in that it is vulnerable to movement and it is time-consuming to acquire images with high resolution. Therefore, ex vivo DTI is widely used to acquire high-quality images with high resolution in clinical and basic studies with long-time scanning [10-12]. Moreover, high b value, thin slice, and a greater number of excitations are possible with ex vivo DTI. Previous studies have compared in vivo and ex vivo characteristics of DTI, finding that the diffusion decreased after fixation [12-14]. There were different results of comparison of FA in vivo and ex vivo in previous studies [14-16]. However, the scan conditions were not rigorously controlled in most previous investigations. To date, few studies have systematically compared the live and fixed DTI features under the same imaging conditions. In addition, the effects of radiofrequency coil and number of excitations on ex vivo DTI parameters remain to be determined. Therefore, we aimed at comparing in vivo and ex vivo DTI parameters under the same scan conditions and evaluating the effects of coil and number of excitations on ex vivo DTI.

Methods

In vivo and ex vivo preparations

All the procedures and experiments were approved by local Experimental Animal Ethics Committee. Six male Sprague–Dawley rats (body weight 380 ± 27 g, mean ± standard deviation) were used for the in vivo and ex vivo DTI studies. For in vivo preparation, rats were anaesthetised with isoflurane (3% for induction, 2–2.5% for maintenance, depending on respiration). Respiration and body temperature were continuously monitored during the scanning. For ex vivo preparation, brains were fixed by transcardial perfusion with 4% paraformaldehyde after euthanasia. The fixed brains were placed in plastic tubes with 4% paraformaldehyde and stored at 4 °C for more than 2 days. Before the scanning, the excised brains were immersed in the oil named Fomblin (Solvay, Brussels, Belgium) and sealed with plastic film to reduce susceptibility artefacts.

DTI acquisition

Magnetic resonance imaging was performed on a 7.0 T animal Scanner (Biospec 70/30, Bruker, Ettlingen, Germany). The brain receiving surface coil with a transmit radiofrequency coil was used for both in vivo and ex vivo brain imaging, whereas a volume coil with a 23-mm inner diameter and 44-mm outer diameter for both transmission and reception was only available for fixed brains, due to the size. After a shim, DTI images were acquired with the echo planar imaging sequence with 30 diffusion gradient directions (b = 1000 s/mm2), diffusion gradient duration/separation 4/20 ms, gradient speed 3353.45 T/m/s, repetition time/echo time 6250/ 32.2 ms, field of view 35 mm × 35 mm, matrix 128 × 128, and slice thickness 1 mm. Five additional DTI images with b = 0 s/mm2 were also obtained. One excitation was used in vivo, and both one and four excitations were used ex vivo. The scanning duration was about 15 min for one excitation and 60 min for four excitations.

Data analysis

Maps of anisotropic parameters including λ1, λ2, λ3, MD, and FA were reconstructed by ParaVision version 5.0 (Bruker, Ettlingen, Germany) using diffusion-weighted images. A reconstruction filter was used for the correction of the phase mismatch between even and odd echoes in ParaVision version 5.0. RD was calculated, where the formula is: RD = (λ2 + λ3)/2 MD is the mean of λ1, λ2, and λ3. We also used λ1, λ2, and λ3 to calculate the dimensionless ratios of λ2/λ1 (R1), λ3/λ1 (R2), and λ2/λ3 (R3). The fractional reduction of different diffusivities after fixation was computed by using the equation: (D-D)/D (Din) is in vivo diffusivity and (Dex) is ex vivo diffusivity. The regions of interest (ROIs) comprised WM ROIs of the corpus callosum, external capsule, anterior commissure, and optic tract and GM ROIs of the cortex, hippocampus, and striatum [13, 17, 18]. Two to three axial slices were selected to bilaterally delineate each ROI for the mean value. Additionally, the internal capsule and cerebral peduncle were measured together as a WM ROI because the posterior internal capsule is near the cerebral peduncle while the anterior internal capsule was difficult to outline under the thickness of 1 mm. WM integrity was defined as all the WM ROIs as a whole, and GM integrity was defined as all the WM ROIs as a whole. Signal-to-noise ratio (SNR) was defined as the mean signal intensity acquired from reconstructed intensity maps in each ROI against the standard deviation of the background noise (4 mm2 box) divided by 0.66, in consideration of Rayleigh statistics [19].

Statistical analysis

Data were expressed as mean ± standard deviation (n = 6). SPSS 22 (IBM Corp., Armonk NY, USA) was used for statistical analysis. The paired t test was used for comparisons between in vivo and ex vivo parameters, between surface coil and volume coil ex vivo parameters, and between one and four excitations ex vivo. The data on WM integrity and GM integrity were compared using the independent-samples t test. A p value < 0.05 (two-tailed) was considered statistically significant.

Results

Comparisons of DTI parameters between WM integrity and GM integrity

FA and R3 of WM integrity were significantly higher than those of GM integrity both in vivo and ex vivo under different scanning conditions (all at p < 0.001; Fig. 1). Nevertheless, RD, R1, and R2 of WM integrity were significantly lower than those of GM integrity both in vivo and ex vivo under different scanning conditions (all at p < 0.001; Fig. 1). AD in WM integrity was similar to that in GM integrity.
Fig. 1

Comparisons between white matter (WM) integrity and grey matter (GM) integrity in fractional anisotropy (FA), radial diffusivity (RD), λ2/λ1 ratio (R1), λ3/λ1 ratio (R2), and λ2/λ3 ratio (R3). There was higher FA and R3 in WM integrity than in GM integrity on both in vivo (IV) and ex vivo scans, whereas there was lower RD, R1, and R2 in WM integrity than GM integrity (all at p < 0.001). SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations

Comparisons between white matter (WM) integrity and grey matter (GM) integrity in fractional anisotropy (FA), radial diffusivity (RD), λ2/λ1 ratio (R1), λ3/λ1 ratio (R2), and λ2/λ3 ratio (R3). There was higher FA and R3 in WM integrity than in GM integrity on both in vivo (IV) and ex vivo scans, whereas there was lower RD, R1, and R2 in WM integrity than GM integrity (all at p < 0.001). SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations

Comparisons of DTI parameters in vivo and ex vivo

The comparisons of DTI parameters in vivo and ex vivo were performed with the surface coil and one excitation. The diffusivities of ex vivo ROIs were significantly lower than those of in vivo ROIs (all at p < 0.001; Table 1). The reduction of MD, AD, and RD after fixation is summarised in Table 2. Reduction of all the ROIs ranged from 0.54 to 0.70 in MD, from 0.51 to 0.70 in AD, and from 0.54 to 0.72 in RD after fixation (Table 2). The MD, AD, and RD in WM integrity decreased more than those in GM integrity after fixation (WM integrity versus GM integrity, 0.66 ± 0.05 versus 0.51 ± 0.16 in MD; 0.66 ± 0.06 versus 0.54 ± 0.06 in AD; 0.65 ± 0.06 versus 0.56 ± 0.05 in RD; all at p < 0.001). After fixation, dimensionless DTI parameters including FA, R1, and R2 in the major brain structures did not change significantly, whereas the R3 in the major brain structures changed significantly (Table 3).
Table 1

Diffusivities of in vivo and ex vivo regions of interest using the surface coil and one excitation

StructuresMean diffusivityAxial diffusivityRadial diffusivity
In vivoEx vivoIn vivoEx vivoIn vivoEx vivo
Corpus callosum8.07 ± 0.91***2.50 ± 0.312.15 ± 1.4***4.08 ± 0.496.04 ± 0.78***1.71 ± 0.2
External capsule7.81 ± 0.65***2.93 ± 0.2111.56 ± 1.03***4.20 ± 0.35.93 ± 0.49***2.30 ± 0.18
Anterior commissure7.63 ± 0.47***2.70 ± 0.3112.27 ± 0.66***4.14 ± 0.345.30 ± 0.39***1.99 ± 0.37
Internal capsule and cerebral peduncle7.76 ± 0.55***2.62 ± 0.1914.29 ± 1.12***4.60 ± 0.384.49 ± 0.44***1.63 ± 0.11
Optic tract8.88 ± 0.69***2.58 ± 0.2716.25 ± 2.07***4.59 ± 0.415.18 ± 0.17***1.58 ± 0.25
Cortex8.01 ± 0.76***3.43 ± 0.249.93 ± 1.8***4.3 ± 0.266.4 ± 0.19***2.60 ± 0.27
Hippocampus8.09 ± 0.66***3.75 ± 0.389.30 ± 1.7***4.64 ± 0.447.31 ± 0.37***3.31 ± 0.35
Striatum7.48 ± 0.34***3.43 ± 0.359.68 ± 0.74***4.47 ± 0.366.38 ± 0.17***2.91 ± 0.38

Data are presented as mean ± standard deviation (× 10− 4 mm2/s)

***p < 0.001

Table 2

Reduction of diffusivities in selected regions of interest after fixation, using the surface coil and one excitation

StructuresMean diffusivityAxial diffusivityRadial diffusivity
Corpus callosum0.68 ± 0.040.66 ± 0.050.72 ± 0.04
External capsule0.62 ± 0.030.64 ± 0.030.61 ± 0.03
Anterior commissure0.63 ± 0.070.63 ± 0.120.62 ± 0.05
Internal capsule and cerebral peduncle0.66 ± 0.030.68 ± 0.030.63 ± 0.04
Optic tract0.70 ± 0.020.70 ± 0.040.69 ± 0.05
Cortex0.56 ± 0.040.56 ± 0.060.57 ± 0.04
Hippocampus0.54 ± 0.050.51 ± 0.070.55 ± 0.05
Striatum0.54 ± 0.040.54 ± 0.030.54 ± 0.06

Data are presented as mean ± standard deviation (× 10− 4 mm2/s)

Table 3

Dimensionless DTI parameters of in vivo and ex vivo regions of interest using the surface coil and one excitation

StructuresDimensionless parametersIn vivoEx vivop value
Corpus callosumFractional anisotropy0.45 ± 0.050.55 ± 0.020.010
R1 (λ2/λ1)0.64 ± 0.040.52 ± 0.120.076 (ns)
R2 (λ3/λ1)0.37 ± 0.060.27 ± 0.030.020
R3 (λ2/λ3)1.76 ± 0.182.22 ± 0.330.057 (ns)
External capsuleFractional anisotropy0.42 ± 0.010.42 ± 0.020.555 (ns)
R1 (λ2/λ1)0.59 ± 0.090.69 ± 0.020.060 (ns)
R2 (λ3/λ1)0.4 ± 0.020.41 ± 0.020.530 (ns)
R3 (λ2/λ3)1.61 ± 0.121.7 ± 0.070.279 (ns)
Anterior commissureFractional anisotropy0.48 ± 0.020.50 ± 0.080.550 (ns)
R1 (λ2/λ1)0.5 ± 0.020.63 ± 0.580.004
R2 (λ3/λ1)0.38 ± 0.020.33 ± 0.090.184
R3 (λ2/λ3)1.33 ± 0.081.85 ± 0.450.052 (ns)
Internal capsule and cerebral peduncleFractional anisotropy0.62 ± 0.040.62 ± 0.021.000 (ns)
R1 (λ2/λ1)0.38 ± 0.040.51 ± 0.030.004
R2 (λ3/λ1)0.26 ± 0.030.21 ± 0.020.028
R3 (λ2/λ3)1.47 ± 0.042.6 ± 0.25< 0.001
Optic tractFractional anisotropy0.61 ± 0.040.63 ± 0.050.641 (ns)
R1 (λ2/λ1)0.39 ± 0.030.47 ± 0.040.013
R2 (λ3/λ1)0.27 ± 0.050.22 ± 0.050.204 (ns)
R3 (λ2/λ3)1.46 ± 0.172.37 ± 0.510.018
CortexFractional anisotropy0.22 ± 0.070.25 ± 0.030.436 (ns)
R1 (λ2/λ1)0.79 ± 0.090.79 ± 0.020.897 (ns)
R2 (λ3/λ1)0.66 ± 0.090.61 ± 0.040.322 (ns)
R3 (λ2/λ3)1.20 ± 0.041.30 ± 0.060.035
HippocampusFractional anisotropy0.18 ± 0.050.23 ± 0.290.125 (ns)
R1 (λ2/λ1)0.83 ± 0.070.8 ± 0.020.455 (ns)
R2 (λ3/λ1)0.7 ± 0.060.62 ± 0.040.087 (ns)
R3 (λ2/λ3)1.18 ± 0.171.29 ± 0.040.002
StriatumFractional anisotropy0.27 ± 0.030.3 ± 0.060.320 (ns)
R1 (λ2/λ1)0.72 ± 0.040.75 ± 0.040.259 (ns)
R2 (λ3/λ1)0.61 ± 0.030.55 ± 0.070.191 (ns)
R3 (λ2/λ3)1.18 ± 0.021.39 ± 0.110.006

Data are presented as mean ± standard deviation (× 10−4 mm2/s)

DTI diffusion tensor imaging, ns not significant

Diffusivities of in vivo and ex vivo regions of interest using the surface coil and one excitation Data are presented as mean ± standard deviation (× 10− 4 mm2/s) ***p < 0.001 Reduction of diffusivities in selected regions of interest after fixation, using the surface coil and one excitation Data are presented as mean ± standard deviation (× 10− 4 mm2/s) Dimensionless DTI parameters of in vivo and ex vivo regions of interest using the surface coil and one excitation Data are presented as mean ± standard deviation (× 10−4 mm2/s) DTI diffusion tensor imaging, ns not significant

Comparisons of ex vivo DTI parameters under different scan conditions

Figure 2 and Table 4 show the comparisons of ex vivo diffusivities after using different coils and number of excitations. There were significant differences in the MD of major brain structures using the surface coil compared to the volume coil for four excitations. There were significant differences in the MD of major brain structures with one compared to four excitations for both coils. Also there were significant differences between the AD of major brain structures obtained using the surface coil and those obtained using the volume coil, and differences between brain structures imaged with one compared to four excitations. The RD of major brain ROIs with one excitation was significantly different from that with four excitations.
Fig. 2

Comparisons of ex vivo diffusivities using the surface coil and the volume coil, and using one and four excitations. Most diffusivities in major brain structures differed when using different coils and numbers of excitations. AC, anterior commissure; AD, axial diffusivity; CC, corpus callosum; CT, cortex; EC, external capsule; HP, hippocampus; ICCP, internal capsule and cerebral peduncle; MD, mean diffusivity; ns, not significant; OT, optic tract; RD, radial diffusivity; ST, striatum; SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations. *p < 0.05; **p < 0.01; ***p < 0.001

Table 4

Comparisons of DTI parameters and SNR using different coils and different numbers of excitations

StructuresComparisonsFractional anisotropyMean diffusivityAxial diffusivityRadial diffusivityR1 (λ2/λ1)R2 (λ3/λ1)R3 (λ2/λ3)SNR
Corpus callosumSC-1 versus VC-10.0160.067 (ns)0.0160.354 (ns)0.109 (ns)0.0030.0240.020
SC-1 versus SC-40.0030.0010.0010.0010.255 (ns)0.0020.0040.001
VC-1 versus VC-40.259 (ns)0.0100.0100.0420.536 (ns)0.0170.088 (ns)< 0.001
VC-4 versus SC-40.191 (ns)< 0.001< 0.001< 0.0010.462 (ns)0.111 (ns)1.000 (ns)0.034
External capsuleSC-1 versus VC-1< 0.0010.050 (ns)0.0070.262 (ns)< 0.001< 0.0010.0040.004
SC-1 versus SC-40.001< 0.0010.001< 0.0010.0010.0020.0100.001
VC-1 versus VC-40.151 (ns)0.0080.0170.0080.129 (ns)0.235 (ns)0.507 (ns)< 0.001
VC-4 versus SC-40.0480.0010.0010.0020.0040.0480.503 (ns)0.007
Anterior commissureSC-1 versus VC-10.0090.365 (ns)0.742 (ns)0.194 (ns)0.724 (ns)0.0080.064 (ns)0.001
SC-1 versus SC-40.009< 0.001< 0.001< 0.0010.784 (ns)0.0040.0470.004
VC-1 versus VC-40.328 (ns)0.115 (ns)0.0220.361 (ns)0.118 (ns)0.524 (ns)0.222 (ns)< 0.001
VC-4 versus SC-40.882 (ns)0.0180.0460.066 (ns)0.444 (ns)0.445 (ns)0.080 (ns)0.001
Internal capsule and cerebral peduncleSC-1 versus VC-10.0300.507 (ns)0.538 (ns)0.510 (ns)0.0110.0010.001< 0.001
SC-1 versus SC-40.566 (ns)0.0030.0020.0230.0050.0260.0010.001
VC-1 versus VC-40.0480.0090.0470.0210.601 (ns)0.0130.020< 0.001
VC-4 versus SC-40.0020.059 (ns)0.0130.779 (ns)0.391 (ns)0.0010.010< 0.001
Optic tractSC-1 versus VC-10.343 (ns)0.851 (ns)0.328 (ns)0.815 (ns)0.928 (ns)0.203 (ns)0.159 (ns)< 0.001
SC-1 versus SC-40.238 (ns)0.0150.0010.068 (ns)0.812 (ns)0.126 (ns)0.0280.002
VC-1 versus VC-40.545 (ns)0.073 (ns)0.0260.151 (ns)0.823 (ns)0.413 (ns)0.228 (ns)< 0.001
VC-4 versus SC-40.150 (ns)0.090 (ns)0.0320.578 (ns)0.688 (ns)0.0280.021< 0.001
CortexSC-1 versus VC-10.0110.055 (ns)0.0280.242 (ns)0.122 (ns)0.0110.0050.012
SC-1 versus SC-40.0010.0010.007< 0.0010.0040.0010.0030.001
VC-1 versus VC-40.0010.0120.0420.055 (ns)0.771 (ns)0.534 (ns)0.829 (ns)< 0.001
VC-4 versus SC-40.060 (ns)0.0010.0010.0020.363 (ns)0.256 (ns)0.504 (ns)0.008
HippocampusSC-1 versus VC-10.0240.054 (ns)0.0200.103 (ns)0.129 (ns)0.0210.0010.008
SC-1 versus SC-40.001< 0.0010.0010.721 (ns)0.0060.0020.0020.001
VC-1 versus VC-40.0110.0070.0080.0070.287 (ns)0.065 ns)0.002< 0.001
VC-4 versus SC-40.328 (ns)0.0050.0030.814 (ns)0.691 (ns)0.363 (ns)0.272 (ns)0.013
StriatumSC-1 versus VC-10.0080.107 (ns)0.0040.948 (ns)0.0110.0060.0080.002
SC-1 versus SC-40.003< 0.0010.001< 0.0010.0060.0020.0040.002
VC-1 versus VC-40.091 (ns)0.0080.0140.0070.259 (ns)0.0480.001< 0.001
VC-4 versus SC-40.0050.0060.0040.0100.0070.0090.0110.003

Data are p values

SNR signal-to-noise ratio, SC-1 surface coil and one excitation, SC-4 surface coil and four excitations, VC-1 volume coil and one excitation, VC-4 volume coil and four excitations

Comparisons of ex vivo diffusivities using the surface coil and the volume coil, and using one and four excitations. Most diffusivities in major brain structures differed when using different coils and numbers of excitations. AC, anterior commissure; AD, axial diffusivity; CC, corpus callosum; CT, cortex; EC, external capsule; HP, hippocampus; ICCP, internal capsule and cerebral peduncle; MD, mean diffusivity; ns, not significant; OT, optic tract; RD, radial diffusivity; ST, striatum; SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations. *p < 0.05; **p < 0.01; ***p < 0.001 Comparisons of DTI parameters and SNR using different coils and different numbers of excitations Data are p values SNR signal-to-noise ratio, SC-1 surface coil and one excitation, SC-4 surface coil and four excitations, VC-1 volume coil and one excitation, VC-4 volume coil and four excitations Figure 3 and Table 4 show the comparisons of ex vivo dimensionless parameters after using different coils and numbers of excitations. The FA of major brain ROIs using the surface coil was significantly different from that using the volume coil for one excitation. For the surface coil, there were significant differences in the FA of major brain structures using one compared to four excitations. There were significant differences in R1 using one compared to four excitations using the surface coil. There were significant differences in R2 of major brain structures using one compared to four excitations using the surface coil. The R2 of major brain ROIs using the surface coil was significantly different from that using the volume coil for one excitation. The R3 of major brain ROIs using the surface coil was significantly different from that using the volume coil for one excitation. There were significant differences in R3 of brain structures using one compared to four excitations and the surface coil.
Fig. 3

Comparisons of ex vivo dimensionless diffusion tensor imaging (DTI) parameters using the surface coil and the volume coil, and using one and four excitations. Most dimensionless DTI parameters in major brain structures differed using different coils and numbers of excitations. AC, anterior commissure; AD, axial diffusivity; CC, corpus callosum; CT, cortex; EC, external capsule; HP, hippocampus; ICCP, internal capsule and cerebral peduncle; MD, mean diffusivity; ns, not significant; OT, optic tract; RD, radial diffusivity; ST, striatum; SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations. *p < 0.05; **p < 0.01; ***p < 0.001

Comparisons of ex vivo dimensionless diffusion tensor imaging (DTI) parameters using the surface coil and the volume coil, and using one and four excitations. Most dimensionless DTI parameters in major brain structures differed using different coils and numbers of excitations. AC, anterior commissure; AD, axial diffusivity; CC, corpus callosum; CT, cortex; EC, external capsule; HP, hippocampus; ICCP, internal capsule and cerebral peduncle; MD, mean diffusivity; ns, not significant; OT, optic tract; RD, radial diffusivity; ST, striatum; SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations. *p < 0.05; **p < 0.01; ***p < 0.001 There were significant differences in the SNR of brain structures using the surface coil compared to the volume coil, and with one compared to four excitations (Fig. 4 and Table 4). With the same coil, the SNRs of all the selected ROIs were significantly greater with four excitations than with one excitation. The SNR of brain structures was significantly greater using the volume coil than using the surface coil when the same number of excitations was selected.
Fig. 4

Comparisons of signal-to-noise (SNR) using the surface coil and the volume coil, and using one and four excitations. There were significant differences in the SNR of brain structures using the surface coil compared to the volume coil, and using one compared to four excitations. AC, anterior commissure; AD, axial diffusivity; CC, corpus callosum; CT, cortex; EC, external capsule; HP, hippocampus; ICCP, internal capsule and cerebral peduncle; MD, mean diffusivity; ns, not significant; OT, optic tract; RD, radial diffusivity; ST, striatum; SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations. *p < 0.05; **p < 0.01; ***p < 0.001

Comparisons of signal-to-noise (SNR) using the surface coil and the volume coil, and using one and four excitations. There were significant differences in the SNR of brain structures using the surface coil compared to the volume coil, and using one compared to four excitations. AC, anterior commissure; AD, axial diffusivity; CC, corpus callosum; CT, cortex; EC, external capsule; HP, hippocampus; ICCP, internal capsule and cerebral peduncle; MD, mean diffusivity; ns, not significant; OT, optic tract; RD, radial diffusivity; ST, striatum; SC-1, surface coil and one excitation; SC-4, surface coil and four excitations; VC-1, volume coil and one excitation; VC-4, volume coil and four excitations. *p < 0.05; **p < 0.01; ***p < 0.001

Discussion

In terms of the degree of WM and GM, our study showed that the FA of WM integrity was greater than that of GM integrity, in agreement with previous research [16, 20]. Interestingly, the results for the RD, R1, and R2 were opposite to those for the FA, and the AD in WM integrity and GM integrity was similar, suggesting that the RD constitutes the main difference in diffusion between WM integrity and GM integrity. The diffusivities of brain WM ROIs and GM ROIs decreased after fixation, which is consistent with previous studies [13, 14, 16]. The principle of fixation is related to the formation of cross-links between proteins or between proteins and nucleic acids, which involves hydroxymethylene bridges and coordinate bonds for calcium ions, altering the three-dimensional structure of proteins [21-24]. Changes in the molecular structure may affect the molecular diffusivities. Tissue shrinkage after fixation may also contribute to diffusivity alterations [25-27]. Fixation processes and fixatives may also affect the change in tissue property [20, 28]. Additionally, previous work has found that diffusion is associated with temperature [29-32]. A 2.4% alteration in water diffusion per degree has been determined [31]. The temperature of the magnetic resonance room is 20 °C, whereas the rat body temperature is 37 °C. Furthermore, magnetic resonance tissue characteristics including T1 and T2 relaxations have been proved to tend to decrease after fixation [33-36]. The present study demonstrated that WM diffusivities decreased more than GM diffusivities, which is in accordance with the results of the previous investigations [13, 14]. However, what causes this diversified reduction in the diffusivity of WM and GM remains to be investigated. McGrath et al. [37] have confirmed the different effects of fixation on different tissues. Therefore, the different components of WM and GM may also cause differences in the reduction of diffusivity [13]. For dimensionless DTI parameters, we observed a significant difference in vivo compared to ex vivo only in R3, which may be related to the non-proportional reduction of λ2 and λ3. A better understanding of the details of diffusion change in the microstructure in different directions may be promoted by diffusion kurtosis imaging or multi compartment models [38-41]. In terms of FA, the current study found that anisotropies of the major brain ROIs were similar in the live and in the fixed brain, in agreement with previous investigations [13-15]. There are several limitations in this study. First, there were no in vivo brain data obtained using the volume coil and four excitations, due to the compromised volume coil size and the scanning duration. Second, a slice thickness of 1 mm is probably too thick for ex vivo scanning. Given the weak tolerance of the scanning duration in experimental models, we chose 1 mm to compare in vivo and ex vivo DTI data. Third, it is difficult to observe the histological appearance of the brain both in vivo and ex vivo. In summary, we observed significant effects of the fixation, coil, and number of excitations on major DTI parameters and the SNR of magnetic resonance studies of WM and GM in a rat model imaged at 7.0 T. As a consequence, we suggest that the fixation, coil, and number of excitations should be taken into account in clinical and experimental DTI brain studies.
  40 in total

1.  Diffusion tensor imaging in fixed brain tissue at 7.0 T.

Authors:  David N Guilfoyle; Joseph A Helpern; Kelvin O Lim
Journal:  NMR Biomed       Date:  2003-04       Impact factor: 4.044

2.  Quasi-static magnetic resonance elastography at 7 T to measure the effect of pathology before and after fixation on tissue biomechanical properties.

Authors:  Deirdre M McGrath; Warren D Foltz; Adil Al-Mayah; Carolyn J Niu; Kristy K Brock
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

3.  Three-dimensional strain fields in human brain resulting from formalin fixation.

Authors:  Georg Schulz; Hendrikus J A Crooijmans; Marco Germann; Klaus Scheffler; Magdalena Müller-Gerbl; Bert Müller
Journal:  J Neurosci Methods       Date:  2011-08-25       Impact factor: 2.390

4.  The shrinkage of the human brain stem during formalin fixation and embedding in paraffin.

Authors:  R Quester; R Schröder
Journal:  J Neurosci Methods       Date:  1997-07-18       Impact factor: 2.390

5.  Diffusion tensor imaging for outcome prediction in mild traumatic brain injury: a TRACK-TBI study.

Authors:  Esther L Yuh; Shelly R Cooper; Pratik Mukherjee; John K Yue; Hester F Lingsma; Wayne A Gordon; Alex B Valadka; David O Okonkwo; David M Schnyer; Mary J Vassar; Andrew I R Maas; Geoffrey T Manley
Journal:  J Neurotrauma       Date:  2014-07-09       Impact factor: 5.269

6.  Simultaneous measurements of diffusion and transverse relaxation in exercising skeletal muscle.

Authors:  D Morvan; A Leroy-Willig
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

7.  Assessment of murine brain tissue shrinkage caused by different histological fixatives using magnetic resonance and computed tomography imaging.

Authors:  Hans F Wehrl; Ilja Bezrukov; Stefan Wiehr; Mareike Lehnhoff; Kerstin Fuchs; Julia G Mannheim; Leticia Quintanilla-Martinez; Ursula Kohlhofer; Manfred Kneilling; Bernd J Pichler; Alexander W Sauter
Journal:  Histol Histopathol       Date:  2014-12-11       Impact factor: 2.303

8.  The fornix provides multiple biomarkers to characterize circuit disruption in a mouse model of Alzheimer's disease.

Authors:  Alexandra Badea; Lauren Kane; Robert J Anderson; Yi Qi; Mark Foster; Gary P Cofer; Neil Medvitz; Anne F Buckley; Andreas K Badea; William C Wetsel; Carol A Colton
Journal:  Neuroimage       Date:  2016-08-10       Impact factor: 6.556

9.  Temperature dependent change of apparent diffusion coefficient of water in normal and ischemic brain of rats.

Authors:  Y Hasegawa; L L Latour; C H Sotak; B J Dardzinski; M Fisher
Journal:  J Cereb Blood Flow Metab       Date:  1994-05       Impact factor: 6.200

10.  In vivo high-resolution diffusion tensor imaging of the mouse brain.

Authors:  Dan Wu; Jiadi Xu; Michael T McMahon; Peter C M van Zijl; Susumu Mori; Frances J Northington; Jiangyang Zhang
Journal:  Neuroimage       Date:  2013-06-12       Impact factor: 6.556

View more
  3 in total

1.  Microstructural Tissue Changes in a Rat Model of Mild Traumatic Brain Injury.

Authors:  Karthik Chary; Omar Narvaez; Raimo A Salo; Isabel San Martín Molina; Jussi Tohka; Manisha Aggarwal; Olli Gröhn; Alejandra Sierra
Journal:  Front Neurosci       Date:  2021-11-26       Impact factor: 4.677

2.  The orbitofrontal cortex of the sheep. Topography, organization, neurochemistry, digital tensor imaging and comparison with the chimpanzee and human.

Authors:  Tommaso Gerussi; Jean-Marie Graïc; Annamaria Grandis; Antonella Peruffo; Bruno Cozzi
Journal:  Brain Struct Funct       Date:  2022-03-26       Impact factor: 3.748

3.  7-T MRI of explanted liver and ex-vivo pancreatic specimens: prospective study protocol of radiological-pathological correlation feasibility (the EXLIPSE project).

Authors:  Rosa Cervelli; Matteo Cencini; Guido Buonincontri; Francesco Campana; Andrea Cacciato Insilla; Giacomo Aringhieri; Paolo De Simone; Ugo Boggi; Daniela Campani; Michela Tosetti; Laura Crocetti
Journal:  Eur Radiol Exp       Date:  2020-10-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.