BACKGROUND: Standardization for reporting medical outcomes facilitates clinical study comparisons and has a fundamental role on research reproducibility. In this context, we present AstigMATIC, a free standalone application for automated standardized astigmatism vector analyses in corneal and intraocular refractive surgeries. AstigMATIC uses a simple graphical user interface (GUI) and allows the simultaneous display and analysis of astigmatism magnitude and axis.Entities:
Keywords: Alpins Methods; Astigmatism vector analysis; Correction index; Difference vector; Surgically-induced astigmatism vector; Target-induced astigmatism vector
Mesh:
Year: 2018 PMID: 30241474 PMCID: PMC6151063 DOI: 10.1186/s12886-018-0920-1
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Data file format example
| Eye | Preop Magnitude | Preop Axis | Postop Magnitude | Postop Axis | |
|---|---|---|---|---|---|
| Data point 1 | OD | 0.25 | 007 | 0 | 0 |
| Data point 2 | OS | 0.75 | 88 | −0.25 | a |
| Data point 3 | OD | −2.00b | 90 | 0 | 0 |
| … | … | … | … | … | … |
| Data point N | OS | −1.00b | 180 | 0 | 0 |
Example of the Excel data file format that is read by AstigMATIC to generate the four standard astigmatism vector graphs. Note that the first column and row should not be included in the actual data file. Please use the point decimal notation and not comma. Three data file samples are provided at http://www.lasikmd.com/media/astigmatic/
a This row will automatically be discarded given the missing value
b This row will automatically be converted from -ve cylinder to +ve cylinder format. For example, − 2.00 × 90 will be converted to + 2.00 × 180 and − 1.00 × 180 to + 1.00 × 90
Fig. 1Flow chart of the AstigMATIC workflow. a-b Upon starting the application, raw astigmatism data must first be imported. c The user is invited to select which graphs to include in the analysis. d The selected graphs are then generated. e The user is invited to visualize, save or close the figures. f By selecting “save”, the figures are automatically saved as TIFF images in a folder with the same name and location as the original Excel data file
Fig. 2Examples of the four vector graphs that are generated by AstigMATIC from the pre- and post-operative cylinder magnitude and axis in within-the-rule (WTR) astigmatism eyes (a), against-the-rule (ATR) astigmatism eyes (b), and oblique astigmatism eyes (c). The TIA and SIA data points of WTR, ATR and oblique cases are located in the red, blue and white regions of the graphs, respectively. The red diamonds indicate the vector mean position. The vector mean values are displayed in the call-out boxes along with the arithmetic means or geometrical mean. Each individual vectorial point is plotted as a black line ending by a blue circle marker