Literature DB >> 30232734

Comparing the Effects of Additives on Protein Analysis Between Desorption Electrospray (DESI) and Electrospray Ionization (ESI).

Elahe Honarvar1, Andre R Venter2.   

Abstract

It is frequently said that DESI-MS follows a similar ionization mechanism as ESI because of similarities usually observed in their respective mass spectra. However, practical use of DESI-MS for protein analysis is limited to proteins with lower molecular weights (< 25 kDa) due to a mass-dependent loss in signal intensity. Here we investigated commonly used volatile acids and their ammonium salt buffers for DESI-MS analysis of protein. We noticed that, surprisingly, some additives influence the analysis differently in DESI compared to ESI. Improved signal intensities with both DESI and ESI were obtained when acetic and formic acid were added into aqueous methanol spray solvents with both DESI and ESI. On the other hand, while with ESI the addition of ammonium salts into spray solutions strongly reduced both signal and S/N, with DESI signal intensities and S/N were improved dramatically. Ammonium bicarbonate when used with DESI reduced the total amount of adduction and delivered excellent signal-to-noise ratios with high intensity; however, it also denatures protein. When native state protein mass spectra are preferred, ammonium acetate would also deliver reasonable adduct removal and improved S/N. The amount of total adduction of individual adducting species and of all species could not be correlated with differences in either solutions pH values or with proton affinities of the anions. An obvious difference between DESI and ESI mass spectrometry is the effects of protein solubility during droplet pickup (desorption), but differences in the sizes, velocities, and composition of ionizing droplets were also discussed as important factors. Graphical Abstract ᅟ.

Entities:  

Keywords:  Ambient ionization; Ammonium bicarbonate; Chymotrypsinogen; Cytochrome c; DESI; Desorption electrospray ionization; Electrospray; Ionization; Myoglobin; Protein

Mesh:

Substances:

Year:  2018        PMID: 30232734     DOI: 10.1007/s13361-018-2058-z

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  50 in total

1.  Buffer loading for counteracting metal salt-induced signal suppression in electrospray ionization.

Authors:  Anthony T Iavarone; Osita A Udekwu; Evan R Williams
Journal:  Anal Chem       Date:  2004-07-15       Impact factor: 6.986

Review 2.  Desorption electrospray ionization and other ambient ionization methods: current progress and preview.

Authors:  Demian R Ifa; Chunping Wu; Zheng Ouyang; R Graham Cooks
Journal:  Analyst       Date:  2010-03-02       Impact factor: 4.616

3.  Desorption electrospray ionization in a small pressure-tight enclosure.

Authors:  Andre Venter; R Graham Cooks
Journal:  Anal Chem       Date:  2007-07-14       Impact factor: 6.986

4.  Electrospray wings for molecular elephants (Nobel lecture).

Authors:  John B Fenn
Journal:  Angew Chem Int Ed Engl       Date:  2003-08-25       Impact factor: 15.336

5.  The inverse and direct Hofmeister series for lysozyme.

Authors:  Yanjie Zhang; Paul S Cremer
Journal:  Proc Natl Acad Sci U S A       Date:  2009-08-21       Impact factor: 11.205

6.  Ion-ion and ion-molecule reactions at the surface of proteins produced by nanospray. Information on the number of acidic residues and control of the number of ionized acidic and basic residues.

Authors:  Udo H Verkerk; Paul Kebarle
Journal:  J Am Soc Mass Spectrom       Date:  2005-08       Impact factor: 3.109

7.  Reactive DESI-MS imaging of biological tissues with dicationic ion-pairing compounds.

Authors:  Dragos Lostun; Consuelo J Perez; Peter Licence; David A Barrett; Demian R Ifa
Journal:  Anal Chem       Date:  2015-02-24       Impact factor: 6.986

8.  Electrospray droplet exposure to polar vapors: delayed desolvation of protein complexes.

Authors:  J Corinne DeMuth; Jiexun Bu; Scott A McLuckey
Journal:  Rapid Commun Mass Spectrom       Date:  2015-05-30       Impact factor: 2.419

9.  Solution-phase chelators for suppressing nonspecific protein-metal interactions in electrospray mass spectrometry.

Authors:  Jingxi Pan; Kun Xu; Xiaoda Yang; Wing-Yiu Choy; Lars Konermann
Journal:  Anal Chem       Date:  2009-06-15       Impact factor: 6.986

10.  Anions in electrothermal supercharging of proteins with electrospray ionization follow a reverse Hofmeister series.

Authors:  Catherine A Cassou; Evan R Williams
Journal:  Anal Chem       Date:  2014-01-24       Impact factor: 6.986

View more
  4 in total

1.  Addition of Serine Enhances Protein Analysis by DESI-MS.

Authors:  Roshan Javanshad; Elahe Honarvar; Andre R Venter
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-15       Impact factor: 3.109

2.  Identification of milk from different animal and plant sources by desorption electrospray ionisation high-resolution mass spectrometry (DESI-MS).

Authors:  Yunhe Hong; Nicholas Birse; Brian Quinn; Holly Montgomery; Di Wu; Gonçalo Rosas da Silva; Saskia M van Ruth; Christopher T Elliott
Journal:  NPJ Sci Food       Date:  2022-02-11

3.  Native Mass Spectrometry of Iron-Sulfur Proteins.

Authors:  Jason C Crack; Nick E Le Brun
Journal:  Methods Mol Biol       Date:  2021

4.  Spatially resolved analysis of Pseudomonas aeruginosa biofilm proteomes measured by laser ablation sample transfer.

Authors:  Aruni Chathurya Pulukkody; Yeni P Yung; Fabrizio Donnarumma; Kermit K Murray; Ross P Carlson; Luke Hanley
Journal:  PLoS One       Date:  2021-07-22       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.