| Literature DB >> 30231854 |
Sweet Ping Ng1, Houda Bahig2, Jihong Wang3, Carlos E Cardenas3, Anthony Lucci4, Carolyn S Hall4, Salyna Meas4, Vanessa N Sarli4, Ying Yuan5, Diana L Urbauer5, Yao Ding3, Shane Ikner2, Vi Dinh2, Baher A Elgohari2, Jason M Johnson6, Heath D Skinner2, G Brandon Gunn2, Adam S Garden2, Jack Phan2, David I Rosenthal2, William H Morrison2, Steven J Frank2, Katherine A Hutcheson7, Abdallah S R Mohamed2, Stephen Y Lai7, Renata Ferrarotto8, Michael P MacManus9, Clifton D Fuller2.
Abstract
BACKGROUND: Magnetic resonance imaging (MRI) has improved capacity to visualize tumor and soft tissue involvement in head and neck cancers. Using advanced MRI, we can interrogate cell density using diffusion weighted imaging, a quantitative imaging that can be used during radiotherapy, when diffuse inflammatory reaction precludes PET imaging, and can assist with target delineation as well. Correlation of circulating tumor cells (CTCs) measurements with 3D quantitative tumor characterization could potentially allow selective, patient-specific response-adapted escalation or de-escalation of local therapy, and improve the therapeutic ratio, curing the greatest number of patients with the least toxicity.Entities:
Keywords: Biomarker; Circulating tumor cells; Head and neck cancer; Magnetic resonance imaging
Mesh:
Substances:
Year: 2018 PMID: 30231854 PMCID: PMC6148797 DOI: 10.1186/s12885-018-4808-5
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.638
Fig. 1Research protocol workflow. * If receiving induction chemotherapy, first sample of blood collected pre-chemotherapy
MRI sequences to be obtained during the study
| Parameter | T1 | T2 | DWI (BLADE) |
|---|---|---|---|
| Slice Orientation | Axial | Axial | Axial |
| Field of View (mm) | 256 | 256 | 256 |
| Voxel Size (mm) | 1 × 1 × 2 | 1 × 1 × 2 | 2 × 2 × 4 |
| Recon Voxel Size (mm) | 0.5 × 0.5 × 1 | 0.5 × 0.5 × 2 | 2 × 2 × 4 |
| Parallel Imaging | No | Yes; Factor 2 | No |
| Slice number | 240 | 120 | 25 |
| Fold-over Direction | AP | AP | N/A |
| Slice Oversampling | 100% | No | No |
| Shim | Auto | Auto | Auto |
| Scan Mode | 3D | M2D | M2D |
| Technique | GRE | SE | BLADE |
| Fast Imaging Mode | No | TSE | TSE and EPI |
| Echoes | 1 | 1 | 1 |
| Flip Angle (deg) | 20 | 90 | 90 |
| TR (ms) | 7.38 | 4800 | 5400 |
| Echo Time (ms) | 4.77 | 80 | 50 |
| Fat Suppression | No | No | Yes |
| b-values (s/mm2) | N/A | N/A | 0, 800 |
| NEX | 1 | 1 | 8 |
| Geometry Correction | 3D | 2D | No |
| Echo Train Length | 1 | 15 | 15 |
| Percent Sampling (%) | 80 | 90 | 100 |
| Pixel Bandwidth (Hz) | 400 | 300 | 1220 |
| Scan Duration (min) | 6:05 | 4:48 | 7:08 |
Fig. 2Research schema
Summary of pre-, during and post evaluations during the study
| Baseline | Weekly treatment visits | Follow Up (2–3 months) | |
|---|---|---|---|
| Physical examination with or without nasoendoscopy | X | X | X |
| Weight and BMI | X | X | X |
| Complete blood count with differential | |||
| - Hemoglobin | |||
| - Neutrophil count | |||
| - Platelet count | |||
| - Monocyte count | X | X | X |
| Basic Metabolic Panel | |||
| - Electrolytes | |||
| - Liver function tests | |||
| - Albumin | |||
| - ESR | |||
| - CRP | X | X | X |
| Blood biomarker collection: | |||
| - 10 ml CellSave tube | |||
| - 2 × 10 ml EDTA tubes | X | X | X |
| Pregnancy test (female of childbearing age) | X | ||
| Contrast CT head and neck | X | X | |
| 18F-FDG PET/CT | X | X | |
| MRI of the head and neck | X | X | X |