Jiajun Zeng1, Huanhua Xu2,3, Yu Cai4, Yan Xuan5, Jia Liu6, Yue Gao7, Qingxian Luan8.
Abstract
(-)-Epigallocatechin gallate (EGCG), is the main catechin found in green tea, and has several beneficial effects. This study investigated the stability of EGCG aqueous solution under different stored and ultrasonic conditions to determine whether it can be used with an ultrasonic dental scaler to treat periodontal infection. Four concentrations (0.05, 0.1, 0.15, 2 mg/mL) of EGCG aqueous solution were prepared and stored under four different conditions (A: Exposed to neither sunlight nor air, B: Exposed to sunlight, but not air, C: Not exposed to sunlight, but air, D: Exposed to sunlight and air) for two days. The degradation rate of EGCG was measured by high performance liquid chromatography (HPLC). On the other hand, an ultrasonic dental scaler was used to atomize the EGCG solution under four different conditions (a: Exposed to neither air nor sunlight, b: Not exposed to air, but sunlight, c: Not exposed to sunlight, but air, d: Exposed to air and sunlight), the degradation of EGCG was measured by HPLC. We found that the stability of EGCG was concentration-dependent in water at room temperature. Both sunlight and oxygen influenced the stability of EGCG, and oxygen had a more pronounced effect on stability of EGCG than sunlight. The most important conclusion was that the ultrasound may accelerate the degradation of EGCG due to the presence of oxygen and sunlight, but not because of the ultrasonic vibration. Thus, EGCG aqueous solution has the potential to be used through an ultrasonic dental scaler to treat periodontal infection in the future.Entities:
Keywords: (−)-epigallocatechin gallate (EGCG); degradation; green tea; high performance liquid chromatography (HPLC); oxygen; stability; sunlight; ultrasound
Mesh:
Substances:
Year: 2018 PMID: 30231585 PMCID: PMC6225204 DOI: 10.3390/molecules23092394
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1The chromatogram of the 2.00 mg/mL EGCG aqueous solution (a), the 0.05 mg/mL EGCG aqueous solution stored without sunlight and air at room temperature for 6 h (b).
Standard curve, correlation coefficient, linear ranges and lower limit of quantification (LLOQ) of EGCG in water.
| Analyte | Calibration Curve | R2 | Linear Range (mg/mL) | LLOQ (mg/mL) |
|---|---|---|---|---|
| EGCG | 0.999 | 0.005–2.5 | 0.005 |
Intra-day/inter-day accuracy and precision of EGCG in water.
| Nominal Concentration (mg/mL) | Intra-Day | Inter-Day | ||||
|---|---|---|---|---|---|---|
| Measured Concentration (mg/mL) | RSD (%) | Accuracy (%) | Measured Concentration (mg/mL) | RSD (%) | Accuracy (%) | |
| 0.203 | 0.201 ± 0.003 | 1.73 | 98.88 ± 1.71 | 0.189 ± 0.008 | 4.19 | 93.14 ± 3.90 |
| 2.109 | 2.099 ± 0.040 | 1.93 | 99.51 ± 1.92 | 2.071 ± 0.040 | 1.93 | 99.85 ± 1.90 |
Figure 2Stability of all concentrations of EGCG aqueous solutions under condition (A): exposed to neither sunlight nor air.
Figure 3Stability of all concentrations of EGCG aqueous solutions under condition (D): exposed to sunlight and air.
The residual concentration of EGCG in the EGCG aqueous solution stored with or without sunlight and air for different time periods.
| Initial Concentration (mg/mL) | Condition Name | Sunlight | Oxygen | Time (h) | ||||
|---|---|---|---|---|---|---|---|---|
| 6 h (mg/mL) | 12 h (mg/mL) | 24 h (mg/mL) | 36 h (mg/mL) | 48h (mg/mL) | ||||
| 0.05 | (A) | No | No | 0.038 ± 0.003 | 0.031 ± 0.004 | 0.015 ± 0.001 | 0.015 ± 0.001 | 0.012 ± 0.001 |
| (B) | Yes | No | 0.036 ± 0.006 | 0.027 ± 0.001 | 0.013 ± 0.000 | 0.009 ± 0.001 | 0.008 ± 0.001 | |
| (C) | No | Yes | 0.033 ± 0.009 | 0.020 ± 0.006 | 0.006 ± 0.001 | N | N | |
| (D) | Yes | Yes | 0.032 ± 0.004 | 0.019 ± 0.002 | 0.005 ± 0.001 | N | N | |
| 0.10 | (A) | No | No | 0.100 ± 0.006 | 0.090 ± 0.007 | 0.086 ± 0.005 | 0.070 ± 0.004 | 0.038 ± 0.002 |
| (B) | Yes | No | 0.093 ± 0.005 | 0.088 ± 0.003 | 0.071 ± 0.003 | 0.065 ± 0.003 | 0.028 ± 0.001 | |
| (C) | No | Yes | 0.082 ± 0.004 | 0.074 ± 0.004 | 0.055 ± 0.005 | 0.041 ± 0.002 | N | |
| (D) | Yes | Yes | 0.082 ± 0.009 | 0.068 ± 0.008 | 0.044 ± 0.007 | 0.030 ± 0.004 | N | |
| 0.15 | (A) | No | No | 0.150 ± 0.011 | 0.141 ± 0.004 | 0.135 ± 0.003 | 0.104 ± 0.003 | 0.093 ± 0.006 |
| (B) | Yes | No | 0.136 ± 0.005 | 0.136 ± 0.007 | 0.118 ± 0.004 | 0.089 ± 0.005 | 0.087 ± 0.001 | |
| (C) | No | Yes | 0.128 ± 0.007 | 0.121 ± 0.009 | 0.107 ± 0.002 | 0.072 ± 0.006 | 0.058 ± 0.003 | |
| (D) | Yes | Yes | 0.128 ± 0.010 | 0.109 ± 0.004 | 0.070 ± 0.003 | 0.068 ± 0.010 | 0.029 ± 0.002 | |
| 2.00 | (A) | No | No | 2.015 ± 0.031 | 2.000 ± 0.020 | 2.000 ± 0.040 | 1.998 ± 0.025 | 1.997 ± 0.031 |
| (B) | Yes | No | 2.004 ± 0.041 | 2.001 ± 0.039 | 2.000 ± 0.028 | 1.999 ± 0.050 | 1.997 ± 0.056 | |
| (C) | No | Yes | 2.003 ± 0.024 | 2.002 ± 0.018 | 2.000 ± 0.022 | 1.997 ± 0.046 | 1.991 ± 0.039 | |
| (D) | Yes | Yes | 1.947 ± 0.010 | 1.900 ± 0.028 | 1.893 ± 0.032 | 1.806 ± 0.036 | 1.786 ± 0.060 | |
N: not detected.
Pearson correlation coefficient between the percentage of the residual concentration of EGCG and effect factors.
| Effect Factor | Correlation Coefficient | |
|---|---|---|
| Sunlight | –0.091 | 0.425 |
| Oxygen | –0.266 | 0.017 * |
| Time | –0.522 | 0.000 * |
| Concentration | 0.706 | 0.000 * |
* p-value < 0.05. Correlation coefficient: If the correlation coefficient is below 0, it means that the factor has a negative effect on the stabilization of EGCG; if the correlation coefficient is over 0, it means that the factor has a positive effect on the stabilization of EGCG.
EGCG degradation in EGCG solution atomized by ultrasonic scaler without oxygen: A between-group analysis.
| Initial Concentration (mg/mL) | Sunlight | Oxygen | Test Group Concentration (mg/mL) | Control Group Concentration (mg/mL) | |
|---|---|---|---|---|---|
| 0.05 | No | No | 0.047 ± 0.002 | 0.052 ± 0.002 | 0.057 |
| Yes | No | 0.046 ± 0.005 | 0.224 | ||
| 0.10 | No | No | 0.099 ± 0.003 | 0.099 ± 0.002 | 0.803 |
| Yes | No | 0.099 ± 0.009 | 0.990 | ||
| 0.15 | No | No | 0.151 ± 0.002 | 0.149 ± 0.002 | 0.230 |
| Yes | No | 0.150 ± 0.001 | 0.157 | ||
| 2.00 | No | No | 2.010 ± 0.018 | 2.003 ± 0.040 | 0.592 |
| Yes | No | 2.005 ± 0.014 | 0.864 |
The residual concentration of EGCG in the EGCG solution atomized by an ultrasonic scaler with oxygen: intra-group and between group analysis.
| Initial Concentration (mg/mL) | Sunlight | Oxygen | Test Group Concentration (mg/mL) | Intra-Group | Control Group Concentration (mg/mL) | Between Group |
|---|---|---|---|---|---|---|
| 0.05 | No | Yes | 0.036 ± 0.001 | 0.010* | 0.052 ± 0.002 | 0.001 * |
| Yes | Yes | 0.033 ± 0.001 | <0.001 * | |||
| 0.10 | No | Yes | 0.098 ± 0.009 | 0.484 | 0.099 ± 0.002 | 0.879 |
| Yes | Yes | 0.084 ± 0.005 | 0.028 * | |||
| 0.15 | No | Yes | 0.146 ± 0.002 | 0.053 | 0.099 ± 0.002 | 0.117 |
| Yes | Yes | 0.138 ± 0.004 | 0.040 * | |||
| 2.00 | No | Yes | 1.997 ± 0.049 | 0.882 | 2.003 ± 0.040 | 0.875 |
| Yes | Yes | 1.944 ± 0.032 | 0.094 |
* p-value < 0.05.