David L Buckley1. 1. Biomedical Imaging, University of Leeds, Leeds, United Kingdom.
Abstract
PURPOSE: To test the ability of shutter-speed dynamic contrast-enhanced (DCE) MRI to estimate water exchange (WX) using simulations and assess its performance in clinical case studies of malignant and benign breast tumors. METHODS: Data were simulated using a 1-compartment tracer kinetic (TK) model combined with a 2-pool WX model (2PX) and with a 2-compartment TK model. Typical DCE-MRI acquisition parameters were used with both WX-sensitive (8°) and -insensitive (25°) flip angles. Clinical data were obtained from patients with malignant and benign breast tumors. Data were fitted using a 2-compartment TK model and a 1-compartment TK model combined with 4 WX models: fast exchange limit (FXL), no exchange, 2PX, and shutter-speed. RESULTS: Fits to the 1-compartment simulated data were excellent, but estimates of WX obtained using the 2PX and shutter-speed models were poor. One-compartment TK model fits to the clinical malignant tumor data were bad, except for the shutter-speed model. However, that overestimated TK parameters compared to the best-fit 2-compartment TK model, which predicted a significant blood volume and leaky capillaries (1 tracer compartment is insufficient, 2 are necessary). All models produced excellent fits to the clinical benign tumor data with little variation between parameter estimates (1 tracer compartment is sufficient). CONCLUSION: The 2PX and shutter-speed models were unable to estimate WX from the DCE-MRI data. A good fit to malignant tumor data using the shutter-speed model was not explained by WX, but the choice of an inappropriate TK model leading to distorted parameter estimates.
PURPOSE: To test the ability of shutter-speed dynamic contrast-enhanced (DCE) MRI to estimate water exchange (WX) using simulations and assess its performance in clinical case studies of malignant and benign breast tumors. METHODS: Data were simulated using a 1-compartment tracer kinetic (TK) model combined with a 2-pool WX model (2PX) and with a 2-compartment TK model. Typical DCE-MRI acquisition parameters were used with both WX-sensitive (8°) and -insensitive (25°) flip angles. Clinical data were obtained from patients with malignant and benign breast tumors. Data were fitted using a 2-compartment TK model and a 1-compartment TK model combined with 4 WX models: fast exchange limit (FXL), no exchange, 2PX, and shutter-speed. RESULTS:Fits to the 1-compartment simulated data were excellent, but estimates of WX obtained using the 2PX and shutter-speed models were poor. One-compartment TK model fits to the clinical malignant tumor data were bad, except for the shutter-speed model. However, that overestimated TK parameters compared to the best-fit 2-compartment TK model, which predicted a significant blood volume and leaky capillaries (1 tracer compartment is insufficient, 2 are necessary). All models produced excellent fits to the clinical benign tumor data with little variation between parameter estimates (1 tracer compartment is sufficient). CONCLUSION: The 2PX and shutter-speed models were unable to estimate WX from the DCE-MRI data. A good fit to malignant tumor data using the shutter-speed model was not explained by WX, but the choice of an inappropriate TK model leading to distorted parameter estimates.
Authors: Jin Zhang; Gregory Lemberskiy; Linda Moy; Els Fieremans; Dmitry S Novikov; Sungheon Gene Kim Journal: NMR Biomed Date: 2021-02-25 Impact factor: 4.044
Authors: Marianna Inglese; Katherine L Ordidge; Lesley Honeyfield; Tara D Barwick; Eric O Aboagye; Adam D Waldman; Matthew Grech-Sollars Journal: Neuroradiology Date: 2019-08-07 Impact factor: 2.804