Nobuyuki Takemoto1, Ai Koyanagi2, Masanori Yasuda3, Hiroshi Yamamoto4.
Abstract
BACKGROUND: Fluorescence imaging (FI) is one of the methods to identify sentinel lymph nodes (SLNs). However, the procedure is technically complicated and requires procedural skills, as SLN biopsy must be conducted in dim light conditions. As an improved version of this method, we introduced a combined method (Combined mixed dye and fluorescence; CMF) consisting of indigo carmine blue dye and FI. The direct visualization of SLNs under shadowless surgical light conditions is facilitated by the addition of the blue dye. We compared the SLN detection rates of CMF with that of the indocyanine green (ICG) dye method (ICG-D).Entities:
Keywords: Breast cancer; Fluorescence; Identification rate; Indigo carmine; Indocyanine green (ICG); Sentinel lymph node biopsy
Mesh:
Substances:
Year: 2018 PMID: 30227837 PMCID: PMC6145193 DOI: 10.1186/s12905-018-0646-5
Source DB: PubMed Journal: BMC Womens Health ISSN: 1472-6874 Impact factor: 2.809
Fig. 1CMF method. a Dye injection into the sub-areolar region. b Fluorescence images of the lymphatic channel on the monitor. c Lymphatic channel marking on the skin using Photodynamic Eye images. d Skin incision. e Blue stained SLN. f Fluorescence image of operative field
Baseline characteristics of patients by method of operation
| Characteristic | ICG-D ( | CMF ( | ||
|---|---|---|---|---|
| Age (years) | Mean (SD) | 55.1 (12.6) | 58.1 (12.1) | 0.086 |
| BMI (kg/m2) | Mean (SD) | 22.9 (4.0) | 23.2 (3.9) | 0.482 |
| Tumor location | A | 26 (28.3%) | 26 (23.6%) | 0.731 |
| B | 8 (8.7%) | 13 (11.8%) | ||
| C | 46 (50%) | 53 (48.2%) | ||
| D | 12 (13.0%) | 18 (16.4%) | ||
| T factor | Tis | 4 (4.3%) | 11 (10%) | 0.352 |
| 1 | 72 (78.3%) | 82 (74.5%) | ||
| 2 | 16 (17.4%) | 17 (15.5%) | ||
| N factor | 0 | 76 (82.6%) | 89 (80.9%) | 0.756 |
| 1 | 16 (17.4%) | 21 (19.1%) | ||
| Stage | 0 | 4 (4.3%) | 11 (10%) | 0.264 |
| 1 | 62 (67.4%) | 65 (59.1%) | ||
| 2a | 26 (28.3%) | 34 (30.9%) | ||
| Recurrent cases | 7 (7.6%) | 3 (2.7%) | 0.103 |
Abbreviations: ICG-D Indocyanine green dye method, CMF Combined mixed dye and fluorescence method, SD Standard deviation, BMI Body mass index
Data are n (%) unless otherwise stated
Intra- and post-operative findings of patients by method of operation
| Characteristic | ICG-D ( | CMF ( | ||
|---|---|---|---|---|
| Operation time (min)a | Mean (SD) | 9.27 (4.9) | 6.65 (3.9) | < 0.001 |
| Number of resected SLNs | Mean (range) | 2.21 (1–9) | 1.82 (1–7) | 0.061 |
| Pathological type | Ductal carcinoma in situ | 4 (4.3%) | 11(10.0%) | 0.112 |
| Invasive ductal carcinoma | 83 (90.2%) | 90 (81.8%) | ||
| Invasive lobular carcinoma | 0 (0%) | 4 (3.6%) | ||
| Special type | 5 (5.4%) | 5 (4.5%) | ||
| Estrogen receptor | Positive | 76 (82.6%) | 97 (88.2%) | 0.261 |
| Negative | 16 (17.4%) | 13 (11.8%) | ||
| Progesterone receptor | Positive | 67 (72.8%) | 90 (81.8%) | 0.126 |
| Negative | 25 (27.2%) | 20 (18.2%) | ||
| Herceptine score (HER2) | Positive | 15 (16.3%) | 11 (10%) | 0.163 |
| Negative | 73 (79.3%) | 88 (80%) | ||
| Unknown | 4 (4.3%) | 11 (10%) |
Abbreviations: ICG-D Indocyanine green dye method, CMF Combined mixed dye and fluorescence method, SD Standard deviation, SLN Sentinel lymph node
Data are n (%) unless otherwise stated
aTime to detection of sentinel lymph nodes
Comparison of the identification rate of sentinel lymph nodes between ICG-D and CMF
| Operation method | Identification rate | |
|---|---|---|
| ICG-D | 83.7% (77/92) | 0.003 |
| CMF | 96.4% (106/110) |
Abbreviations: ICG-D Indocyanine green dye method, CMF Combined mixed dye and fluorescence method
Sentinel lymph node detection rates by method of operation stratified by age and body mass index
| Characteristic | Category | ICG-D | CMF | |
|---|---|---|---|---|
| Age (years) | < 60 | 90.6% (48/53) | 94.2% (49/52) | 0.716 |
| ≥60 | 74.3% (29/39) | 98.3% (57/58) | < 0.001 | |
| BMI (kg/m2) | < 25 | 92.7% (63/68) | 98.7% (78/79) | 0.096 |
| ≥25 | 58.3% (14/24) | 90.3% (28/31) | 0.009 |
Abbreviations: ICG-D Indocyanine green dye method, CMF Combined mixed dye and fluorescence method, BMI Body mass index