Literature DB >> 24356798

Comparison of sentinel lymph node biopsy guided by the multimodal method of indocyanine green fluorescence, radioisotope, and blue dye versus the radioisotope method in breast cancer: a randomized controlled trial.

So-Youn Jung1, Seok-Ki Kim, Seok Won Kim, Youngmee Kwon, Eun Sook Lee, Han-Sung Kang, Kyoung Lan Ko, Kyung Hwan Shin, Keun Seok Lee, In Hae Park, Jungsil Ro, Hae Jeong Jeong, Jungnam Joo, Se Hun Kang, Seeyoun Lee.   

Abstract

PURPOSE: This study aimed to evaluate the identification rate and surgery time of sentinel lymph node biopsy (SLNB) by a multimodal method (MMM) using a mixture of indocyanine green (ICG), radioisotope (RI), and blue dye (BD) compared with the RI alone.
METHODS: In this phase II randomized study, 86 patients with clinically node-negative breast cancer were enrolled and received SLNB with either MMM or RI. We compared the identification rate, number of sentinel lymph nodes (SLNs), and detection time of SLNB and evaluated the safety.
RESULTS: The mean age of the MMM group and RI group was 48.2 and 51.0 years (p = 0.12), respectively. There were no differences in histopathologic factors, including tumor size, node positivity, and hormone receptor positivity between groups. SLNs were identified in all patients of both groups (100 % in the MMM group and 100 % in the RI group). The average number of SLNs in the MMM group was more than that in the RI group (3.4 ± 1.37 vs. 2.3 ± 1.04, respectively; p < 0.001). The time to detect the first sentinel lymph node was similar in each group (6.5 ± 5.16 vs. 8.0 ± 4.35 min; p = 0.13). In the MMM group, percutaneous lymphatic drainage was visualized by fluorescent imaging in 90.7 % (39 of 43 patients). During and after the operation, there were no complications, including allergic reactions, skin staining, or necrosis.
CONCLUSIONS: This study is the first randomized trial that compared MMM using ICG, RI, and BD and the conventional RI method for SLNB. MMM is a feasible and safe method for SLNB.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24356798     DOI: 10.1245/s10434-013-3437-0

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  21 in total

1.  Long-term results of fluorescence and indigo carmine blue dye-navigated sentinel lymph node biopsy.

Authors:  Sota Asaga; Ai Tsuchiya; Yoshiharu Ishizaka; Kaisuke Miyamoto; Hiroki Ito; Hirotsugu Isaka; Tomohiro Chiba; Shigeru Imoto; Hiroshi Kamma
Journal:  Int J Clin Oncol       Date:  2021-04-20       Impact factor: 3.402

2.  A Novel Indocyanine Green Fluorescence-Guided Video-Assisted Technique for Sentinel Node Biopsy in Breast Cancer.

Authors:  Luca Sorrentino; Alessandra Sartani; Gaia Pietropaolo; Daniela Bossi; Serena Mazzucchelli; Marta Truffi; Diego Foschi; Fabio Corsi
Journal:  World J Surg       Date:  2018-09       Impact factor: 3.352

Review 3.  Beyond the margins: real-time detection of cancer using targeted fluorophores.

Authors:  Ray R Zhang; Alexandra B Schroeder; Joseph J Grudzinski; Eben L Rosenthal; Jason M Warram; Anatoly N Pinchuk; Kevin W Eliceiri; John S Kuo; Jamey P Weichert
Journal:  Nat Rev Clin Oncol       Date:  2017-01-17       Impact factor: 66.675

4.  Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience.

Authors:  Fatih Aydoğan; Akif Enes Arıkan; Erman Aytaç; Mehmet Velidedeoğlu; Mehmet Halit Yılmaz; Muhammet Sait Sager; Varol Çelik; Cihan Uras
Journal:  Ulus Cerrahi Derg       Date:  2015-08-18

5.  Evaluation of a radioactive and fluorescent hybrid tracer for sentinel lymph node biopsy in head and neck malignancies: prospective randomized clinical trial to compare ICG-(99m)Tc-nanocolloid hybrid tracer versus (99m)Tc-nanocolloid.

Authors:  Ingo Stoffels; Julia Leyh; Thorsten Pöppel; Dirk Schadendorf; Joachim Klode
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-05-31       Impact factor: 9.236

6.  Sentinel lymph node biopsy using indocyanine green fluorescence in early-stage breast cancer: a meta-analysis.

Authors:  Tomoharu Sugie; Takafumi Ikeda; Atsushi Kawaguchi; Akira Shimizu; Masakazu Toi
Journal:  Int J Clin Oncol       Date:  2016-11-19       Impact factor: 3.402

7.  Long-term follow-up results of fluorescence and blue dye guided sentinel lymph node biopsy in early breast cancer.

Authors:  Chaobin Wang; Fuzhong Tong; Yingming Cao; Peng Liu; Bo Zhou; Hongjun Liu; Lin Cheng; Miao Liu; Jiajia Guo; Fei Xie; Houpu Yang; Siyuan Wang; Yuan Peng; Shu Wang
Journal:  Breast Cancer Res Treat       Date:  2021-03-24       Impact factor: 4.872

Review 8.  A review of performance of near-infrared fluorescence imaging devices used in clinical studies.

Authors:  B Zhu; E M Sevick-Muraca
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

Review 9.  Performance of Indocyanine green for sentinel lymph node mapping and lymph node metastasis in colorectal cancer: a diagnostic test accuracy meta-analysis.

Authors:  E Villegas-Tovar; J Jimenez-Lillo; V Jimenez-Valerio; A Diaz-Giron-Gidi; R Faes-Petersen; A Otero-Piñeiro; F B De Lacy; R J Martinez-Portilla; A M Lacy
Journal:  Surg Endosc       Date:  2019-11-21       Impact factor: 4.584

Review 10.  Image-guided tumor surgery: will there be a role for fluorescent nanoparticles?

Authors:  Tanner K Hill; Aaron M Mohs
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2015-11-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.