Literature DB >> 30226955

Evaluation of rapid measurement of Chlamydia trachomatis and Neisseria gonorrhoeae by using automatic gene analyzer "GENECUBE".

Narimi Miyazaki, Yuka Yamagishi, Koji Izumi, Yosuke Kawashima, Hiroyuki Suematsu, Hiroshige Mikamo.   

Abstract

Nucleic acid amplification tests (NAATs) are considered as one of critical diagnostic methods on Chlamydia trachomatis and Neisseria gonorrhoeae infections due to their high sensitivity and accuracy. However, conventional NAATs required 2-6 hours to complete the measurements including extraction, amplification, and detection of the target nucleic acids. To reduce the time, we evaluated the clinical significance of the rapid NAAT using GENECUBE (TOYOBO CO., LTD.) which can complete the measurement within 1 hour. We compared the performance of GENECUBE with those of TMA method (APTIMA" Combo2 chlamydia/ gonorrhoeae, Hologic Japan, Inc.) and lateral flow immunochromatographic assay (Clearview Chlamydia, Clearview gonorrhoeae, Alere Medical Co., Ltd.) by detecting specimens from 96 cervical swabs. The overall agreement results between GENECUBE and TMA were 95.8% and 100% for C. trachomatis and N. gonorrhoeae, respectively. The results suggested that GENECUBE showed equivalent sensitivity and specificity of TMA. Indeed, more than half of the positive samples in NAATs were measured as negative in the lateral flow. The lateral flow is known as a rapid assay, however the results revealed its poor sensitivity. We think rapid NAATs using GENECUBE on C. trachomatis and N. gonorrhoeae can be one of the methods, which realize rapid tests with high sensitivity and accuracy.

Entities:  

Mesh:

Year:  2016        PMID: 30226955

Source DB:  PubMed          Journal:  Jpn J Antibiot        ISSN: 0368-2781


  5 in total

1.  High-Speed Quenching Probe-Polymerase Chain Reaction Assay for the Rapid Detection of Carbapenemase-Producing Gene Using GENECUBE: A Fully Automatic Gene Analyzer.

Authors:  Qi Lu; Takashi Okanda; Yu Yang; Hazim O Khalifa; Anwarul Haque; Hiromu Takemura; Tetsuya Matsumoto
Journal:  Mol Diagn Ther       Date:  2021-01-16       Impact factor: 4.074

2.  A Prospective Evaluation of the Analytical Performance of GENECUBE® HQ SARS-CoV-2 and GENECUBE® FLU A/B.

Authors:  Yoshihiko Kiyasu; Yusaku Akashi; Akio Sugiyama; Yuto Takeuchi; Shigeyuki Notake; Asami Naito; Koji Nakamura; Hiroichi Ishikawa; Hiromichi Suzuki
Journal:  Mol Diagn Ther       Date:  2021-05-18       Impact factor: 4.476

3.  Clinical evaluation of a non-purified direct molecular assay for the detection of Clostridioides difficile toxin genes in stool specimens.

Authors:  Toshinori Hara; Hiromichi Suzuki; Tadatomo Oyanagi; Norito Koyanagi; Akihito Ushiki; Naoki Kawabata; Miki Goto; Yukio Hida; Yuji Yaguchi; Kiyoko Tamai; Shigeyuki Notake; Yosuke Kawashima; Akio Sugiyama; Keiichi Uemura; Seiya Kashiyama; Toru Nanmoku; Satoshi Suzuki; Hiroshi Yamazaki; Hideki Kimura; Hiroyuki Kunishima; Hiroki Ohge
Journal:  PLoS One       Date:  2020-06-03       Impact factor: 3.240

4.  The evaluation of the utility of the GENECUBE HQ SARS-CoV-2 for anterior nasal samples and saliva samples with a new rapid examination protocol.

Authors:  Asami Naito; Yoshihiko Kiyasu; Yusaku Akashi; Akio Sugiyama; Masashi Michibuchi; Yuto Takeuchi; Shigeyuki Notake; Koji Nakamura; Hiroichi Ishikawa; Hiromichi Suzuki
Journal:  PLoS One       Date:  2021-12-31       Impact factor: 3.240

5.  Performance of point-of-care tests for the detection of chlamydia trachomatis infections: A systematic review and meta-analysis.

Authors:  Ying Zhou; Ting-Ting Jiang; Jing Li; Yue-Ping Yin; Xiang-Sheng Chen
Journal:  EClinicalMedicine       Date:  2021-06-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.